METHODOLOGICAL ERRORS IN PRECISE MEASUREMENT OF GAMMA-RAY ENERGIES WITH GE DETECTORS

被引:0
|
作者
KISHIKAWA, T
机构
[1] Kumamoto University, Kumamoto-shi, 860, Kurokami
关键词
GE SEMICONDUCTOR DETECTORS; EXPERIMENTAL DATA; ENERGY DEPENDENCE; ENERGY RANGE; ENERGY CALIBRATION; GAMMA-RAY ENERGY; SECONDARY ENERGY STANDARD; ERRORS; PHOTOPEAK SHAPE FUNCTION; CENTROID; MOST PROBABLE PEAK-HEIGHT POSITION; PEAK DIFFERENCE RATE; GAP DIFFERENCE-RATE INDEX;
D O I
10.1080/18811248.1991.9731388
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Methodological errors in the precise measurement of gamma-ray energies with Ge detectors are examined basing on a model of photopeak shape function. The model revealed that the centroid of the normal distribution embedded in the phenomenal photopeak is to be compared with the energy scale. The peak difference rate is introduced to evaluate the peak difference, the essential quantity of experimentally giving secondary energy standard, relative to the energy difference. Varied value of the gap difference-rate index with several physical parameters has indicated that the secondary gamma-ray energies have a definite amount of methodological errors. A typical methodological error in the gamma-ray energy at around 300 keV is in the range of -263 +/- 125 approximately -54 +/- 123 eV (or -877 +/- 418 approximately -180 +/- 411 ppm). Commonly used "conventional" energy-calibration methods by the use of the most probable peak-height position have been reviewed. Origins of methodological errors are discussed. A new energy-calibration method using the centroid is proposed.
引用
收藏
页码:487 / 499
页数:13
相关论文
共 50 条
  • [21] MEASUREMENT OF GAMMA-RAY ENERGIES WITH ONE CRYSTAL
    MCINTYRE, JA
    HOFSTADTER, R
    PHYSICAL REVIEW, 1950, 78 (05): : 617 - 619
  • [22] MEASUREMENT OF GAMMA-RAY ENERGIES WITH A SCINTILLATION SPECTROMETER
    DERMATEOSIAN, E
    PHYSICAL REVIEW, 1951, 83 (01): : 223 - 223
  • [23] Precise measurement of pion-bump structure using future MeV gamma-ray detectors
    Liu, Jiahao
    Liu, Bing
    Yang, Ruizhi
    PHYSICAL REVIEW D, 2024, 110 (06)
  • [24] Development of segmented Ge detectors for future gamma-ray arrays
    Eberth, J
    Thomas, HG
    Weisshaar, D
    Becker, F
    Fiedler, B
    Skoda, S
    VonBrentano, P
    Gund, C
    Palafox, L
    Reiter, P
    Schwalm, D
    Habs, D
    Servene, T
    Schwengner, R
    Schnare, H
    Schulze, W
    Prade, H
    Winter, G
    Jungclaus, A
    Lingk, C
    Teich, C
    Lieb, KP
    PROGRESS IN PARTICLE AND NUCLEAR PHYSICS, VOL 38: 4(PI) HIGH RESOLUTION GAMMA RAY SPECTROSCOPY AND NUCLEAR STRUCTURE, 1997, 38 : 29 - 37
  • [25] GAMMA-RAY SPECTROSCOPY USING GE(LI) DETECTORS - NUCL
    CAMP, DC
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1970, : 1 - &
  • [26] ON ORIGIN OF LEAKAGE CURRENT IN GE(LI) GAMMA-RAY DETECTORS
    MCINTYRE, RJ
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1968, NS15 (05) : 6 - &
  • [27] GE(LI) GAMMA-RAY DETECTORS FOR ENVIRONMENTAL ACTIVITY MEASUREMENTS
    WALFORD, GV
    HEALTH PHYSICS, 1970, 19 (01): : 171 - +
  • [28] IMAGING EFFICIENCY OF GE AND NAI(TL) GAMMA-RAY DETECTORS
    STRAUSS, MG
    SHERMAN, IS
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1975, NS22 (01) : 331 - 343
  • [29] RELATIVE GAMMA-RAY INTENSITIES FOR CALIBRATION OF GE(LI) DETECTORS
    HNATOWICZ, V
    NUCLEAR INSTRUMENTS & METHODS, 1979, 161 (01): : 151 - 159
  • [30] MEASUREMENT OF GAMMA-RAY ENERGIES WITH 2 CRYSTALS IN COINCIDENCE
    HOFSTADTER, R
    MCINTYRE, JA
    PHYSICAL REVIEW, 1950, 78 (05): : 619 - 620