Structural Behavior of Concrete One-Way Slab with Mixed Reinforcement of Steel and Glass Fiber Polymer Bars under Fire Exposure

被引:0
|
作者
Rasheed, Mohammed R. [1 ]
Mohammed, Shatha D. [1 ]
机构
[1] Univ Baghdad, Engn Coll, Dept Civil Engn, Baghdad, Iraq
关键词
reinforced concrete slabs; fire resistance; Glass Fiber-Reinforced Polymer (GFRP); concrete cover; RC BEAMS;
D O I
10.48084/etasr.6795
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Steel Reinforced Concrete (RC) frequently faces durability problems. In certain areas, Glass FiberReinforced Polymer (GFRP) rebars are considered a non-corrodible substitute for steel reinforcement. Elevated temperatures have a significant impact on the mechanical characteristics and the adhesiveness of GFRP rebars to concrete, particularly when the polymeric matrix's glass transition temperature is approached or surpassed. Three simply supported reinforced concrete slabs were considered in the experimental program. Each specimen had identical dimensions of 1500x540x120 mm. For the fire resistance requirements, a 45 mm clear concrete cover and an exception of a 200 mm unexposed (cool) anchor zone at the ends were considered. The GFRP replacement ratio was 0, 20, and 40%. The burning procedure involved fire exposure for an hour with a steady-state temperature of 500 degrees C in accordance with ASTM E-119 regarding the temperature time elevation and a sudden cooling condition. The optimal concrete cover was detected by testing a fire-exposed small model reinforced by GFRP bars of varying concrete cover. The specimen was tested under static intense loads. The reference slab and the slab with a replacement percentage of 20% failed due to flexural failure, whereas the slab with a replacement percentage of 40% failed due to shear failure. The influence of the GFRP replacement ratio was extended to include toughness and ultimate load. A replacement percent of 20% increased them by 18.30, and 2.62%, respectively, while a replacement percent of 40% decreased them by 28.16, and 3.13%, accordingly. It was also shown that the location of replacing the GFRP and 200 mm of unexposed (cold) installation area at the ends with a 45 mm concrete cover has a significant impact. The more the GFRP is located in the middle, away from the ends, the better the fire resistance is.
引用
收藏
页码:13380 / 13387
页数:8
相关论文
共 50 条
  • [41] Punching Shear Behavior of Two-Way Concrete Slabs Reinforced with Glass-Fiber-Reinforced Polymer (GFRP) Bars
    Ju, Minkwan
    Park, Kyoungsoo
    Park, Cheolwoo
    POLYMERS, 2018, 10 (08)
  • [42] Does the use of FRP reinforcement change the one-way shear behavior of reinforced concrete slabs?
    Hoult, N. A.
    Sherwood, E. G.
    Bentz, E. C.
    Collins, M. P.
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2008, 12 (02) : 125 - 133
  • [43] Glass Fiber-Reinforced Polymer Bars as Shear-Friction Reinforcement for Concrete Cold Joints
    Aljada, Basel H.
    El Ragaby, Amr
    El-Salakawy, Ehab F.
    ACI STRUCTURAL JOURNAL, 2024, 121 (06) : 47 - 60
  • [44] Numerical analysis of simply supported one-way reinforced concrete slabs under fire condition
    Ding, Fa-xing
    Wang, Wenjun
    Jiang, Binhui
    Wang, Liping
    Liu, Xuemei
    COMPUTERS AND CONCRETE, 2021, 27 (04): : 355 - 367
  • [45] Flexural performance of reinforced concrete one-way slabs strengthened with fiber reinforced polymer sheets
    Gao, Danying
    Zhang, Pu
    Zhang, Changhui
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2015, 36 (07): : 51 - 58
  • [46] Structural Behavior of Composite Reinforced Concrete One-Way Slabs Voided with Plastic Bubbles
    Ibrahim, Amer M.
    Ali, Ibrahim A.
    Ali, Rouaida H.
    CONSTRUCTION RESEARCH CONGRESS 2022: PROJECT MANAGEMENT AND DELIVERY, CONTRACTS, AND DESIGN AND MATERIALS, 2022, : 524 - 534
  • [47] Effective Moment of Inertia of Reinforced Concrete and Reinforced Steel Fiber-Reinforced Concrete One-Way Slabs
    Lee, Jung
    Kim, Kyungchan
    Lee, Chadon
    Lee, Songhee
    ACI STRUCTURAL JOURNAL, 2024, 121 (06) : 19 - 32
  • [48] Punching shear behavior of steel fiber reinforced recycled coarse aggregate concrete two-way slab without shear reinforcement
    Yan, Yongming
    Gao, Danying
    Luo, Feifei
    FRONTIERS OF STRUCTURAL AND CIVIL ENGINEERING, 2024, 18 (10): : 1556 - 1575
  • [49] Behavior of one-way steel, BFRP, and GFRP reinforced concrete slabs under monotonic and cyclic loadings: Experiments and analyses
    Cao, Vui Van
    CASE STUDIES IN CONSTRUCTION MATERIALS, 2024, 21
  • [50] Structural Performance of Lightweight Aggregate Concrete Reinforced by Glass or Basalt Fiber Reinforced Polymer Bars
    Abed, Mohammed A.
    Anagreh, Aysha
    Tosic, Nikola
    Alkhabbaz, Ola
    Alshwaiki, Majd Eddin
    Cerny, Robert
    POLYMERS, 2022, 14 (11)