MICRONUCLEUS TEST WITH CYCLOPHOSPHAMIDE USING MOUSE PERIPHERAL-BLOOD RETICULOCYTES

被引:19
|
作者
HATANAKA, Y [1 ]
KITAGAWA, Y [1 ]
TOYODA, Y [1 ]
KAWATA, T [1 ]
ANDO, N [1 ]
KAWABATA, Y [1 ]
IWAI, M [1 ]
ARIMURA, H [1 ]
机构
[1] GREEN CROSS CO,FUKUZAKI,HYOGO 67922,JAPAN
来源
MUTATION RESEARCH | 1992年 / 278卷 / 2-3期
关键词
CYCLOPHOSPHAMIDE; MICRONUCLEUS TEST; PERIPHERAL BLOOD RETICULOCYTES;
D O I
10.1016/0165-1218(92)90216-M
中图分类号
Q3 [遗传学];
学科分类号
071007 ; 090102 ;
摘要
The usefulness of the micronucleus test using supravital staining of peripheral blood reticulocytes with acridine orange was evaluated in two laboratories after administering cyclophosphamide (CYP) as a model chemical by intraperitoneal injection (i.p.) to CD-1 mice. The frequencies of micronucleated peripheral reticulocytes (MNRETs) increased dose-dependently at each sampling time. There were no significant differences in the results obtained with this new method by the two laboratories. Although the induction of MNRETs was delayed by about 24 h compared to that of micronucleated polychromatic erythrocytes (MNPCEs) in the bone marrow, the frequencies of MNRETs and MNPCEs were almost identical at each optical sampling time, 24 h for MNPCEs and 48 h for MNRETs. Therefore, it is concluded that this method is a suitable alternative to that using femoral marrow cells.
引用
收藏
页码:99 / 101
页数:3
相关论文
共 50 条
  • [41] EFFECTS OF BENZENE IN A MICRONUCLEUS TEST ON PERIPHERAL-BLOOD UTILIZING ACRIDINE ORANGE-COATED SLIDES
    HATAKEYAMA, Y
    NAKAJIMA, E
    ATAI, H
    SUZUKI, S
    MUTATION RESEARCH, 1992, 278 (2-3): : 193 - 195
  • [42] APPLICATION OF RAT PERIPHERAL RETICULOCYTES FOR THE MICRONUCLEUS ASSAY
    AWOGI, T
    KODAMA, Y
    SUZUKI, T
    HAYASHI, M
    ASITA, AO
    SOFUNI, T
    MUTATION RESEARCH, 1991, 253 (03): : 244 - 244
  • [43] THE SUITABILITY OF RAT PERIPHERAL-BLOOD IN SUBCHRONIC STUDIES FOR THE MICRONUCLEUS ASSAY
    ASANAMI, S
    SHIMONO, K
    SAWAMOTO, O
    KURISU, K
    UEJIMA, M
    MUTATION RESEARCH LETTERS, 1995, 347 (02): : 73 - 78
  • [44] Determination of micronucleus frequency by acridine orange fluorescent staining in peripheral blood reticulocytes of mice treated topically with different lubricant oils and cyclophosphamide
    Oliveira-Martins, C. R.
    Grisolia, C. K.
    GENETICS AND MOLECULAR RESEARCH, 2007, 6 (03) : 566 - 574
  • [45] FLOW CYTOMETRIC MICRONUCLEUS TEST WITH MOUSE PERIPHERAL ERYTHROCYTES
    HAYASHI, M
    NORPPA, H
    SOFUNI, T
    ISHIDATE, M
    MUTAGENESIS, 1992, 7 (04) : 257 - 264
  • [46] SIMPLIFIED MOUSE PERIPHERAL RETICULOCYTE MICRONUCLEUS TEST WITH DIMETHYLNITROSAMINE
    SATO, S
    TAKETOMI, M
    MORITA, T
    MUTATION RESEARCH, 1992, 278 (2-3): : 103 - 107
  • [47] A SEMI-AUTOMATED SCORING METHOD THAT MARKEDLY IMPROVES THE STATISTICAL POWER OF THE PERIPHERAL-BLOOD MICRONUCLEUS TEST
    CHOY, WN
    MACGREGOR, JT
    ENVIRONMENTAL MUTAGENESIS, 1985, 7 : 51 - 52
  • [48] MOUSE PERIPHERAL-BLOOD LYMPHOCYTES IN CULTURE
    FESTENSTEIN, H
    LANCET, 1968, 1 (7535): : 182 - +
  • [49] CULTURE OF MOUSE PERIPHERAL-BLOOD LYMPHOCYTES
    LUM, J
    GRIFFIN, JFT
    PROCEEDINGS OF THE UNIVERSITY OF OTAGO MEDICAL SCHOOL, 1978, 56 (03): : 88 - 89
  • [50] A comparison between mouse and fish micronucleus test using cyclophosphamide, mitomycin C and various pesticides
    Grisolia, CK