VOLTAMMETRIC TRACE DETERMINATION OF UBIQUINONES AT MERCURY-ELECTRODES

被引:10
|
作者
EMONS, H [1 ]
WITTSTOCK, G [1 ]
VOIGT, B [1 ]
SEIDEL, H [1 ]
机构
[1] INST BIOTECHNOL,O-7010 LEIPZIG,GERMANY
来源
关键词
D O I
10.1007/BF00321867
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Voltammetric methods were developed for the determination of ubiquinones on the basis of their adsorption and redox behaviour at mercury electrodes. Linear calibration plots were obtained in the concentration range between 10(-4) mol/l and 2.3.10(-5) mol/l from differential pulse voltammetric measurements under experimental conditions avoiding significant adsorption of the analyte. A remarkable decrease of the detection limit down to 10(-7) mol/l was achieved with the help of adsorptive accumulation of ubiquinone molecules at the mercury electrode followed by differential pulse detection. The resulting non-linear calibration plot was explained with a model, which takes into account both adsorption and diffusion of the analyte.
引用
收藏
页码:737 / 739
页数:3
相关论文
共 50 条
  • [41] INVESTIGATION OF THE MERCURY(II) COMPLEX WITH TRIETHYLENETETRAMINE BY MEANS OF GLASS AND MERCURY-ELECTRODES
    DUNNIGAN, PC
    WATTERS, JI
    ANALYTICA CHIMICA ACTA, 1983, 154 (NOV) : 329 - 334
  • [42] ELECTROCHEMICAL OXIDATION OF NIAZID AND ISONIAZID AT MERCURY-ELECTRODES - INFLUENCE OF THE ADSORPTION OF THE REACTION-PRODUCT ON THE POLAROGRAPHIC AND VOLTAMMETRIC CURVES
    MELLADO, JMR
    ANGULO, M
    GALVIN, RM
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1993, 352 (1-2) : 253 - 265
  • [43] VOLTAMMETRY OF HALIDE-IONS ON MERCURY-ELECTRODES IN ACETONITRILE
    WOJCIECHOWSKI, M
    OSTERYOUNG, J
    ANALYTICAL CHEMISTRY, 1984, 56 (11) : 1884 - 1890
  • [44] Polarographic and voltammetric determination of genotoxic 4-nitroindane at mercury electrodes
    Vendula Němcová
    Vlastimil Vyskočil
    Jiří Barek
    Monatshefte für Chemie - Chemical Monthly, 2016, 147 : 143 - 151
  • [45] Polarographic and voltammetric determination of genotoxic 4-nitroindane at mercury electrodes
    Nemcova, Vendula
    Vyskocil, Vlastimil
    Barek, Jiri
    MONATSHEFTE FUR CHEMIE, 2016, 147 (01): : 143 - 151
  • [46] Screen printed electrodes for improvised voltammetric determination of mercury(II) ions
    Kaur K.
    Mittal S.K.
    Ashok Kumar S.K.
    Kumar A.
    Kumar S.
    Metters J.P.
    Banks C.E.
    Mittal, Susheel K. (smittal@thapar.edu), 1600, American Scientific Publishers (14): : 515 - 521
  • [47] Voltammetric determination of metal ions beyond mercury electrodes. A review
    Arino, Cristina
    Serrano, Nuria
    Manuel Diaz-Cruz, Jose
    Esteban, Miquel
    ANALYTICA CHIMICA ACTA, 2017, 990 : 11 - 53
  • [48] STUDY OF THE REDUCTION-MECHANISM OF ISONICOTINAMIDE ON MERCURY-ELECTRODES
    MELLADO, JMR
    GALVIN, RM
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1989, 267 (1-2): : 221 - 230
  • [49] VOLTAGE FLUCTUATIONS AT SODIUM BETA''-ALUMINA MERCURY-ELECTRODES
    KUO, CK
    BROPHY, JJ
    SOLID STATE IONICS, 1987, 25 (2-3) : 193 - 197
  • [50] PROPERTIES OF AMPEROMETRIC HPLC DETECTORS BASED ON MERCURY-ELECTRODES
    JUST, P
    KARAKAPLAN, M
    HENZE, G
    SCHOLZ, F
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 345 (01): : 32 - 35