Enhancing the implantation of mechanical circulatory support devices using computational simulations

被引:0
|
作者
Lopez-Santana, Gabriela [1 ,2 ]
De Rosis, Alessandro [1 ]
Grant, Stuart [3 ,4 ]
Venkateswaran, Rajamiyer [2 ,4 ]
Keshmiri, Amir [1 ,3 ]
机构
[1] Univ Manchester, Sch Engn, Manchester, England
[2] Wythenshawe Hosp, Dept Cardiothorac Transplantat & Mech Circulatory, Manchester, England
[3] Manchester Univ NHS Fdn Trust, Manchester Acad Hlth Sci Ctr, Manchester, England
[4] Univ Manchester, Fac Biol, Sch Med Sci, Div Cardiovasc Sci, Manchester, England
基金
英国工程与自然科学研究理事会;
关键词
HeartMate; left ventricular assist device; heart failure; computational fluid dynamics; turbulent flow; aortic flow; outflow graft; surgical optimisation; VENTRICULAR ASSIST DEVICE; WALL SHEAR-STRESS; LVAD OUTFLOW GRAFT; AORTIC-INSUFFICIENCY; BLOOD-FLOW; THROMBOSIS; MODELS; SYSTEM;
D O I
10.3389/fbioe.2024.1279268
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Introduction: Patients with end-stage heart failure (HF) may need mechanical circulatory support such as a left ventricular assist device (LVAD). However, there are a range of complications associated with LVAD including aortic regurgitation (AR) and thrombus formation. This study assesses whether the risk of developing aortic conditions can be minimised by optimising LVAD implantation technique.Methods: In this work, we evaluate the aortic flow patterns produced under different geometrical parameters for the anastomosis of the outflow graft (OG) to the aorta using computational fluid dynamics (CFD). A three-dimensional aortic model is created and the HeartMate III OG positioning is simulated by modifying (i) the distance from the anatomic ventriculo-arterial junction (AVJ) to the OG, (ii) the cardinal position around the aorta, and (iii) the angle between the aorta and the OG. The continuous LVAD flow and the remnant native cardiac cycle are used as inlet boundaries and the three-element Windkessel model is applied at the pressure outlets.Results: The analysis quantifies the impact of OG positioning on different haemodynamic parameters, including velocity, wall shear stress (WSS), pressure, vorticity and turbulent kinetic energy (TKE). We find that WSS on the aortic root (AoR) is around two times lower when the OG is attached to the coronal side of the aorta using an angle of 45 degrees +/- 10 degrees at a distance of 55 mm.Discussion: The results show that the OG placement may significantly influence the haemodynamic patterns, demonstrating the potential application of CFD for optimising OG positioning to minimise the risk of cardiovascular complications after LVAD implantation.
引用
收藏
页数:20
相关论文
共 50 条
  • [21] Hemodynamics with mechanical circulatory support devices using a cardiogenic shock model
    Yahagi, Kazuyuki
    Nishimura, Gohki
    Kuramoto, Kei
    Tsuboko, Yusuke
    Iwasaki, Kiyotaka
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [22] Mechanical circulatory support: devices, outcomes and complications
    Milano, Carmelo A.
    Simeone, Alan A.
    HEART FAILURE REVIEWS, 2013, 18 (01) : 35 - 53
  • [23] Biomechanics and testing of mechanical circulatory support devices
    Borovetz, H
    Antaki, J
    Wagner, W
    Kameneva, M
    Pristas, J
    Winowich, S
    Mandarino, W
    Litwak, P
    Kormos, R
    Griffith, B
    ENGINEERING MECHANICS: PROCEEDINGS OF THE 11TH CONFERENCE, VOLS 1 AND 2, 1996, : 35 - 35
  • [24] Neurocritical Care of Mechanical Circulatory Support Devices
    Aaron Shoskes
    Glenn Whitman
    Sung-Min Cho
    Current Neurology and Neuroscience Reports, 2021, 21
  • [25] Mechanical Circulatory Support Devices and Transcatheter Aortic Valve Implantation (from the National Inpatient Sample)
    Singh, Vikas
    Patel, Samir V.
    Savani, Chirag
    Patel, Nileshkumar J.
    Patel, Nilay
    Arora, Shilpkumar
    Panaich, Sidakpal S.
    Deshmukh, Abhishek
    Cleman, Michael
    Mangi, Abeel
    Forrest, John K.
    Badheka, Apurva O.
    AMERICAN JOURNAL OF CARDIOLOGY, 2015, 116 (10): : 1574 - 1580
  • [26] Gastrointestinal Bleeding During the Index Hospitalization for Mechanical Circulatory Support Devices Implantation, a Nationwide Perspective
    Ali Abbas
    Ahmed Mahmoud
    Mustafa Ahmed
    Juan Aranda
    Charles T. Klodell
    Peter V. Draganov
    Digestive Diseases and Sciences, 2017, 62 : 161 - 174
  • [27] Gastrointestinal Bleeding During the Index Hospitalization for Mechanical Circulatory Support Devices Implantation, a Nationwide Perspective
    Abbas, Ali
    Mahmoud, Ahmed
    Ahmed, Mustafa
    Aranda, Juan, Jr.
    Klodell, Charles T., Jr.
    Draganov, Peter V.
    DIGESTIVE DISEASES AND SCIENCES, 2017, 62 (01) : 161 - 174
  • [28] DISPARITIES IN THE IMPLANTATION OF MECHANICAL CIRCULATORY SUPPORT FOR CARDIOGENIC SHOCK
    Thangam, Manoj
    Luke, Alina
    Amin, Amit P.
    Lasala, John M.
    Maddox, Karen E. Joynt
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 75 (11) : 1325 - 1325
  • [29] Gastrointestinal Bleeding During Index Hospitalization for Mechanical Circulatory Support Devices Implantation: Is the Squeeze Worth the Ooze?
    Darius A. Jahann
    Vanessa M. Shami
    Digestive Diseases and Sciences, 2017, 62 : 7 - 9
  • [30] The Impact of Baseline Renal Dysfunction on Patient Outcomes after Implantation of Chronic Mechanical Circulatory Support Devices
    Anthony, C.
    Lui, R.
    Sevastos, J.
    Dhital, K.
    Granger, E.
    Hayward, C. S.
    Jabbour, A.
    Jansz, P. C.
    Keogh, A. M.
    Kotlyar, E.
    Robson, D.
    Macdonald, P. S.
    Spratt, P. M.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2014, 33 (04): : S200 - S200