The value of ultrasound in combination with 99mTc-MIBI imaging department of ultrasound medicine, for the diagnosis of ectopic parathyroid glands in the thyroid gland in patients with secondary hyperparathyroidism

被引:1
|
作者
Zhao, Bingxin [1 ]
Chen, Simei [1 ]
Zang, Jiangnan [2 ]
Wang, Xinying [1 ]
Dai, Xinpeng [1 ]
Liu, Zongjie [1 ]
Xie, Peng [3 ]
Wang, Xiaoyan [4 ]
Wang, Shuchang [5 ]
Gao, Feng [6 ]
Sui, Xin [1 ]
机构
[1] Hebei Med Univ, Dept Ultrasound Med, Hosp 3, 139,Ziqiang Rd, Shijiazhuang 050051, Hebei, Peoples R China
[2] Hebei Med Univ, Shijiazhuang, Hebei, Peoples R China
[3] Hebei Med Univ, Hosp 3, Dept Nucl Med, Shijiazhuang, Hebei, Peoples R China
[4] Hebei Prov Hosp Tradit Chinese Med, Dept Ultrasound Med, Shijiazhuang, Hebei, Peoples R China
[5] Hebei Med Univ, Dept Endocrinol, Hosp 3, Shijiazhuang, Hebei, Peoples R China
[6] Hebei Med Univ, Dept Pathol, Hosp 3, Shijiazhuang, Hebei, Peoples R China
关键词
Tc-99m-MIBI imaging; ectopic intrathyroid parathyroid gland; ectopic parathyroid; secondary hyperparathyroidism; ultrasound; LOCATION;
D O I
10.1097/MD.0000000000037866
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To investigate the value of preoperative ultrasound combined with(99m)Tc-MIBI imaging for the diagnosis of ectopic intrathyroid parathyroid gland (ETPG) in patients with secondary hyperparathyroidism (SHPT). One hundred and eleven patients with SHPT who underwent total parathyroidectomy plus forearm transplantation from January 2015 to January 2022 in the Third Hospital of Hebei Medical University were selected. All patients underwent routine preoperative ultrasonography and Tc-99m-MIBI imaging, and with pathological diagnosis as the gold standard, the clinical data of ETPG patients were selected, including clinical manifestations, laboratory tests, preoperative ultrasonography and Tc-99m-MIBI imaging for localization and diagnosis, intraoperative exploration and postoperative pathology, and postoperative follow-up. To analyze the ultrasound manifestations of preoperative parathyroid hyperplasia and the results of Tc-99m-MIBI imaging in patients with ETPG. Among 111 patients with SHPT, there were 5 patients with ETPG, 1 male and 4 females with a mean age of (45.00 +/- 5.05) years, and 6 ectopic parathyroid glands were located in the thyroid gland. The incidence of ETPG was 4.5% (5/111), 4 were detected by ultrasound, 2 were not detected with a diagnostic accuracy of 66.7% (4/6), 3 were positive for Tc-99m-MIBI imaging, 3 were negative with a diagnostic accuracy of 50.0% (3/6). Among them, one was not detected by ultrasound, but was positive for Tc-99m-MIBI imaging, 2 with negative Tc-99m-MIBI imaging, but all were detected by ultrasound, and one with negative Tc-99m-MIBI imaging was detected by ultrasound but misdiagnosed as a thyroid nodule. A total of 5 ETPGs were detected by ultrasound combined with Tc-99m-MIBI imaging, with a diagnostic accuracy of 83.3% (5/6). Patients' postoperative serum calcium and serum parathyroid hormone (PTH) levels were normalized or significantly decreased from preoperative levels. Ultrasound combined with Tc-99m-MIBI imaging can achieve higher accuracy than either examination alone in the preoperative localization and diagnosis of ETPG in SHPT patients.
引用
收藏
页数:7
相关论文
共 36 条
  • [21] The incremental value of 99mTc-pertechnetate thyroid imaging for the evaluation of parathyroid disease with dual phase 99mTc-MIBI scintigraphy.
    Yudd, AP
    Kempf, JS
    Becker, MD
    Amorosa, LF
    Saul, JM
    JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (05) : 311P - 311P
  • [22] Ultrasound guided percutaneous microwave ablation of hypofunctional thyroid nodules: evaluation by scintigraphic 99mTc-MIBI imaging
    Korkusuz, H.
