Discrepancy between arterial oxygen saturation and pulse oximetry measurement in a Chinese pediatric patient cohort

被引:0
|
作者
Chen, Qin-chang [1 ]
Shen, Jun-jun [1 ]
Huang, Yu-lu [1 ]
Kong, Ran [1 ]
Xie, Yu-mei [1 ]
Wang, Shu- shui [1 ]
机构
[1] Southern Med Univ, Guangdong Prov Peoples Hosp, Guangdong Acad Med Sci, Dept Pediat Cardiol, Guangzhou 510000, Peoples R China
关键词
Oximetry; Oxygen saturation; Racial groups; Occult hypoxemia; Pediatrics; SKIN PIGMENTATION; ACCURACY; RELIABILITY;
D O I
10.1016/j.heliyon.2024.e28336
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background: Increasing evidence suggest a racial bias in pulse oximetry measurement, but this was under investigated in Asian pediatric populations. Methods: Via the Pediatric Intensive Care database, this retrospective study included pediatric patient records of arterial oxygen saturation (SaO(2)) and oxygen saturation on pulse oximetry (SpO(2)) measured within 10 min. Discrepancy was examined, and potential predictors of occult hypoxemia (defined as SaO(2) <88% with the paired SpO(2) >= 92%) as well as its association with outcomes were explored by logistic regression. Results: A total of 390 patients were included with 454 pairs of SaO(2)-SpO(2) readings. The study population consisted of Han Chinese (99.0%) and 43.6% were female. Occult hypoxemia was observed in 20.0% of the patients, with a mean SaO(2) of 71.4 +/- 15.8%. Potential predictors of occult hypoxemia included female, being first admitted to cardiac ICU, congenital heart disease, increased heart rate, while patients with prior surgery records were less likely to experience occult hypoxemia. Patients with occult hypoxemia had numerically higher in-ICU mortality (16.7% versus 10.9%) and in-hospital mortality (17.9% versus 10.9%), but the associations were not statistically significant. Conclusions: There was a substantial proportion of hypoxemia that was not detected by pulse oximetry in the Chinese pediatric patients, which might be predicted by several characteristics and seemed to associate with mortality.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Discrepancy Between Pulse Oximetry And Arterial Oxygen Saturation At Rest And During Exercise
    Bhattacharyya, A.
    Ramos, J.
    Tonelli, A. R.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2017, 195
  • [2] Measurement of arterial oxygen-haemoglobin saturation in newborn lambs by pulse oximetry
    Norton, JR
    Jackson, PGG
    Taylor, PM
    VETERINARY RECORD, 1998, 142 (05) : 107 - 109
  • [3] MONITORING OF ARTERIAL OXYGEN-SATURATION BY PULSE OXIMETRY
    STRIEBEL, HW
    STEINHOFF, U
    KRETZ, FJ
    ANASTHESIOLOGIE & INTENSIVMEDIZIN, 1988, 29 (01): : 8 - 16
  • [4] Discrepancies between Arterial Oxygen Saturation and Functional Oxygen Saturation Measured with Pulse Oximetry in Very Preterm Infants
    Rosychuk, Rhonda J.
    Hudson-Mason, Ann
    Eklund, Dianne
    Lacaze-Masmonteil, Thierry
    NEONATOLOGY, 2012, 101 (01) : 14 - 19
  • [5] Arterial Oxygen Saturation, Pulse Oximetry, and Cerebral and Tissue Oximetry in Hypobaric Hypoxia
    Ottestad, William
    Kasin, Jan Ivar
    Hoiseth, Lars Oivind
    AEROSPACE MEDICINE AND HUMAN PERFORMANCE, 2018, 89 (12) : 1045 - 1049
  • [6] MONITORING OF ARTERIAL OXYGEN-SATURATION BY PULSE OXIMETRY - COMMENT
    SALEM, CJ
    JANDA, A
    BERGER, M
    BRANDSTETTER, A
    ANASTHESIOLOGIE & INTENSIVMEDIZIN, 1988, 29 (10): : 293 - 293
  • [7] FETAL OXYGEN-SATURATION MEASUREMENT BY TRANSMISSION PULSE OXIMETRY
    BUSCHMANN, J
    RALL, G
    KNITZA, R
    LANCET, 1992, 339 (8793): : 615 - 615
  • [8] Blood haemoglobin and pulse oximetry oxygen saturation measurement error
    Crooks, C.
    West, J.
    Morling, J.
    Simmonds, M.
    Juurlink, I.
    Briggs, S.
    Cruickshank, S.
    Hammond-Pears, S.
    Shaw, D.
    Card, T.
    Fogarty, A.
    EUROPEAN RESPIRATORY JOURNAL, 2022, 60
  • [9] BIOLOGICAL QUALITY CONTROL FOR PULSE OXIMETRY OXYGEN SATURATION MEASUREMENT
    Back, Geraldine M.
    Dooney, Natalie A.
    Robiony-Rogers, David
    RESPIROLOGY, 2012, 17 : 7 - 7
  • [10] EVALUATION OF EAR OXIMETRY IN THE MEASUREMENT OF ARTERIAL OXYGEN-SATURATION
    CABLE, JA