Optimizing the use-by date of reusable medical devices. Experience in a healthcare establishment

被引:0
|
作者
Vidor, Manon [1 ]
Raguenes, Christelle [1 ]
Astier, Helene [1 ]
Gbaguidi, Gilles [1 ]
Le Tohic, Sarah [1 ]
机构
[1] Hop Instruct Armees Laveran, Serv Pharm Hosp, 34 Blvd Laveran, F-13013 Marseille, France
来源
ANNALES PHARMACEUTIQUES FRANCAISES | 2024年 / 82卷 / 02期
关键词
Medical device; Hazard analysis and critical control point; Process evaluation;
D O I
10.1016/j.pharma.2023.12.007
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Objectives. - Sterilized reusable medical devices have a use -by date, after which sterility is no longer guaranteed. There is currently no consensus on how this should be determined. The aim is to re-evaluate the expiry date of reusable medical devices, by means of a risk analysis and an assessment of the maintenance of the sterile state of reusable medical devices over time. Methods. - The risk analysis focused on the stages whose malfunction could compromise the sterility of reusable medical devices over time: packaging, transport and storage. Risk mapping was carried out in accordance with the methodology recommended by the French Health Authority. Based on standard NF EN ISO 11737, the assessment of the maintenance of the sterile state was checked on reusable medical devices after two, four and six months storage and on reusable medical devices that had expired more than a year previously. Results. - The risk analysis identified four failures and sixty-eight potential causes. The most sensitive stage was storage, which accounted for most of the critical and major causes. Improvement actions were proposed, such as the definition of a container maintenance plan. At the same time, 256 reusable medical devices were tested. The cultures remained sterile for all the containers, for folded products tested at 6 months and more and for the sachets tested at 2 and 4 months and at more than one year of storage. Conclusions. - The DLU has been extended to 4 months for sachets, 6 months for folded products and maintained at six months for containers. (c) 2023 Academie Nationale de Pharmacie. Published by Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:292 / 305
页数:14
相关论文
共 29 条
  • [21] Reprocessing of single-use medical devices and their associated problems: an experience from a cancer center in eastern India
    Basu, Debabrata
    Dhara, Mousumi
    Dutta, Sanjay Kishore
    INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2020, 41 (05): : 625 - 627
  • [22] Use of real-time immersive digital training and educational technologies to improve patient safety during the processing of reusable medical devices: Quo Vadis?
    Kremer, T.
    Murray, N.
    Buckley, J.
    Rowan, N. J.
    SCIENCE OF THE TOTAL ENVIRONMENT, 2023, 900
  • [24] Comparison of Results of Local Cryotherapy Obtained with the use of Medical Devices and with the use of Ice in Patients After Reconstruction of the Anterior Cruciate Ligament in the Context of Guaranteed Healthcare Services
    Bednarski, Piotr
    Kiwerski, Jerzy E.
    ACTA BALNEOLOGICA, 2020, 62 (01): : 47 - 54
  • [25] A Clean You Can Trust: Using an Evidence-Based Bundle to Transform Point-of-Use Treatment for Reusable Medical Devices at a Military Treatment Facility
    Atwood, Bethany, I
    Eberhardt, Gina L.
    Smith, Joshua D.
    Lawton, Danielle N.
    MacDonald, Erin M.
    Romito, Kenneth
    MILITARY MEDICINE, 2024,
  • [26] Use of Gloves and Reduction of Risk of Injury Caused by Needles or Sharp Medical Devices in Healthcare Workers: Results from a Case-Crossover Study
    Kinlin, Laura M.
    Mittleman, Murray A.
    Harris, Anthony D.
    Rubin, Michael A.
    Fisman, David N.
    INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2010, 31 (09): : 908 - 917
  • [27] Healthcare Experts' Advisory Unit and Support (HAUS) Program for Medical Device Development in Korea: Introduction of Clinical Unmet Needs-Based Intended Use Establishment (CLUE) Templates
    Lee, You Kyoung
    Lih, Eugene
    Kim, Minyoung
    Kim, Soo Young
    Nam, Ki Chang
    Choi, Jaesoon
    Park, Il-Ho
    Lee, Su-Kyoung
    Tun, Soe Ye Yint
    Phoo, Ei Shwe Yi
    Lee, Jin Woo
    JOURNAL OF KOREAN MEDICAL SCIENCE, 2024, 39 (40)
  • [29] A standardized description of graft-containing meshes and recommended steps before the introduction of medical devices for prolapse surgery: Consensus of the 2nd IUGA grafts roundtable: Optimizing safety and appropriateness of graft use in transvaginal pelvic reconstructive surgery
    Slack M.
    Ostergard D.
    Cervigni M.
    Deprest J.
    International Urogynecology Journal, 2012, 23 (Suppl 1) : S15 - S26