Fast DC-link voltage control based on power flow management using linear ADRC combined with hybrid salp particle swarm algorithm for PV/wind energy conversion system

被引:9
|
作者
AL-Wesabi, Ibrahim [1 ,2 ,3 ]
Zhijian, Fang [1 ,2 ,3 ]
Jiuqing, Cai [4 ]
Farh, Hassan M. Hussein [5 ]
Aboudrar, Imad [6 ]
Dagal, Idriss [7 ]
Kandil, Tarek [8 ]
Al-Shamma'a, Abdulrahman A. [5 ]
Saeed, Fahman [9 ]
机构
[1] China Univ Geosci, Sch Automat, Wuhan 430074, Peoples R China
[2] Hubei Key Lab Adv Control & Intelligent Automat Co, Wuhan, Peoples R China
[3] Minist Educ, Engn Res Ctr Intelligent Technol Geoexplorat, Wuhan 430074, Peoples R China
[4] Wuhan Second Ship Design & Res Inst, Wuhan, Peoples R China
[5] Imam Mohammad Ibn Saud Islamic Univ, Elect Engn Dept, Riyadh, Saudi Arabia
[6] Ibn Zohr Univ, Engn & Sustainable Dev Res Team, EST Dakhla, Dakhla, Morocco
[7] Yildiz Tech Univ, Fac Elect Engn, Istanbul, Turkiye
[8] Western Carolina Univ, Sch Engn, Cullowhee, NC 28723 USA
[9] Imam Mohammad Ibn Saud Islamic Univ, Comp Sci Dept, Riyadh 11564, Saudi Arabia
关键词
Active disturbance rejection controller (ADRC); (PV/WECS); Hybrid SPSA-MPPT techniques; DC-Link voltage managements; ARTIFICIAL BEE COLONY; POINT TRACKING; PHOTOVOLTAIC SYSTEMS; PV SYSTEMS; FUEL-CELL; OPTIMIZATION; MPPT; BATTERY;
D O I
10.1016/j.ijhydene.2024.02.325
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Hybrid Energy Systems (HESs) are offering several advantages over conventional generation systems because of the rising need for Renewable Energy Resources (RERs) and its high capability and flexibility of achieving the desired performance for both urban and rural areas. The main goals of HESs are to improve the system performance by increasing its flexibility, reliability and reducing generation instability. In the current work, a hybrid Photovoltaic/Wind Energy Conversion System (PV/WECS) is proposed to supply and support the utility grid. The generated power from the system is greatly responding to the change in both the wind speed and PV irradiance level, and as a result impacting the DC-Bus voltage of the system converters. Therefore, precise, fast and optimum controllers are required for the PV/WECS system to ensure the extraction and generation of stable maximum power during weather variations along with maintaining the DC-Link voltage at the desired value. Further, this study proposes a novel Linear Active Disturbance Rejection Control (LADRC) combined with a hybrid Salp Particle Swarm Algorithm (SPSA) to a grid-connected PV/WECS for extracting the Global Maximum Power (GMP), regulating the DC-Link voltage, and enhancing the active and reactive powers control. The capability of the proposed SPSA-LADRC based-MPPT approach is examined according to the tracking time, accuracy and response to internal and external disturbances and then comparing its performance with other techniques such as SPSA-SMC, SPSA-PID and SPSA-PI controllers respectively. The findings revealed that the LADRC can track and keep the DC-Link voltage as the desired reference value,1500 V, respond much faster than the PI, SMC, and PID controllers as well as keep the THD of the injected current into the grid at a low level of 2.25%. Finally, the performance of the proposed system is experimentally verified using Hardware-In-Loop (HIL). The obtained findings verify the capability and accuracy of the system and its great potential in the management of HESs.
引用
收藏
页码:688 / 709
页数:22
相关论文
共 50 条
  • [41] Maximum power point tracking control and voltage regulation of a DC grid-tied wind energy conversion system based on a novel permanent magnet reluctance generator
    Raza, Kazmi Syed Muhammad
    Goto, Hiroki
    Guo, Hai-Jiao
    Ichinokura, Osamu
    2007 INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS 1-4, 2007, : 1732 - +
  • [42] DC-Bus Voltage Control of MPPT-based Wind Generation System Using Hybrid BESS-SMES System for Pulse Loads in Ship Power Applications
    Elmorshedy, Mahmoud
    Amin, Mahmoud M.
    El-Sousy, Fayez F. M.
    Mohammed, Osama A.
    2021 THIRTY-SIXTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC 2021), 2021, : 76 - 82
  • [43] Distributed energy storage system-based nonlinear control strategy for hybrid microgrid power management included wind/PV units in grid-connected operation
    Holari, Yaser Toghani
    Taher, Seyed Abbas
    Mehrasa, Majid
    INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2020, 30 (02)
  • [44] Retraction Note to: An AC–DC/DC–DC hybrid multi-port embedded energy router based steady-state power flow optimizing in power system using substantial transformative energy management strategy
    B. Tharani
    C. Nagarajan
    Journal of Ambient Intelligence and Humanized Computing, 2023, 14 (Suppl 1) : 187 - 187
  • [45] RETRACTED ARTICLE: An AC–DC/DC–DC hybrid multi-port embedded energy router based steady-state power flow optimizing in power system using substantial transformative energy management strategy
    B. Tharani
    C. Nagarajan
    Journal of Ambient Intelligence and Humanized Computing, 2021, 12 : 5687 - 5707
  • [46] Robustification of the H∞ controller combined with fuzzy logic and PI&PID-Fd for hybrid control of Wind Energy Conversion System Connected to the Power Grid Based on DFIG
    Wadawa, Boaz
    Errami, Youssef
    Obbadi, Abdellatif
    Sahnoun, Smail
    ENERGY REPORTS, 2021, 7 : 7539 - 7571
  • [47] Fuzzy SVPWM-based inverter control realisation of grid integrated photovoltaic-wind system with fuzzy particle swarm optimisation maximum power point tracking algorithm for a grid-connected PV/wind power generation system: hardware implementation
    Priyadarshi, Neeraj
    Padmanaban, Sanjeevikumar
    Bhaskar, Mahajan Sagar
    Blaabjerg, Frede
    Sharma, Amarjeet
    IET ELECTRIC POWER APPLICATIONS, 2018, 12 (07) : 962 - 971
  • [48] Maximum Power Point Tracking-Based Control Strategy for PMSG Wind Energy Conversion System Using a Combined Fuzzy-Model Predictive Controller
    Akbari, Ehsan
    Shadlu, Milad Samady
    2023 14TH POWER ELECTRONICS, DRIVE SYSTEMS, AND TECHNOLOGIES CONFERENCE, PEDSTC, 2023,
  • [49] Optimal Power Management and Control of Hybrid Photovoltaic-Battery for Grid-Connected Doubly-Fed Induction Generator Based Wind Energy Conversion System
    Nasef, Sahar A.
    Hassan, Amal A.
    ElMadany, Hanaa T.
    Zahran, Mohamed B.
    El-Shaer, Mohamed K.
    Abdelaziz, Almoataz Y.
    INTERNATIONAL JOURNAL OF RENEWABLE ENERGY RESEARCH, 2022, 12 (01): : 408 - 421
  • [50] Robust operating strategy for voltage and frequency control in a non-linear hybrid renewable energy-based power system using communication time delay
    Irfan, Rasmia
    Gulzar, Muhammad Majid
    Shakoor, Adnan
    Habib, Salman
    Ahmad, Hasnain
    Hasib, Shahid A.
    Tehreem, Huma
    COMPUTERS & ELECTRICAL ENGINEERING, 2025, 123