Cardiac Magnetic Resonance and Cardiac Implantable Electronic Devices: Are They Truly Still "Enemies"?

被引:0
|
作者
Fogante, Marco [1 ]
Volpato, Giovanni [2 ]
Pirani, Paolo Esposto [1 ]
Cela, Fatjon [1 ]
Compagnucci, Paolo [2 ]
Valeri, Yari [2 ]
Selimi, Adelina [2 ]
Alfieri, Michele [2 ]
Brugiatelli, Leonardo [2 ]
Belleggia, Sara [2 ]
Coraducci, Francesca [2 ]
Argalia, Giulio [1 ]
Casella, Michela [2 ,3 ]
Dello Russo, Antonio [2 ,4 ]
Schicchi, Nicolo [5 ]
机构
[1] Univ Hosp Marche, Dept Radiol Sci, Maternal Child Senol Cardiol Radiol & Outpatient U, I-60126 Ancona, Italy
[2] Univ Hosp Azienda Osped Univ Marche, Cardiol & Arrhythmol Clin, I-60126 Ancona, Italy
[3] Marche Polytech Univ, Dept Clin Special & Dent Sci, I-60121 Ancona, Italy
[4] Marche Polytech Univ, Dept Biomed Sci & Publ Hlth, I-60121 Ancona, Italy
[5] Univ Hosp Marche, Dept Radiol Sci, Cardiovasc Radiol Diagnost, Ancona, Italy
来源
MEDICINA-LITHUANIA | 2024年 / 60卷 / 04期
关键词
cardiac magnetic resonance; cardiac implantable electronic device; pacemaker; implantable cardiac defibrillator; loop recorder; safety; artifacts; CARDIOVERTER-DEFIBRILLATORS; SAFETY; RISK; MRI; CT; ELECTROPHYSIOLOGY; PACEMAKERS; SOCIETY; SYNCOPE; PATIENT;
D O I
10.3390/medicina60040522
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The application of cardiac magnetic resonance (CMR) imaging in clinical practice has grown due to technological advancements and expanded clinical indications, highlighting its superior capabilities when compared to echocardiography for the assessment of myocardial tissue. Similarly, the utilization of implantable cardiac electronic devices (CIEDs) has significantly increased in cardiac arrhythmia management, and the requirements of CMR examinations in patients with CIEDs has become more common. However, this type of exam often presents challenges due to safety concerns and image artifacts. Until a few years ago, the presence of CIED was considered an absolute contraindication to CMR. To address these challenges, various technical improvements in CIED technology, like the reduction of the ferromagnetic components, and in CMR examinations, such as the introduction of new sequences, have been developed. Moreover, a rigorous protocol involving multidisciplinary collaboration is recommended for safe CMR examinations in patients with CIEDs, emphasizing risk assessment, careful monitoring during CMR, and post-scan device evaluation. Alternative methods to CMR, such as computed tomography coronary angiography with tissue characterization techniques like dual-energy and photon-counting, offer alternative potential solutions, although their diagnostic accuracy and availability do limit their use. Despite technological advancements, close collaboration and specialized staff training remain crucial for obtaining safe diagnostic CMR images in patients with CIEDs, thus justifying the presence of specialized centers that are equipped to handle these type of exams.
引用
收藏
页数:18
相关论文
共 50 条
  • [41] Cardiac implantable electronic devices and cybersecurity
    Patel, Bhakti
    Makaryus, Amgad N.
    EXPERT REVIEW OF MEDICAL DEVICES, 2021, 18 (18) : 69 - 77
  • [42] Innovations in Cardiac Implantable Electronic Devices
    Khurrum Khan
    Jitae A. Kim
    Andra Gurgu
    Muzamil Khawaja
    Dragos Cozma
    Mihail G. Chelu
    Cardiovascular Drugs and Therapy, 2022, 36 : 763 - 775
  • [43] Cybersecurity in cardiac implantable electronic devices
    Martignani, Cristian
    EXPERT REVIEW OF MEDICAL DEVICES, 2019, 16 (06) : 437 - 444
  • [44] MRI and implantable cardiac electronic devices
    Jung, Werner
    Jaeckle, Sebastian
    Zvereva, Vlada
    CURRENT OPINION IN CARDIOLOGY, 2015, 30 (01) : 65 - 73
  • [45] Extraction of implantable cardiac electronic devices
    Rickard J.
    Wilkoff B.L.
    Current Cardiology Reports, 2011, 13 (5) : 407 - 414
  • [46] Treatment with cardiac electronic implantable devices
    Kuschyk, Juergen
    Sattler, Katherine
    Fastenrath, Fabian
    Rudic, Boris
    Akin, Ibrahim
    HERZ, 2024, 49 (03) : 233 - 246
  • [47] Reducing cardiac implantable electronic device–induced artefacts in cardiac magnetic resonance imaging
    Aino-Maija Vuorinen
    Lauri Lehmonen
    Jarkko Karvonen
    Miia Holmström
    Sari Kivistö
    Touko Kaasalainen
    European Radiology, 2023, 33 : 1229 - 1242
  • [48] Cardiovascular Magnetic Resonance in Patients With Magnetic Resonance-Conditional Cardiac Implantable Electronic Devices What Can We See?
    Simonetti, Orlando P.
    Gross, David C.
    CIRCULATION-CARDIOVASCULAR IMAGING, 2016, 9 (05)
  • [49] Sudden cardiac arrest in patients with cardiac implantable electronic devices
    Sharifzadehgan, A.
    Bougouin, W.
    Narayanan, K.
    Dumas, F.
    Waldmann, V.
    Gandjbakhch, E.
    Aissaoui, N.
    Algalarrondo, V.
    Extramiana, F.
    Lellouche, N.
    Cariou, A.
    Jouven, X.
    Marijon, E.
    EUROPEAN HEART JOURNAL, 2018, 39 : 213 - 213
  • [50] Forces on cardiac implantable electronic devices during remote magnetic navigation
    Jilek, C.
    Lennerz, C.
    Stracke, B.
    Badran, H.
    Semmler, V.
    Reents, T.
    Ammar, S.
    Hessling, G.
    Deisenhofer, I.
    Kolb, C.
    EUROPEAN HEART JOURNAL, 2012, 33 : 983 - 983