A CURRENT INJECTING DEVICE FOR ELECTRICAL-IMPEDANCE TOMOGRAPHY

被引:3
|
作者
BLAD, B [1 ]
LINDSTROM, K [1 ]
BERTENSTAM, L [1 ]
PERSSON, BRR [1 ]
HOLMER, NG [1 ]
机构
[1] LUND INST TECHNOL, DEPT ELECT MEASUREMENTS, S-22007 LUND, SWEDEN
关键词
D O I
10.1088/0967-3334/15/2A/010
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Electrical impedance tomography (EIT) has to be improved in order to become an accepted diagnostic technique in clinical use. The aim of this study is to improve the hardware of this technique and preferably upgrade the current injecting device. Instead of using a constant current generator the idea is to implement a voltage source and measure current accurately, in order to improve the resolution in the image. The performance of such a device is analysed, particularly concerning theoretical and practical limitations. The amplitude and phase accuracy, noise and settling time are measured and presented in diagrams, The results show that improvements are possible to achieve and that such a device will improve the stability of an EIT system and the image quality.
引用
收藏
页码:A69 / A77
页数:9
相关论文
共 50 条
  • [41] NEURAL NETWORKS FOR ELECTRICAL-IMPEDANCE TOMOGRAPHY IMAGE CHARACTERIZATION
    MILLER, AS
    BLOTT, BH
    HAMES, TK
    CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1992, 13 : 119 - 123
  • [42] ELECTRICAL-IMPEDANCE TOMOGRAPHY SYSTEMS BASED ON VOLTAGE DRIVE
    SANSEN, W
    GEERAERTS, B
    VANPETEGEM, W
    STEYAERT, M
    CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1992, 13 : 39 - 42
  • [43] FINITE-ELEMENT METHOD IN ELECTRICAL-IMPEDANCE TOMOGRAPHY
    WOO, EJ
    HUA, P
    WEBSTER, JG
    TOMPKINS, WJ
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1994, 32 (05) : 530 - 536
  • [44] ELECTRICAL-IMPEDANCE TOMOGRAPHY USING INDUCED AND INJECTED CURRENTS
    GENCER, NG
    IDER, YZ
    KUZUOGLU, M
    CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1992, 13 : 95 - 99
  • [45] MEASURING LUNG RESISTIVITY USING ELECTRICAL-IMPEDANCE TOMOGRAPHY
    WOO, EJ
    HUA, P
    WEBSTER, JG
    TOMPKINS, WJ
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1992, 39 (07) : 756 - 760
  • [46] PERFORMANCE OF A DIFFERENTIAL SYNCHRONOUS DEMODULATOR FOR ELECTRICAL-IMPEDANCE TOMOGRAPHY
    KOUKOURLIS, CS
    TRIGONIDIS, VK
    KYRIAKOU, GA
    SAHALOS, JN
    BATAS, K
    CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1992, 13 : 35 - 38
  • [47] RAW DATA INTERCHANGE FORMAT FOR ELECTRICAL-IMPEDANCE TOMOGRAPHY
    RECORD, PM
    COSTA, PJR
    CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1992, 13 : 201 - 207
  • [48] COMMENT ON THE ALTERNATIVE RECONSTRUCTION ALGORITHM FOR ELECTRICAL-IMPEDANCE TOMOGRAPHY
    KOTRE, CJ
    CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1989, 10 (04): : 370 - 371
  • [49] AN IMAGE-ENHANCEMENT TECHNIQUE FOR ELECTRICAL-IMPEDANCE TOMOGRAPHY
    DOBSON, DC
    SANTOSA, F
    INVERSE PROBLEMS, 1994, 10 (02) : 317 - 334
  • [50] IDENTIFYING ESOPHAGEAL CONTENTS USING ELECTRICAL-IMPEDANCE TOMOGRAPHY
    EROL, RA
    MANGNALL, Y
    LEATHARD, AD
    SMALLWOOD, RH
    BROWN, BH
    CHERIAN, P
    BARDHAN, KD
    PHYSIOLOGICAL MEASUREMENT, 1995, 16 (04) : 253 - 261