Performance testing of gas-tight portable RPC for muography applications

被引:1
|
作者
Kumar, V. [1 ]
Basnet, S. [1 ]
Gil, E. Cortina [1 ]
Demin, P. [1 ]
Gamage, R. M. I. D. [1 ]
Giammanco, A. [1 ]
Karnam, R. [2 ]
Moussawi, M. [1 ]
Samalan, A. [3 ]
Tytgat, M. [3 ,4 ]
Youssef, A. [5 ]
机构
[1] Univ Catholic Louvain, Ctr Cosmol Particle Phys & Phenomenol CP3, Chemin Cyclotron 2, B-1348 Louvain La Neuve, Belgium
[2] Natl Inst Sci Educ & Res NISER, Ctr Med & Radiat Phys CMRP, Khurja 752050, Odisha, India
[3] Univ Ghent, Dept Phys & Astron, Proeftuinstr 86,N3, B-9000 Ghent, Belgium
[4] Vrije Univ Brussel, Phys Dept, Pl Laan 2, B-1050 Brussels, Belgium
[5] Lebanese Univ, Fac Sci, Multidisciplinary Phys Lab, Opt & Fiber Opt Grp, Hadath Campus St 1, Hadath, Lebanon
关键词
Detector design and construction technologies and materials; Gaseous imaging and tracking detectors; Particle tracking detectors (Gaseous detectors); Resistive-plate chambers;
D O I
10.1088/1748-0221/19/04/C04027
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This paper reports the latest developmental efforts for a position -sensitive glass -based Resistive Plate Chamber (RPC) and a multi -channel Data AcQuisition (DAQ) system tailored for muon tracking in muography applications. The designed setup prioritizes portability, aiming for field applications where both the detector and the DAQ operate effectively in external environmental conditions. Comprehensive discussions on hardware development activities and signal processing techniques are included, incorporating noise filtering to enhance the accurate detection of real muons. A muon absorption measurement has also been carried out to understand the behavior of these detectors from an application perspective.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] COMPARISONS OF SILAGES STORED IN GAS-TIGHT SILOS AND IN CONVENTIONAL SILOS
    SHEPHERD, JB
    GORDON, CH
    WISEMAN, HG
    MELIN, CG
    CAMPBELL, LE
    ROANE, GD
    JOURNAL OF DAIRY SCIENCE, 1953, 36 (11) : 1190 - 1200
  • [42] Optimizing Preloading Pressure of Precharged Gas for Isobaric Gas-Tight Hydrothermal Samplers
    Huang, Haocai
    Huang, Liang
    Ye, Wei
    Wu, Shijun
    Yang, Canjun
    Chen, Ying
    Wang, Hangzhou
    JOURNAL OF PRESSURE VESSEL TECHNOLOGY-TRANSACTIONS OF THE ASME, 2018, 140 (02):
  • [43] TECHNIQUE OF SEALING A SMALL SPECIMEN IN A GAS-TIGHT ALUMINA CRUCIBLE
    NAKAGAWA, Y
    NAKAMURA, SI
    JAPANESE JOURNAL OF APPLIED PHYSICS, 1968, 7 (12) : 1539 - &
  • [44] Synthesis of simulated fuels containing CsI under gas-tight condition
    Liu, J. Z.
    Miwa, S.
    Nakajima, K.
    Osaka, M.
    NUCLEAR MATERIALS AND ENERGY, 2021, 26
  • [45] New elastic gas-tight heat-resistant polymer materials
    Ronkin, G.M.
    Gazovaya Promyshlennost, 2002, (11): : 78 - 80
  • [46] Detector developments for high performance Muography applications
    Varga, D.
    Nyitrai, G.
    Hamar, G.
    Galgoczi, G.
    Olah, L.
    Tanaka, H. K. M.
    Ohminato, T.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 958
  • [47] A New Deep-Sea Gas-Tight Isobaric Water Sampler
    Liu, Heng
    Li, Haojie
    Long, Jingchang
    Jin, Huajie
    Tong, Jie
    Leng, Jianxing
    2018 OCEANS - MTS/IEEE KOBE TECHNO-OCEANS (OTO), 2018,
  • [48] IMPROVED GAS-TIGHT MICRO CROSS-SECTION IONIZATION DETECTOR
    ABEL, K
    ANALYTICAL CHEMISTRY, 1964, 36 (04) : 954 - &
  • [49] A remotely operated serial sampler for collecting gas-tight fluid samples
    Shi-jun Wu
    Can-jun Yang
    Kang Ding
    Chun-yang Tan
    China Ocean Engineering, 2015, 29 : 783 - 792
  • [50] STUDIES OF PHOSPHINE AS A FUMIGANT FOR SACKED RICE UNDER GAS-TIGHT TARPAULINS
    COGBURN, RR
    TILTON, EW
    JOURNAL OF ECONOMIC ENTOMOLOGY, 1963, 56 (05) : 706 - &