Hygrothermal Behaviour of the Timber-Framed Sauna with Straw-Bale Walls

被引:0
|
作者
Miljan, Martti-Jaan [1 ]
Allikmae, Rain [1 ]
Jurgenson, Andres [1 ]
Miljan, Matis [1 ]
Miljan, Jaan [1 ]
机构
[1] Estonian Univ Life Sci, Tartu, Estonia
关键词
construction process of straw-bale walls; thermal conductivity of straw-bale walls; relative moisture content; lime plaster; clay plaster;
D O I
10.22616/CE.2017.017
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In the autumn of 2016 a timber-framed sauna with straw-bale walls was built for testing hygrothermal properties of walls during permanent usage. The main dimensions of the building's plan were 6.58 x 4.08 m with two rooms on the ground floor: a resting room and a room for washing and wetting (sauna part). The thickness of walls depended on the straw-bale dimensions which were 50 cm. External surfaces of the walls were plastered with the lime plaster. Both clay and lime plasters were used inside to check a better plaster variant for straw. Measuring devices and sensors to determine the temperature and relative moisture content were mounted into walls during construction. The heat flux rate through the wall was measured with a heat flux plate; data were recorded by an Almemo data recorder. Measurements began in December 2016 and ended in April 2017. The heating procedure of the sauna took place once a week. Meanwhile the sauna was heated with electric batteries. The measuring results were interesting. During the heating time the temperature inside the steam room rose to 83 degrees C, but in the middle of the wall it was 23 degrees C. At the same time the external temperature was about 0 degrees C. The data based calculation of thermal transmittance of the wall was U = 0.15 W/m(2)K which was a little lower than predicted.
引用
收藏
页码:124 / 130
页数:7
相关论文
共 50 条
  • [1] Thermal bridge occurrence in straw-bale timber frame walls
    Brzyski, P.
    Kosinski, P.
    Nadratowska, M.
    IV INTERNATIONAL CONFERENCE OF COMPUTATIONAL METHODS IN ENGINEERING SCIENCE (CMES'19), 2019, 710
  • [2] Allowable Shears for Plastered Straw-Bale Walls
    Aschheim, M.
    Jalali, S.
    Ash, C.
    Donahue, K.
    Hammer, M.
    JOURNAL OF STRUCTURAL ENGINEERING, 2015, 141 (02)
  • [3] Hygrothermal performance of timber-framed walls in Turkey - Long-term monitoring
    Kilicaslan, Aysegul Eksi
    Kus, Hulyas
    JOURNAL OF BUILDING ENGINEERING, 2024, 94
  • [4] Shear behaviour of reinforced straw-bale plaster sheathed cold-formed steel-framed shear walls
    Sun, Huaishuan
    Cao, Baozhu
    Chen, Zhihua
    Du, Yansheng
    BIOSYSTEMS ENGINEERING, 2022, 221 : 54 - 68
  • [5] An investigation of the moisture content in the walls of a straw-bale building
    Goodhew, S
    Griffiths, R
    Woolley, T
    BUILDING AND ENVIRONMENT, 2004, 39 (12) : 1443 - 1451
  • [6] Hygrothermal calculations and laboratory tests on timber-framed wall structures
    Kalamees, T
    Vinha, J
    BUILDING AND ENVIRONMENT, 2003, 38 (05) : 689 - 697
  • [7] Experimental Evaluation and Numerical Modelling of Timber-Framed Walls
    Ferreira, J. G.
    Teixeira, M. J.
    Dutu, A.
    Branco, F. A.
    Goncalves, A. M.
    EXPERIMENTAL TECHNIQUES, 2014, 38 (04) : 45 - 53
  • [8] Fire Analysis of Timber-Framed Walls Lined with Gypsum
    Piloto, Paulo A. G.
    Rodriguez-del-Rio, Sergio
    Vergara, Diego
    MATERIALS, 2022, 15 (03)
  • [9] Experimental evaluation and numerical modelling of timber-framed walls
    J. G. Ferreira
    M. J. Teixeira
    A. Duţu
    F. A. Branco
    A. M. Gonçalves
    Experimental Techniques, 2014, 38 : 45 - 53
  • [10] Mathematical modelling of timber-framed walls strengthened with CFRP strips
    Premrov, Miroslav
    Dobrila, Peter
    APPLIED MATHEMATICAL MODELLING, 2008, 32 (05) : 725 - 737