INVESTIGATION OF RADIOACTIVE COUNTING SAMPLES OF SELECTED RADIONUCLIDES IN VARIOUS LIQUID SCINTILLATORS

被引:6
|
作者
TERLIKOWSKADROZDZIEL, T
RADOSZEWSKI, T
机构
[1] The Radioisotope Research Centre
关键词
D O I
10.1016/0168-9002(92)90136-R
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This article presents some results of the investigation of radioactive counting samples prepared with the use of liquid scintillators. Liquid scintillation cocktails Atomlight (NEN) and Opti-phase HiSafe II (LKB) in standard glass vials of 20 ml volume were used. The counting efficiencies for several radionuclides in the above scintillators were compared. Two different experimental methods for measurement of the samples were applied: (1) The 4-pi-beta-gamma coincidence method with a liquid scintillator in the beta channel (for beta-gamma and EC-gamma emitters). In this case the counting efficiency was calculated according to the formula epsilon(beta) = N(c)/N(gamma). (2) The triple-double coincidence ratio (TDCR) method (for pure beta or EC emitters). In this case the counting efficiency was calculated as epsilon(D) = N(D)/N(O), where N(D) - the total number of double coincidences, N(O) - the number of disintegrations in the sample. The effect of the complexing agents HDEHP (diethylhexyl phosphoric acid) and EDTA (ethylenediaminetetraacetic acid) on the quality of the counting samples was studied. The application of the water solution of EDTA to prepare the counting samples of a few radionuclides improved both the counting efficiency and the stability of the samples. A slight quenching effect of HDEHP was observed.
引用
收藏
页码:100 / 103
页数:4
相关论文
共 50 条
  • [21] SIMULTANEOUS PREPARATION OF PRECIPITATE AND PLANCHET SAMPLES FOR RADIOACTIVE COUNTING
    BEETCH, EB
    PAULSON, BA
    CHEMIST-ANALYST, 1967, 56 (1-2) : 35 - &
  • [22] NOTE ON A POSSIBLE SOURCE OF ERROR IN COUNTING RADIOACTIVE SAMPLES
    SAUCIER, G
    DUGAL, LP
    CANADIAN JOURNAL OF BIOCHEMISTRY AND PHYSIOLOGY, 1959, 37 (05): : 721 - 723
  • [23] COUNTING EFFICIENCY OF SOME COMMERCIALLY AVAILABLE LIQUID SCINTILLATORS COMPARED
    GRAY, P
    VANREENEN, O
    POTGIETER, GM
    CLINICAL CHEMISTRY, 1980, 26 (13) : 1886 - 1887
  • [24] Radioactive nuclear beams studies using deuterated liquid scintillators
    Ojaruega, M.
    Becchetti, F. D.
    Jiang, Hao
    Amro, H.
    Golobish, M.
    Kolata, J. J.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 1336 - +
  • [25] RELATIONSHIP BETWEEN FLUORESCENCE INTENSITY AND COUNTING EFFICIENCY WITH LIQUID SCINTILLATORS
    LUKENS, HR
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1961, 12 (1-2): : 134 - &
  • [26] DETERMINATION OF RADIOACTIVE CALCIUM BY LIQUID SCINTILLATION COUNTING
    SARNAT, M
    JEFFAY, H
    ANALYTICAL CHEMISTRY, 1962, 34 (06) : 643 - &
  • [27] Rapid procedure for the analysis of radionuclides in liquid samples
    Parsa, Bahman
    Henitz, James
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2013, 245
  • [28] The sorption of selected radionuclides on various metal and polymeric materials
    Raber, E.
    Garrison, J.
    Oversby, V.
    Radioactive Waste Management and the Nuclear Fuel Cycle, 1983, 4 (01): : 41 - 52
  • [29] THE SORPTION OF SELECTED RADIONUCLIDES ON VARIOUS METAL AND POLYMERIC MATERIALS
    RABER, E
    GARRISON, J
    OVERSBY, V
    RADIOACTIVE WASTE MANAGEMENT AND ENVIRONMENTAL RESTORATION, 1983, 4 (01): : 41 - 52
  • [30] LIQUID SCINTILLATION COUNTING OF AQUEOUS SAMPLES
    GORDON, CF
    WOLFE, AL
    ANALYTICAL CHEMISTRY, 1960, 32 (04) : 574 - 574