Performance testing of a long-strip two-end readout multi-gap resistive plate chamber

被引:0
|
作者
王小斌
王义
罗明
李元景
程建平
机构
[1] DepartmentofEngineeringPhysics,TsinghuaUniversity
关键词
D O I
暂无
中图分类号
O572.212 [];
学科分类号
摘要
Multi-gap Resistive Plate Chamber (MRPC) is a new generation of gas detector with good tim-ing and spacial resolution, whose technique is widely applied in some recent high energy (nuclear) physics experiments. In this letter, we report a long-strip two-end readout MRPC and its test beam performance. The measurements show that the long-strip performs a transmission line characteristic and the impedance is independent of the length of strip. The MRPC module we developed is presented to gain a timing resolution of ~80 ps and a spacial resolution of ~6.4 mm. The possible application of the MRPC is also discussed.
引用
收藏
页码:114 / 118
页数:5
相关论文
共 42 条
  • [1] Performance testing of a long-strip two-end readout multi-gap resistive plate chamber
    Wang Xiao-Bin
    Wang Yi
    Luo Ming
    CHINESE PHYSICS C, 2009, 33 (02) : 114 - 118
  • [2] Performance testing of a long-strip two-end readout multi-gap resistive plate chamber
    王小斌
    王义
    罗明
    李元景
    程建平
    Chinese Physics C, 2009, (02) : 114 - 118
  • [3] Performance of two different modules of long-strip multi-gap resistive plate chamber
    CHEN Huangshan WANG Yi~* DING Weicheng QIU Xuezhong WANG Jingbo ZHU Xianglei CHENG Jianping LI Yuanjing Department of Engineering Physics
    Nuclear Science and Techniques, 2011, 22 (06) : 330 - 333
  • [4] Performance of two different modules of long-strip multi-gap resistive plate chamber
    Chen Huangshan
    Wang Yi
    Ding Weicheng
    Qiu Xuezhong
    Wang Jingbo
    Zhu Xianglei
    Cheng Jianping
    Li Yuanjing
    NUCLEAR SCIENCE AND TECHNIQUES, 2011, 22 (06) : 330 - 333
  • [5] Production of long-strip multi-gap resistive plate chamber module for the STAR-MTD system
    Chen, H.
    Wang, Y.
    Gonzalez-Diaz, D.
    Wang, J.
    Fan, X.
    Cheng, J.
    Li, Y.
    JOURNAL OF INSTRUMENTATION, 2012, 7
  • [6] Design and test of a Multi-gap Resistive Plate Chamber with Long readout-strip (LMRPC)
    孙勇杰
    李澄
    周意
    邵明
    赵艳娥
    陈宏芳
    中国物理C, 2009, 33 (02) : 119 - 122
  • [7] Design and test of a Multi-gap Resistive Plate Chamber with Long readout-strip (LMRPC)
    孙勇杰
    李澄
    周意
    邵明
    赵艳娥
    陈宏芳
    Chinese Physics C, 2009, (02) : 119 - 122
  • [8] Design and test of a Multi-gap Resistive Plate Chamber with Long readout-strip (LMRPC)
    Sun Yong-Jie
    Li Cheng
    Zhou Yi
    Shao Ming
    Zhao Yan-E
    Chen Hong-Fang
    CHINESE PHYSICS C, 2009, 33 (02) : 119 - 122
  • [9] Response of multi-strip multi-gap resistive plate chamber
    Datta, Ushasi
    Chakraborty, S.
    Rahaman, A.
    Basu, P.
    Basu, J.
    Bemmerer, D.
    Boretzky, K.
    Elekes, Z.
    Kempe, M.
    Munzenberg, G.
    Simon, H.
    Sobiella, M.
    Stach, D.
    Wagnerb, A.
    Yakorev, D.
    JOURNAL OF INSTRUMENTATION, 2015, 10
  • [10] Performance test of preamplifiers for Multi-gap Resistive plate chamber (MRPC)
    Lim, HS
    Yoon, JY
    Min, SH
    Kim, EG
    Choi, DB
    Park, JH
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 812 - 815