USE OF A COMBINED RIGHT VENTRICULAR EJECTION FRACTIONOXIMETRY CATHETER SYSTEM FOR CORONARY-BYPASS SURGERY

被引:5
|
作者
DORMAN, BH [1 ]
SPINALE, FG [1 ]
KRATZ, JM [1 ]
ALPERT, CC [1 ]
FORD, M [1 ]
机构
[1] MED UNIV S CAROLINA,DEPT CARDIOTHORAC SURG,CHARLESTON,SC 29425
关键词
VENTRICULAR EJECTION FRACTION; OXIMETRY; DUAL; BYPASS; CORONARY ARTERY; CRITICAL ILLNESS; MONITORING; HEART; RIGHT VENTRICULAR FUNCTION; CARDIAC OUTPUT; CATHETERIZATION; THERMODILUTION; PULSE OXIMETRY; CARDIAC EMERGENCIES;
D O I
10.1097/00003246-199212000-00008
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective. To evaluate the reproducibility and accuracy of a new pulmonary artery catheter system that provides both right ventricular ejection fraction and continuous venous oxygen saturation monitoring. Design: Criterion standard study. Setting. University medical center. Patients: A consecutive sample of ten patients undergoing elective coronary artery bypass surgery provided informed consent for the study. Exclusion criteria included emergency surgery or clinically important preoperative tricuspid regurgitation as assessed by echocardiography. None of the patient sample was excluded. Measurements: Catheter-derived mixed venous and arterial oximetry data were compared with simultaneous values obtained using conventional laboratory cooximetry methods. Measurements were performed before cardiopulmonary bypass and intermittently up to 48 hrs after cardiopulmonary bypass. The variability of cardiac output and computed right ventricular ejection fraction was also assessed concurrently with the oximetry analysis. Results: A significant correlation was observed for mixed venous oxygen saturation between catheter-derived and laboratory cooximetry data (r2 = .81, p < .01). Similarly, arterial oxygen saturation values obtained from pulse oximetry and laboratory values were significantly related (r2 = .81, p < .01). The coefficient of variation for each set of five repeated measurements for cardiac output was 8%, and for computed right ventricular ejection fraction, it was 16%. Conclusions: The combined catheter system provides the means to monitor both mixed venous oxygen saturation and right ventricular ejection fraction. These data provide a reliable and detailed assessment of cardiopulmonary function that should prove beneficial in the critical care setting.
引用
收藏
页码:1650 / 1656
页数:7
相关论文
共 50 条
  • [31] BALLISTOCARDIOGRAM AND CORONARY-BYPASS SURGERY
    SCHOTTELNDREIER, MAHW
    RODRIGO, F
    BIBLIOTHECA CARDIOLOGICA, 1976, (35) : 188 - 190
  • [32] CONCEPTS OF CORONARY-BYPASS SURGERY
    MILLS, NL
    OCHSNER, JL
    POSTGRADUATE MEDICINE, 1975, 57 (03) : 97 - 104
  • [33] BLOODLESS CORONARY-BYPASS SURGERY
    CLINE, RE
    JUDE, JR
    JOURNAL OF THE FLORIDA MEDICAL ASSOCIATION, 1979, 66 (10): : 1042 - 1043
  • [34] REALISM IN CORONARY-BYPASS SURGERY
    SPODICK, DH
    AMERICAN JOURNAL OF CARDIOLOGY, 1976, 38 (05): : 665 - 666
  • [35] A CONSENSUS ON CORONARY-BYPASS SURGERY
    RAHIMTOOLA, SH
    ANNALS OF INTERNAL MEDICINE, 1981, 94 (02) : 272 - 273
  • [36] CORONARY-BYPASS SURGERY - A REAPPRAISAL
    FREEMAN, Z
    FREEMAN, A
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF MEDICINE, 1982, 12 (04): : 309 - 320
  • [37] CEREBROVASCULAR ACCIDENTS AS AN IMMEDIATE COMPLICATION OF CORONARY-BYPASS SURGERY OR VENTRICULAR RESECTION
    HARRISON, EE
    SHELDON, S
    PUPELLO, DF
    BLANK, RH
    BESSONE, L
    STROKE, 1977, 8 (01) : 4 - 5
  • [38] LEFT-VENTRICULAR ECHOGRAMS BEFORE AND AFTER CORONARY-BYPASS SURGERY
    CORYA, BC
    RASMUSSEN, S
    BLACK, MJ
    FEIGENBAUM, H
    CLINICAL RESEARCH, 1976, 24 (03): : A213 - A213
  • [39] IMPROVEMENT IN RESTING VENTRICULAR-FUNCTION FOLLOWING CORONARY-BYPASS SURGERY
    TCHERVENKOV, CI
    SYMES, JF
    SNIDERMAN, AD
    LISBONA, R
    DERBEKYAN, VA
    NOVICK, RJ
    DOBELL, ARC
    MORIN, JE
    CIRCULATION, 1983, 68 (04) : 261 - 261
  • [40] THE EFFECT OF CORONARY-BYPASS SURGERY ON SEGMENTAL LEFT-VENTRICULAR FUNCTION
    ANDERSEN, PE
    THAYSSEN, P
    DANISH MEDICAL BULLETIN, 1984, 31 (06) : 503 - 507