DETERMINATION OF AROMATICS IN JET AND DIESEL FUELS BY SUPERCRITICAL FLUID CHROMATOGRAPHY WITH FLAME IONIZATION DETECTION (SFC-FID) - A QUANTITATIVE STUDY

被引:29
|
作者
DISANZO, FP
YODER, RE
机构
[1] Mobile Research and Development Corporation, Paulsboro, NJ
[2] BP Americus, Cleveland, OH, 44128, Warrenville Center Road
关键词
D O I
10.1093/chromsci/29.1.4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The fluorescent indicator adsorption (FIA) method is the most commonly used industry method for the determination of total aromatics in light fuels. Alternative methods using supercritical fluid chromatography coupled with flame ionization detection (SFC-FID) have been proposed. Quantitative studies are performed on aromatics in jet and diesel fuel, using standard blends derived from gasoline, jet, and diesel fuels to determine the accuracy of SFC methods. The goal is to develop a simple method for use in a rapid, automated routine. To this end, a single column, one mobile phase under constant density, and no temperature programming or valve switching is used.
引用
收藏
页码:4 / 7
页数:4
相关论文
共 50 条
  • [41] Determination of Fatty Acid Methyl Esters by Gas Chromatography-Flame Ionization Detection: Response Mechanism and Quantitative Pattern
    Cui H.
    Yang H.
    Sun L.
    Ye Q.
    Ding C.
    Wang W.
    Ji T.
    Ma L.
    Zeng K.
    Yin Q.
    Shipin Kexue/Food Science, 2024, 45 (13): : 49 - 57
  • [42] QUANTITATIVE-DETERMINATION OF CANTHARIDIN IN BIOLOGICAL-MATERIALS USING CAPILLARY GAS-CHROMATOGRAPHY WITH FLAME IONIZATION DETECTION
    CARREL, JE
    DOOM, JP
    MCCORMICK, JP
    JOURNAL OF CHROMATOGRAPHY, 1985, 342 (02): : 411 - 415
  • [43] QUANTITATIVE-DETERMINATION OF NAPROXEN IN FORMULATED RAT FEED BY GAS CHROMATOGRAPHY-MASS SPECTROMETRY AND GAS CHROMATOGRAPHY-FLAME-IONIZATION DETECTION
    AMOS, B
    MARPLE, L
    SMITHERS, J
    MATIN, SB
    JOURNAL OF CHROMATOGRAPHY, 1981, 206 (01): : 151 - 157
  • [44] An Improved Validated Method for the Determination of Short-Chain Fatty Acids in Human Fecal Samples by Gas Chromatography with Flame Ionization Detection (GC-FID)
    Smith, Morganne
    Polite, Lee
    Christy, Andreas
    Edirisinghe, Indika
    Burton-Freeman, Britt
    Sandhu, Amandeep
    METABOLITES, 2023, 13 (11)
  • [45] The development of a method for the qualitative and quantitative determination of petroleum hydrocarbon components using thin-layer chromatography with flame ionization detection
    Wang, Shijie
    Guo, Guanlin
    Yan, Zengguang
    Lu, Guilan
    Wang, Qunhui
    Li, Fasheng
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (03) : 368 - 374
  • [46] Quantitative Determination of Short Chain Fatty Acids in Synthetic Feces Using Gas Chromatography with Flame Ionization Detection or Mass Spectrometry
    Abbiss, Hayley
    Shafaei, Armaghan
    Bannister, Mark
    Boyce, Mary C.
    JOURNAL OF CHEMICAL EDUCATION, 2023, 101 (01) : 113 - 119
  • [47] COMPARISON OF FLAME IONIZATION AND INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY FOR THE DETECTION OF ORGANOMETALLICS SEPARATED BY CAPILLARY SUPERCRITICAL-FLUID CHROMATOGRAPHY
    VELA, NP
    CARUSO, JA
    JOURNAL OF CHROMATOGRAPHY, 1993, 641 (02): : 337 - 345
  • [48] Determination of Phthalate Esters in Water and Liquid Pharmaceutical Samples by Dispersive Liquid-Liquid Microextraction (DLLME) and Gas Chromatography with Flame Ionization Detection (GC-FID)
    Zakharkiv, Igor
    Zui, Maryna
    Zaitsev, Vladimir
    ANALYTICAL LETTERS, 2020, 53 (10) : 1536 - 1553
  • [49] Quantitative Analysis of Flavor Volatiles in Beer Using Headspace Solid-Phase Microextraction and Gas Chromatography-Flame Ionization Detection (HS-SPME-GC-FID)
    Li, Hong
    Liu, Fang
    Kun-Farkas, Gabriella
    Kiss, Zsuzsanna
    JOURNAL OF THE AMERICAN SOCIETY OF BREWING CHEMISTS, 2015, 73 (03) : 261 - 265
  • [50] DETERMINATION OF AN ORGANOTIN STABILIZER IN A RIGID POLY(VINYL CHLORIDE) PLASTIC BY ONLINE SUPERCRITICAL-FLUID EXTRACTION AND CHROMATOGRAPHY WITH FORMIC-ACID MODIFIED CARBON-DIOXIDE AND FLAME IONIZATION DETECTION
    OUDSEMA, JW
    POOLE, CF
    HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1993, 16 (03): : 198 - 202