Timber-framed exterior walls insulated with wood shavings: A field study in a nordic climate

被引:3
|
作者
Hietikko, Jaakko [1 ]
Tuominen, Eero [1 ]
Valovirta, Ilkka [1 ]
Vinha, Juha [1 ]
机构
[1] Tampere Univ, Fac Built Environm, POB 600,Bldg Phys, FI-33014 Tampere, Finland
关键词
Building envelope; Timber-frame exterior wall; Mould index; Thermal insulation; Wood shavings; THERMAL-CONDUCTIVITY; PROCESSING RESIDUES; BUILDING USE; HYGROTHERMAL PERFORMANCE; MOISTURE CONDITIONS; DENSITY; PANEL; RESISTANCE; FIBER; MODEL;
D O I
10.1016/j.buildenv.2024.111371
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Wood processing residues provide a possibility to produce thermal insulation material with low environmental impact. This paper deals with the hygrothermal performance of timber-framed exterior walls with wood shavings as insulation material. The presented study consisted of field measurements of five exterior wall structures with two different types of wood shavings insulation and three reference walls. The study was performed in cold Nordic climate, where hygrothermal conditions at outer parts of a wall structure are critical. Untreated wood shavings and wood shavings coated with pulverized clay were compared as insulation materials. Different wind barriers as well as a water vapour barrier and sheathing acting as vapour retarder were also used. Results indicated no suitable conditions for mould growth inside any wall. The thermal resistance of wind barriers as well as the clay-coating of wood shavings had positive effect on the hygrothermal performance of the test walls. Wood shavings proved to be suitable insulation materials for well-insulated structures from the hygrothermal point of view, when the overall design, construction and maintenance are carried out in a proper way.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Experimental Evaluation and Numerical Modelling of Timber-Framed Walls
    Ferreira, J. G.
    Teixeira, M. J.
    Dutu, A.
    Branco, F. A.
    Goncalves, A. M.
    EXPERIMENTAL TECHNIQUES, 2014, 38 (04) : 45 - 53
  • [2] Fire Analysis of Timber-Framed Walls Lined with Gypsum
    Piloto, Paulo A. G.
    Rodriguez-del-Rio, Sergio
    Vergara, Diego
    MATERIALS, 2022, 15 (03)
  • [3] Experimental evaluation and numerical modelling of timber-framed walls
    J. G. Ferreira
    M. J. Teixeira
    A. Duţu
    F. A. Branco
    A. M. Gonçalves
    Experimental Techniques, 2014, 38 : 45 - 53
  • [4] Hygrothermal Performance of Wood Shavings as Thermal Insulation of Exterior Walls in Cold Climate
    Huttunen, Petteri
    Vinha, Juha
    MULTIPHYSICS AND MULTISCALE BUILDING PHYSICS, IBPC 2024, VOL 3, 2025, 554 : 290 - 301
  • [5] CASE STUDY OF TEMPERATURES AND ENERGY CONSUMPTION IN A HIGHLY INSULATED TIMBER-FRAMED HOUSE.
    Anderson, B.R.
    Heating and Ventilating Engineer: The Journal of Environmental Services, 1980, 54 (630): : 6 - 12
  • [6] Mathematical modelling of timber-framed walls strengthened with CFRP strips
    Premrov, Miroslav
    Dobrila, Peter
    APPLIED MATHEMATICAL MODELLING, 2008, 32 (05) : 725 - 737
  • [7] Simplified modelling of timber-framed walls under lateral loads
    Vogrinec, Katja
    Premrov, Miroslav
    Silih, Erika Kozem
    ENGINEERING STRUCTURES, 2016, 111 : 275 - 284
  • [8] Slip modeling in timber-framed walls with wood-based or fibre-plaster sheathing boards
    Premrov, M.
    Dobrila, P.
    Bedenik, B. S.
    Spacapan, I.
    PROCEEDINGS OF THE 9TH WSEAS INTERNATIONAL CONFERENCE ON MATHEMATICAL AND COMPUTATIONAL METHODS IN SCIENCE AND ENGINEERING (MACMESE '07)/ DNCOCO '07, 2007, : 229 - 235
  • [9] Hygrothermal Behaviour of the Timber-Framed Sauna with Straw-Bale Walls
    Miljan, Martti-Jaan
    Allikmae, Rain
    Jurgenson, Andres
    Miljan, Matis
    Miljan, Jaan
    6TH INTERNATIONAL SCIENTIFIC CONFERENCE RESEARCH FOR ENVIRONMENT AND CIVIL ENGINEERING DEVELOPMENT (CIVIL ENGINEERING 17), VOL 6, 2017, 6 : 124 - 130
  • [10] Mathematical modelling of timber-framed walls using fictive diagonal elements
    Pintaric, Katja
    Premrov, Miroslav
    APPLIED MATHEMATICAL MODELLING, 2013, 37 (16-17) : 8051 - 8059