Wind power accommodation strategy and benefit analysis of combined heating of electric and coal boilers

被引:0
|
作者
Ge, Weichun [1 ,2 ]
Cheng, Shanshan [2 ]
Sun, Peng [2 ]
Li, Jiajue [3 ]
Shao, Baozhu [3 ]
He, Huan [4 ]
机构
[1] State Grid Liaoning Electric Power Supply Co., Ltd., Shenyang,110004, China
[2] College of Electrical Engineering, Shenyang University of Technology, Shenyang,110870, China
[3] Electrical Power Research Institute of Liaoning Electric Power Co., Ltd., Shenyang,110006, China
[4] State Grid Liaoning Electric Power Supply Co., Ltd., Anshan Electric Power Co., Ltd., Anshan,114000, China
来源
关键词
Coal savings - Comprehensive benefit - Coordinated operation - Economic and environmental benefits - Electric power storage - Energy conversion models - Operational strategies - Wind power accommodations;
D O I
暂无
中图分类号
学科分类号
摘要
Aiming at the large-scale wind-dissipating problems existing in the rapid development of wind power in the Three North region of China, the wind-reduction and dissipation strategy based on combined heat storage of electric heat storage boilers and coal-fired boilers was studied, and a comprehensive benefit analysis model was established. Based on the wind power output and load forecasting data of the power grid operation management department, this paper proposes a wind power calculation model for a certain period of time, and on this basis, studied the electricity-heat of heat storage and heat release by the electric heat storage boiler. An energy conversion model was established to establish an operational strategy for the replacement of coal-fired boilers for heating by abandoning wind power. According to the total heat required by the heating network and the operation strategy of the electric heat storage boiler, the optimal coal-saving operation mode of the coal-fired boiler was studied, and a coordinated operation control strategy for electricity and coal boilers for combined heating and wind rejection was further established. The conversion model between the electric power storage heat-dissipation boiler and the coal consumption of coal-fired boilers under the same heat is studied, and a comprehensive benefit analysis model for the combination of electricity and heat boilers was proposed. The simulation analysis conducted by the wind power heating project example showed that the proposed strategy of combined heating and disposing of wind power for coal and coal boilers can effectively improve the capacity of abandoning wind and dissipate energy, at the same time, it can significantly reduce coal consumption of coal-fired boilers and improve economic and environmental benefits. © 2019, Editorial Board of Acta Energiae Solaris Sinica. All right reserved.
引用
收藏
页码:986 / 994
相关论文
共 50 条
  • [31] Heat-power peak shaving and wind power accommodation of combined heat and power plant with thermal energy storage and electric heat pump
    Wang, Haichao
    Han, Jianbo
    Zhang, Ruoyu
    Sun, Mingyi
    Sun, Zongyu
    Hua, Pengmin
    Xie, Zichan
    Wang, Hai
    Abdollahi, Elnaz
    Lahdelma, Risto
    Granlund, Katja
    Teppo, Esa
    ENERGY CONVERSION AND MANAGEMENT, 2023, 297
  • [32] Combined Operation Mode of Wind Power Enterprises and Regenerative Electric Heating Participating in Frequency Regulation Market
    Yu N.
    He Y.
    Huang D.
    Cui H.
    Zhang Z.
    Jiang M.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2023, 47 (04): : 27 - 33
  • [33] Combined Optimization of District Heating and Electric Power Networks
    Maurer, Jona
    Elsner, Christoph
    Krebs, Stefan
    Hohmann, Soren
    16TH INTERNATIONAL SYMPOSIUM ON DISTRICT HEATING AND COOLING, DHC2018, 2018, 149 : 509 - 518
  • [34] Usage of combined energy storage electric boiler to enhance wind power accommodation based on flexible tolerance polyhedron method
    Lan Z.
    Feng W.
    Hu J.
    Yu J.
    Li S.
    Wei Z.
    Liu B.
    Yu M.
    1600, Electric Power Automation Equipment Press (40): : 47 - 53
  • [35] Improving wind power accommodation of combined heat and power plant based on bypass system
    Wang Z.
    Cao L.
    Dong E.
    Hu P.
    Liu M.
    Ma T.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2021, 42 (01): : 317 - 323
  • [36] Review of Optimal Dispatching of Combined Heat-Power System for Wind Power Accommodation
    Cui, Dai
    Jiang, Di
    Jiang, YuQing
    Ge, Wei Chun
    Cong, HaiYang
    He, ChaoJun
    Li, Feng
    2019 5TH INTERNATIONAL CONFERENCE ON ENVIRONMENTAL SCIENCE AND MATERIAL APPLICATION, 2020, 440
  • [37] Thermoeconomic analysis of a coal-fired power plant combined with district heating and cooling
    Ziher, Dejan
    Poredos, Alojz
    ECOS 2006: PROCEEDINGS OF THE 19TH INTERNATIONAL CONFERENCE ON EFFICIENCY, COST, OPTIMIZATION, SIMULATION AND ENVIRONMENTAL IMPACT OF ENERGY SYSTEMS, VOLS 1-3, 2006, : 1261 - +
  • [38] Optimal Operation Strategy for Wind-Hydrogen-Water Power Grids Facing Offshore Wind Power Accommodation
    Liu, Zhen
    Wang, He
    Zhou, Bowen
    Yang, Dongsheng
    Li, Guangdi
    Yang, Bo
    Xi, Chao
    Hu, Bo
    SUSTAINABILITY, 2022, 14 (11)
  • [39] Study on the Optimal Dispatching Strategy of a Combined Cooling, Heating and Electric Power System Based on Demand Response
    Zhao, Ye
    Dou, Zhenhai
    Yu, Zexu
    Xie, Ruishuo
    Qiao, Mengmeng
    Wang, Yuanyuan
    Liu, Lianxin
    ENERGIES, 2022, 15 (10)
  • [40] Integrating wind power using intelligent electric water heating
    Fitzgerald, Niall
    Foley, Aoife M.
    McKeogh, Eamon
    ENERGY, 2012, 48 (01) : 135 - 143