Performance testing of gas-tight portable RPC for muography applications

被引:1
|
作者
Kumar, V. [1 ]
Basnet, S. [1 ]
Gil, E. Cortina [1 ]
Demin, P. [1 ]
Gamage, R. M. I. D. [1 ]
Giammanco, A. [1 ]
Karnam, R. [2 ]
Moussawi, M. [1 ]
Samalan, A. [3 ]
Tytgat, M. [3 ,4 ]
Youssef, A. [5 ]
机构
[1] Univ Catholic Louvain, Ctr Cosmol Particle Phys & Phenomenol CP3, Chemin Cyclotron 2, B-1348 Louvain La Neuve, Belgium
[2] Natl Inst Sci Educ & Res NISER, Ctr Med & Radiat Phys CMRP, Khurja 752050, Odisha, India
[3] Univ Ghent, Dept Phys & Astron, Proeftuinstr 86,N3, B-9000 Ghent, Belgium
[4] Vrije Univ Brussel, Phys Dept, Pl Laan 2, B-1050 Brussels, Belgium
[5] Lebanese Univ, Fac Sci, Multidisciplinary Phys Lab, Opt & Fiber Opt Grp, Hadath Campus St 1, Hadath, Lebanon
关键词
Detector design and construction technologies and materials; Gaseous imaging and tracking detectors; Particle tracking detectors (Gaseous detectors); Resistive-plate chambers;
D O I
10.1088/1748-0221/19/04/C04027
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This paper reports the latest developmental efforts for a position -sensitive glass -based Resistive Plate Chamber (RPC) and a multi -channel Data AcQuisition (DAQ) system tailored for muon tracking in muography applications. The designed setup prioritizes portability, aiming for field applications where both the detector and the DAQ operate effectively in external environmental conditions. Comprehensive discussions on hardware development activities and signal processing techniques are included, incorporating noise filtering to enhance the accurate detection of real muons. A muon absorption measurement has also been carried out to understand the behavior of these detectors from an application perspective.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Characterization and stability tests of gas-tight RPC for muography application
    Kumar, Vishal
    Basnet, Samip
    Gil, Eduardo Cortina
    Gamage, R. M. I. D.
    Giammanco, Andrea
    Moussawi, Marwa
    Samalan, Amrutha
    Tytgat, Michael
    Karnam, Raveendrababu
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2025, 1070
  • [2] Towards portable muography with small-area, gas-tight glass Resistive Plate Chambers
    Basnet, S.
    Gil, E. Cortina
    Demin, P.
    Gamage, R. M. I. D.
    Giammanco, A.
    Moussawi, M.
    Tytgat, M.
    Wuyckens, S.
    JOURNAL OF INSTRUMENTATION, 2020, 15 (10):
  • [3] Gas-tight stirrer
    Holm, GE
    Greenbank, GR
    INDUSTRIAL AND ENGINEERING CHEMISTRY, 1924, 16 : 319 - 319
  • [4] A gas-tight stirrer
    Holm, GE
    Greenbank, GR
    INDUSTRIAL AND ENGINEERING CHEMISTRY, 1923, 15 : 1134 - 1134
  • [5] Gas-tight stirrer
    Becker, HG
    INDUSTRIAL AND ENGINEERING CHEMISTRY, 1924, 16 : 319 - 319
  • [6] Gas-tight Biogas Installation
    不详
    BAUINGENIEUR, 2011, 86 : A13 - A13
  • [7] A portable muon telescope based on small and gas-tight resistive plate chambers
    Wuyckens, Sophie
    Giammanco, Andrea
    Gil, Eduardo Cortina
    Demin, Pavel
    PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 2019, 377 (2137):
  • [8] Gas-tight protective suits
    AVR Allgemeiner Vliesstoff-Report, 2001, (03):
  • [9] GAS-TIGHT AND CONVENTIONAL UPRIGHT SILOS
    BROWNING, CB
    JOURNAL OF DAIRY SCIENCE, 1965, 48 (06) : 839 - &
  • [10] GAS-TIGHT METAL FOIL WINDOWS
    ROBINSON, DC
    JOURNAL OF SCIENTIFIC INSTRUMENTS, 1967, 44 (05): : 392 - &