Establishment of local diagnostic reference levels for radiation dose in paediatric interventional cardiology procedures in Brazil

被引:0
|
作者
Yagui, Akemi [1 ]
Schelin, Hugo [1 ]
Mello, Rosiane [1 ]
Andrade, Diancarlos [1 ]
Vosiak, Paula [1 ]
Denyak, Valeriy [2 ,3 ]
Filipov, Danielle [3 ]
Paschuk, Sergei [3 ]
Khoury, Helen [4 ]
Ubeda, Carlos [5 ]
机构
[1] Pele Pequeno Principe Res Inst, Pequeno Principe Fac, Curitiba, PR, Brazil
[2] Natl Sci Ctr Kharkov Inst Phys & Technol, Kharkiv, Ukraine
[3] Fed Univ Technol, Curitiba, Parana, Brazil
[4] Univ Fed Pernambuco, Recife, Brazil
[5] Tarapaca Univ, Hlth Sci Fac, Med Technol Dept, Arica, Chile
关键词
Interventional cardiology; Paediatric; Radiation dose; Diagnostic reference levels; CARDIAC-CATHETERIZATION; EXPOSURE;
D O I
10.1016/j.radphyschem.2024.111577
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Diagnostic and therapeutic interventional cardiology procedures are essential tools for evaluating congenital pathologies in paediatric patients. However, these procedures may expose patients to high levels of ionizing radiation. In this paper, we present the results of the radiation doses received by patients undergoing interventional cardiac procedures at a paediatric hospital in Brazil, aiming to establish local Diagnostic Reference Levels (DRL). The data were collected over a period of three years (2019-2022), and 148 procedures were analyzed, comprising 53% male (78) and 47% female (70) patients. These procedures included both diagnostic (59%) and therapeutic (41%) cardiac catheterization interventions. The average patient weight was 21.4 +/- 1.7 kg (2.0-112.0 kg), with an average age of 5.3 +/- 0.4 years (0.0-17.1 years). Comprehensive data for each procedure were extracted from Radiation Dose Structure Reports generated by the equipment. The results showed significant differences between diagnostic and therapeutic procedures, and the DRL values were estimated considering the age and weight of the patients. The DRL values correspond to the 3rd quartile of the dose distribution for each group. The following local DRL values were estimated, considering the patient's ages. For diagnostic procedures, the P-KA defined according to the age groups <1, 1-5, 5-10, 10-15, and >15 years were respectively: 1.4, 2.8, 3.1, 4.3 and 12.0 Gy cm(2). For therapeutic procedures, the DRL values for patients with the same ages were: 2.0, 3.7, 5.4, 7.4, and 30.9 Gy cm(2). For the total procedures, the P-KA values were 1.7, 3.2, 4.9, 6.6, and 24.5 Gy cm(2), respectively. The suggested local DRL values for weight groups (<5, 5-15, 15-30, 30-50, and 50-80 kg) for P-KA in diagnostic procedures were: 1.3, 2.2, 3.2, 4.1, and 7.9 Gy cm(2), respectively. For therapeutic procedures, the P-KA values were 1.1, 2.7, 5.4, 5.5, and 30.9 Gy cm(2), respectively. For the total procedures, the P-KA values were 1.25, 2.5, 4.6, 4.2, and 18.3 Gy cm(2), respectively. For establishing P-KA DRL, patient weight was found to be preferable over age, whereas for K-a,K-r, both approaches yielded nearly identical results.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Monitoring neurointerventional radiation doses using dose-tracking software: implications for the establishment of local diagnostic reference levels
    Holly Acton
    Karl James
    Richard G. Kavanagh
    Colm O’Tuathaigh
    Deirdre Moloney
    Gerald Wyse
    Noel Fanning
    Michael Maher
    Owen J. O’Connor
    European Radiology, 2018, 28 : 3669 - 3675
  • [42] Preliminary reference levels in interventional cardiology
    V. Neofotistou
    E. Vano
    R. Padovani
    J. Kotre
    A. Dowling
    M. Toivonen
    S. Kottou
    V. Tsapaki
    S. Willis
    G. Bernardi
    K. Faulkner
    European Radiology, 2003, 13 : 2259 - 2263
  • [43] Preliminary reference levels in interventional cardiology
    Neofotistou, V
    Vano, E
    Padovani, R
    Kotre, J
    Dowling, A
    Toivonen, M
    Kottou, S
    Tsapaki, V
    Willis, S
    Bernardi, G
    Faulkner, K
    EUROPEAN RADIOLOGY, 2003, 13 (10) : 2259 - 2263
  • [44] Establishment and utilization of diagnostic reference level for interventional procedures for adult patients in Ghana
    Issahaku, Shiraz
    Hasford, Francis
    Azantillow, Norbert
    Sackey, Theophilus Akumea
    Nunoo, George
    Dzefi-Tettey, Klenam
    Mensah, Yaw Boateng
    Amponsah, Becky Appiah
    Tagoe, Samuel
    Esposito, Marco
    Padovani, Renato
    HEALTH AND TECHNOLOGY, 2024, 14 (06) : 1135 - 1147
  • [45] Occupational eye dose in interventional cardiology procedures
    Haga, Yoshihiro
    Chida, Koichi
    Kaga, Yuji
    Sota, Masahiro
    Meguro, Taiichiro
    Zuguchi, Masayuki
    SCIENTIFIC REPORTS, 2017, 7
  • [46] Occupational eye dose in interventional cardiology procedures
    Yoshihiro Haga
    Koichi Chida
    Yuji Kaga
    Masahiro Sota
    Taiichiro Meguro
    Masayuki Zuguchi
    Scientific Reports, 7
  • [47] ESTABLISHING LOCAL AND NATIONAL DIAGNOSTIC AND INTERVENTIONAL CARDIOLOGY AND RADIOLOGY REFERENCE LEVELS IN A SMALL EUROPEAN STATE: THE CASE OF MALTA
    Pace, Eric
    Cortis, Kelvin
    Debono, Joseph
    Grech, Marvin
    Caruana, Carmel J.
    RADIATION PROTECTION DOSIMETRY, 2020, 191 (03) : 261 - 271
  • [48] Proposed local diagnostic reference levels in angiography and interventional neuroradiology and a preliminary analysis according to the complexity of the procedures
    D'Ercole, Loredana
    Thyrion, Federico Zappoli
    Bocchiola, Milena
    Mantovani, Laura
    Klersy, Catherine
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2012, 28 (01): : 61 - 70
  • [49] A Contribution to the Establishment of Diagnostic Reference Levels in Computed Tomography in Brazil
    Narciso, L. D. L.
    Lima, N. W.
    Dartora, C. M.
    Marques da Silva, A. M.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, 2015, VOLS 1 AND 2, 2015, 51 : 737 - 740
  • [50] Establishment of local diagnostic reference levels in paediatric screen-film radiography at a children's hospital
    Wambani, J. S.
    Korir, G. K.
    Korir, I. K.
    Kilaha, S.
    RADIATION PROTECTION DOSIMETRY, 2013, 154 (04) : 465 - 476