Constructal design of three fins inside a lid-driven cavity

被引:3
|
作者
Rodrigues, Priscila Martta [1 ]
de Escobar, Cicero Coelho [2 ]
Zinani, Flavia Schwarz Franceschini [3 ]
dos Santos, Elizaldo Domingues [4 ]
Isoldi, Liercio Andre [4 ]
Rocha, Luiz Alberto Oliveira [5 ]
机构
[1] Univ Vale Rio Dos Sinos UNISINOS, Mech Engn Grad Program, Ave Unisinos 950, BR-93022000 Sao Leopoldo, Brazil
[2] Univ Fed Pelotas UFPel, Engn Ctr, Pelotas, RS, Brazil
[3] Univ Fed Rio Grande Do Sul UFRGS, Inst Hydraul Res, Ave Bento Goncalves 9500, BR-91501970 Porto Alegre, Brazil
[4] Univ Fed Rio Grande FURG, Grad Program Comput Modeling, Ave Italia,Km 8, BR-96203900 Rio Grande, RS, Brazil
[5] Univ Fed Rio Grande Do Sul UFRGS, Mech Engn Grad Program, Rua Sarmento Leite 425, BR-90040001 Porto Alegre, RS, Brazil
关键词
Constructal design; Lid-driven flows; Cavity; Mixed convection; Rectangular fins; CONVECTION HEAT-TRANSFER; MIXED-CONVECTION; SQUARE CAVITY; NATURAL-CONVECTION; ENCLOSURE; NUMBER; FLOW; SIMULATION; SURFACES; LAMINAR;
D O I
10.1007/s40430-024-04991-y
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
This study investigates the heat transfer between three fins in the bottom of a lid-driven cavity and the flowing fluid to find the best designs to improve heat transfer and to understand the role of geometric parameters on the system's thermal performance. The constructal design method and the exhaustive search are employed to evaluate the system and to guide the maximization of the dimensionless heat transfer rate, based on a set of numerical results. The numerical model for the flow system assumes steady, incompressible, laminar, and two-dimensional flow with stable stratification conditions. Prandtl, Richardson, and Reynolds's numbers were equal to 6.0, 0.1, and 400, respectively. The conservation equations of mass, momentum, and energy were solved with the finite volume method (FVM). The fraction of area occupied by the three fins was kept constant (phi(T) = 0.1) and two scenarios were studied (phi(1 )= 0.05, phi(2) = 0.04, phi(3) = 0.01 and phi(1) = 0.01, phi(2) = 0.04, phi(3) = 0.05). The best performance was achieved when the fin 3 had the largest area and the highest H-3/L-3 ratio. The results suggest that fin 3 dominance enhances thermal exchange, particularly for higher H-3/L-3 ratios, while fin 2 predominance is observed for lower H-3/L-3 ratios. The optimal geometry was identified as H-1/L-1 = 0.1, (H-2/L-2)(o) = 0.5, and (H-3/L-3)(oo) = 19.0, resulting in the highest heat transfer rate for the configuration phi(1) = 0.05, phi(2) = 0.04, and phi(3) = 0.01. The best-performing geometry investigated was H-1/L-1 = 0.1, (H-2/L-2)(o) = 0.5, and (H-3/L-3)(oo) = 19.0, (q ') over tilde mm = 22.8491, which is 63.9% better than the worst geometry (H-1/L-1 = 0.1, H-2/L-2 = 0.5, and H-3/L-3 = 5.0).
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Lid-driven cavity flow of sediment suspension
    Chuong Nguyen Hoang-Trong
    Cuong Mai Bui
    Thinh Xuan Ho
    EUROPEAN JOURNAL OF MECHANICS B-FLUIDS, 2021, 85 : 312 - 321
  • [22] Fluid-structure interaction of a thin flexible heater inside a lid-driven cavity
    Smriti, Rabeya Bosry
    Das, Arpita
    Mahmood, Fahim Tanfeez
    Hasan, Mohammad Nasim
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2024, 238 (01) : 75 - 93
  • [23] Lid-driven cavity with heat and mass transport
    Alleborn, N
    Raszillier, H
    Durst, F
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1999, 42 (05) : 833 - 853
  • [24] Compressible modes in a square lid-driven cavity
    Bergamo, Leandro F.
    Gennaro, Elmer M.
    Theofilis, Vassilis
    Medeiros, Marcello A. F.
    AEROSPACE SCIENCE AND TECHNOLOGY, 2015, 44 : 125 - 134
  • [25] Global flow instability in a lid-driven cavity
    Boppana, V. B. L.
    Gajjar, J. S. B.
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN FLUIDS, 2010, 62 (08) : 827 - 853
  • [26] CHARACTERISTICS OF LID-DRIVEN OSCILLATORY CAVITY FLOW
    KAJIUCHI, T
    SHIRAGAMI, N
    OHTA, T
    KAGAKU KOGAKU RONBUNSHU, 1986, 12 (04) : 486 - 488
  • [27] MIXED CONVECTION IN A LID-DRIVEN CAVITY FILLED BY A MICROPOLAR NANOFLUID WITH AN INSIDE CIRCULAR CYLINDER
    Raizah, Z. A. S.
    HEAT TRANSFER RESEARCH, 2019, 50 (10) : 921 - 943
  • [28] Enhanced thermal energy transport using adiabatic block inside lid-driven cavity
    Biswas, Nirmalendu
    Manna, Nirmal K.
    Mahapatra, Pallab Sinha
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2016, 100 : 407 - 427
  • [29] Lid-driven cavity flow of viscoelastic liquids
    Sousa, R. G.
    Poole, R. J.
    Afonso, A. M.
    Pinho, F. T.
    Oliveira, P. J.
    Morozov, A.
    Alves, M. A.
    JOURNAL OF NON-NEWTONIAN FLUID MECHANICS, 2016, 234 : 129 - 138
  • [30] Moffatt vortices in the lid-driven cavity flow
    Biswas, Sougata
    Kalita, Jiten C.
    XXVII IUPAP CONFERENCE ON COMPUTATIONAL PHYSICS (CCP2015), 2016, 759