Automatic Hand-Eye Calibration Method of Welding Robot Based on Linear Structured Light

被引:3
|
作者
Dongmin, Li [1 ]
Yu, Wang [1 ]
Wenping, Ma [1 ]
Xiujie, Liu [1 ]
Guowei, Ding [1 ]
Guohui, Zhang [1 ]
Jiaqi, Fang [1 ]
机构
[1] Shandong Univ Sci & Technol, Coll Intelligent Equipment, 223 Daizong St, Tai An 271019, Shandong, Peoples R China
关键词
linear structured light; hand-eye calibration; RANSAC; a-shapes algorithm; hand-eye equation AX = ZB;
D O I
10.20965/jrm.2024.p0438
中图分类号
TP24 [机器人技术];
学科分类号
080202 ; 1405 ;
摘要
Aiming at solving the problems such as long calibration time, low precision, and complex operation in hand-eye calibration of welding robot, an automatic hand-eye calibration algorithm based on linear structured light was proposed to solve the calibration matrix X by using AX=ZB calibration equation. Firstly, a square calibration plate is customized to effectively constrain the structured light. The a-shape algorithm was adopted to extract the contour of the 3D point cloud model of the calibration plate. Secondly, an improved random sampling consistency algorithm which could determine the optimal iterative number was proposed to fit the contour point cloud, the contour point cloud model fitted was obtained. Finally, the 3D coordinates of the target points were determined with the linear structured light to complete the hand-eye calibration. In order to prevent the calibration plate from deviating from the acquisition range of the vision sensor during the calibration process, the distance between the linear structural light and the inner circle in the calibration plate was set to limit the motion range of the robot. In order to eliminate the error transfer of the robot body, an optimal solution of the rotation matrix R and the translation vector t of the calibration data was calculated with the singular value decomposition (SVD) and the least square rigid transpose method. The experimental results show that the calibration accuracy reaches 0.3 mm without compensating the robot body error, and the calibration speed is improved by 36% than the existing automatic calibration method. Therefore, the algorithm proposed can automatically complete the calibration only by establishing the user coordinates in advance, which improves the working accuracy and efficiency of the welding robots greatly.
引用
收藏
页码:438 / 448
页数:11
相关论文
共 50 条
  • [1] Welding robotic hand-eye calibration method based on structured light plane
    Xu, Fangkai
    Fan, Shengli
    Yang, Qingqing
    Zhang, Chang
    Wang, Yigang
    PROCEEDINGS OF THE 38TH CHINESE CONTROL CONFERENCE (CCC), 2019, : 4571 - 4575
  • [2] Hand-Eye Calibration Method of Line Structured Light Vision Sensor Robot Based on Planar Target
    Wu Qinghua
    Qiu Jiefeng
    Li Zhiang
    Liu Jiacheng
    Wang Biao
    LASER & OPTOELECTRONICS PROGRESS, 2023, 60 (10)
  • [3] A hand-eye calibration method for line structured light system
    Rui, Zhang
    Jun, Wu
    PROCEEDINGS OF THE 30TH CHINESE CONTROL AND DECISION CONFERENCE (2018 CCDC), 2018, : 5758 - 5761
  • [4] Hand-eye calibration in robot welding of aero tube
    Zhang, Zong-Yu
    Gao, Hong-Ming
    Han, Qing-Lin
    Huang, Rui
    Rong, Jian
    Wang, Yong-Chao
    Shanghai Jiaotong Daxue Xuebao/Journal of Shanghai Jiaotong University, 2015, 49 (03): : 392 - 394
  • [5] An algorithm of hand-eye calibration for arc welding robot
    Zeng, Jiang
    Cao, Guangzhong
    Li, Wen-Bo
    Chen, Bao-Chang
    2019 16TH INTERNATIONAL CONFERENCE ON UBIQUITOUS ROBOTS (UR), 2019, : 1 - 6
  • [6] Hand-eye calibration method for a line structured light robot vision system based on a single planar constraint
    Zhong, Kaifan
    Lin, Jingxin
    Gong, Tao
    Zhang, Xianmin
    Wang, Nianfeng
    ROBOTICS AND COMPUTER-INTEGRATED MANUFACTURING, 2025, 91
  • [7] Hand-eye calibration of welding robot based on the constraint of spatial line
    Zheng J.
    Zhang K.
    Luo Z.
    Wang Z.
    Hanjie Xuebao/Transactions of the China Welding Institution, 2018, 39 (08): : 108 - 113
  • [8] Line-feature-based calibration method of structured light plane parameters for robot hand-eye system
    Qi, Yuhan
    Jing, Fengshui
    Tan, Min
    OPTICAL ENGINEERING, 2013, 52 (03)
  • [9] New approach for robot hand-eye calibration based on linear prototype
    Wang, Ying
    Dong, Zai-Li
    Sun, Mao-Xiang
    Xu, Jin-Xue
    Moshi Shibie yu Rengong Zhineng/Pattern Recognition and Artificial Intelligence, 2005, 18 (04): : 491 - 495
  • [10] A vision-based fully-automatic calibration method for hand-eye serial robot
    Wang, Haixia
    Lu, Xiao
    Hu, Zhanyi
    Li, Yuxia
    INDUSTRIAL ROBOT-THE INTERNATIONAL JOURNAL OF ROBOTICS RESEARCH AND APPLICATION, 2015, 42 (01): : 64 - 73