    Happel, C.
    Gruenwald, F.
    NUKLEARMEDIZIN-NUCLEAR MEDICINE, 2013, 52 (06): : N68 - N68
  • [23] Incremental value of 99mTc-MIBI single-photon emission computed tomography/computed tomography fusion imaging for the diagnosis of secondary hyperparathyroidism
    Peng, Ye
    Pan, Guixia
    Zhao, Bo
    Zuo, Changjing
    Wang, Yingqiu
    Chen, Rui
    NUCLEAR MEDICINE COMMUNICATIONS, 2023, 44 (09) : 767 - 771
  • [24] Combination of 99mTc-MIBI Scintigraphy, Fine Needle Aspiration and Ultrasound in the Preoperative Assessment of Patients With Hypofunctioning Solitary Thyroid Nodules (HSTN)
    Kanaev, S.
    Novikov, S.
    Djalilov, D.
    Moiseenko, V.
    Krasilnikova, L.
    Kostromina, E.
    Jukova, L.
    EUROPEAN JOURNAL OF CANCER, 2011, 47 : S211 - S211
  • [25] Added value of collegial interpretation of cervical ultrasound, 99mTc-MIBI scintigraphy and 18-Fluorocholine PET-CT in primary hyperparathyroidism: Experience of the nuclear medicine department of Cochin Hospital
    Mekhail, S.
    Dudoignon, D.
    Delbot, T.
    Cottereau, A. S.
    Dechmi, A.
    Bienvenu, M.
    Koumakis, E.
    Cormier, C.
    Gaujoux, S.
    Groussin, L.
    MEDECINE NUCLEAIRE-IMAGERIE FONCTIONNELLE ET METABOLIQUE, 2022, 46 (03): : 146 - 155
  • [26] Lesion based diagnostic performance of dual phase 99mTc-MIBI SPECT/CT imaging and ultrasonography in patients with secondary hyperparathyroidism
    Panli Li
    Qiufang Liu
    Daoqiang Tang
    Yinyan Zhu
    Lian Xu
    Xiaoguang Sun
    Shaoli Song
    BMC Medical Imaging, 17
  • [27] Lesion based diagnostic performance of dual phase 99mTc-MIBI SPECT/CT imaging and ultrasonography in patients with secondary hyperparathyroidism
    Li, Panli
    Liu, Qiufang
    Tang, Daoqiang
    Zhu, Yinyan
    Xu, Lian
    Sun, Xiaoguang
    Song, Shaoli
    BMC MEDICAL IMAGING, 2017, 17
  • [28] 99mTc-MIBI SPECT/CT imaging had high sensitivity in accurate localization of parathyroids before parathyroidectomy for patients with secondary hyperparathyroidism
    Zeng, Ming
    Liu, Wei
    Zha, Xiaoming
    Tang, Shaowen
    Liu, Jin
    Yang, Guang
    Mao, Huijuan
    Yu, Xiangbao
    Sun, Bin
    Zhang, Bo
    Ouyang, Chun
    Zhang, Lina
    Guo, Jing
    Wang, Jing
    Huan, Yaoyu
    Purrunsing, Yogendranath
    Qian, Hanyang
    Wang, Ningning
    Xing, Changying
    RENAL FAILURE, 2019, 41 (01) : 885 - 892
  • [29] Does reporting of 99mTc-MIBI Parathyroid scan influence final intraoperative decision and reflect the histology of secondary hyperparathyroidism in chronic renal failure patients? (Our experience)
    Kolindou, A.
    Kitsou, E.
    Bokos, I.
    Zavos, G.
    Deladetsima, F.
    Kostakis, A.
    Kyriaki-Manolaraki, D.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 : S233 - S233
  • [30] The role of preoperative ultrasound, contrast-enhanced ultrasound, and 99mTc-MIBI scanning with single-photon emission computed tomography/X-ray computed tomography localization in refractory secondary hyperparathyroidism
    Li, XiuMei
    Li, Jun
    Li, Yong
    Wang, HongQiao
    Yang, JingRu
    Mou, Shuang
    Zhou, MaoPing
    Jiang, CaiYun
    Ning, ChunPing
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2020, 75 (01) : 35 - 46