Performance testing of a long-strip two-end readout multi-gap resistive plate chamber

被引:0
|
作者
王小斌
王义
罗明
李元景
程建平
机构
[1] DepartmentofEngineeringPhysics,TsinghuaUniversity
关键词
D O I
暂无
中图分类号
O572.212 [];
学科分类号
摘要
Multi-gap Resistive Plate Chamber (MRPC) is a new generation of gas detector with good tim-ing and spacial resolution, whose technique is widely applied in some recent high energy (nuclear) physics experiments. In this letter, we report a long-strip two-end readout MRPC and its test beam performance. The measurements show that the long-strip performs a transmission line characteristic and the impedance is independent of the length of strip. The MRPC module we developed is presented to gain a timing resolution of ~80 ps and a spacial resolution of ~6.4 mm. The possible application of the MRPC is also discussed.
引用
收藏
页码:114 / 118
页数:5