Automatic Hand-Eye Calibration Method of Welding Robot Based on Linear Structured Light

被引:3
|
作者
Dongmin, Li [1 ]
Yu, Wang [1 ]
Wenping, Ma [1 ]
Xiujie, Liu [1 ]
Guowei, Ding [1 ]
Guohui, Zhang [1 ]
Jiaqi, Fang [1 ]
机构
[1] Shandong Univ Sci & Technol, Coll Intelligent Equipment, 223 Daizong St, Tai An 271019, Shandong, Peoples R China
关键词
linear structured light; hand-eye calibration; RANSAC; a-shapes algorithm; hand-eye equation AX = ZB;
D O I
10.20965/jrm.2024.p0438
中图分类号
TP24 [机器人技术];
学科分类号
080202 ; 1405 ;
摘要
Aiming at solving the problems such as long calibration time, low precision, and complex operation in hand-eye calibration of welding robot, an automatic hand-eye calibration algorithm based on linear structured light was proposed to solve the calibration matrix X by using AX=ZB calibration equation. Firstly, a square calibration plate is customized to effectively constrain the structured light. The a-shape algorithm was adopted to extract the contour of the 3D point cloud model of the calibration plate. Secondly, an improved random sampling consistency algorithm which could determine the optimal iterative number was proposed to fit the contour point cloud, the contour point cloud model fitted was obtained. Finally, the 3D coordinates of the target points were determined with the linear structured light to complete the hand-eye calibration. In order to prevent the calibration plate from deviating from the acquisition range of the vision sensor during the calibration process, the distance between the linear structural light and the inner circle in the calibration plate was set to limit the motion range of the robot. In order to eliminate the error transfer of the robot body, an optimal solution of the rotation matrix R and the translation vector t of the calibration data was calculated with the singular value decomposition (SVD) and the least square rigid transpose method. The experimental results show that the calibration accuracy reaches 0.3 mm without compensating the robot body error, and the calibration speed is improved by 36% than the existing automatic calibration method. Therefore, the algorithm proposed can automatically complete the calibration only by establishing the user coordinates in advance, which improves the working accuracy and efficiency of the welding robots greatly.
引用
收藏
页码:438 / 448
页数:11
相关论文
共 50 条
  • [31] HAND-EYE CALIBRATION
    HORAUD, R
    DORNAIKA, F
    INTERNATIONAL JOURNAL OF ROBOTICS RESEARCH, 1995, 14 (03): : 195 - 210
  • [32] Simultaneous robot-world and hand-eye calibration
    Dornaika, F
    Horaud, R
    IEEE TRANSACTIONS ON ROBOTICS AND AUTOMATION, 1998, 14 (04): : 617 - 622
  • [33] Simultaneously Calibration of Multi Hand-Eye Robot System Based on Graph
    Zhou, Zishun
    Ma, Liping
    Liu, Xilong
    Cao, Zhiqiang
    Yu, Junzhi
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2023, 71 (05) : 5010 - 5020
  • [34] ON RECURSIVE CALIBRATION OF CAMERAS FOR ROBOT HAND-EYE SYSTEMS
    CHANG, YL
    LIANG, P
    PROCEEDINGS - 1989 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION, VOL 1-3, 1989, : 838 - 843
  • [35] Bayesian Calibration of the Hand-Eye Kinematics of an Anthropomorphic Robot
    Hubert, Uwe
    Stueckler, Joerg
    Behnke, Sven
    2012 12TH IEEE-RAS INTERNATIONAL CONFERENCE ON HUMANOID ROBOTS (HUMANOIDS), 2012, : 618 - 624
  • [36] Automatic Robot Hand-Eye Calibration Enabled by Learning-Based 3D Vision
    Li, Leihui
    Yang, Xingyu
    Wang, Riwei
    Zhang, Xuping
    JOURNAL OF INTELLIGENT & ROBOTIC SYSTEMS, 2024, 110 (03)
  • [37] A Hand-eye Calibration Method of Line Laser Profile Scanning Robot Based on Standard Cylinder
    Gao J.
    Liang D.
    Chen Y.
    Jiqiren/Robot, 2022, 44 (03): : 321 - 332
  • [38] Hand-eye calibration and positioning for a robot drilling system
    Zhan, Qiang
    Wang, Xiang
    INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2012, 61 (5-8): : 691 - 701
  • [39] Hand-eye calibration
    Remy, S
    Dhome, M
    Lavest, JM
    Daucher, N
    IROS '97 - PROCEEDINGS OF THE 1997 IEEE/RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOT AND SYSTEMS: INNOVATIVE ROBOTICS FOR REAL-WORLD APPLICATIONS, VOLS 1-3, 1996, : 1057 - 1065
  • [40] A computationally efficient method for hand-eye calibration
    Zhang, Zhiqiang
    Zhang, Lin
    Yang, Guang-Zhong
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2017, 12 (10) : 1775 - 1787