ELECTROTHERMAL AAS DETERMINATION OF BISMUTH, ANTIMONY AND TIN IN HIGH-PURITY WO3

被引:11
|
作者
HAVEZOV, I [1 ]
JORDANOV, N [1 ]
ORTNER, HM [1 ]
机构
[1] MET WERK PLANSEE GMBH, A-6600 REUTTE, AUSTRIA
来源
关键词
D O I
10.1007/BF00321667
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Four methods for the bulk trace determination of Bi, Sb and Sn in WO3 were developed and tested. In all cases, the final determination is carried out by graphite furnace atomic absorption spectrophotometry. The limits of detection range from 1-mu-g/g for a very fast and simple method to 50 ng/g for a method comprising a trace-matrix separation by sorption and complexation on activated carbon powder loaded with TMDTC. A way of preparation of standard reference WO3-samples doped with varying amounts of Bi, Sb and Sn traces is also described.
引用
收藏
页码:871 / 873
页数:3
相关论文
共 50 条
  • [31] DETERMINATION OF IMPURITIES IN HIGH-PURITY MATERIALS BY INVERSE VOLTAMMETRY .3. DETERMINATION OF ZINC IN ANTIMONY CHLORIDES
    BATYCKA, H
    LUKASZEWSKI, Z
    CHEMIA ANALITYCZNA, 1977, 22 (04): : 725 - 732
  • [32] DETERMINATION OF COPPER, LEAD AND CADMIUM IN HIGH-PURITY ZINC BY METAL FURNACE AAS
    FUDAGAWA, N
    HIOKI, A
    KUBOTA, M
    KAWASE, A
    BUNSEKI KAGAKU, 1986, 35 (08) : T62 - T66
  • [33] PREPARATION OF HIGH-PURITY COLLOIDAL ANTIMONY
    GALINOS, AG
    ISSOPOULOS, PB
    REVUE ROUMAINE DE CHIMIE, 1976, 21 (02) : 229 - 230
  • [34] INTERFERENCES IN DETERMINATION OF TRACE-ELEMENTS IN HIGH-PURITY TIN
    MAENHAUT, W
    ADAMS, F
    HOSTE, J
    JOURNAL OF RADIOANALYTICAL CHEMISTRY, 1973, 16 (01): : 39 - 55
  • [35] DETERMINATION OF TIN IN HIGH-PURITY ARSENIC TRICHLORIDE BY INVERSE VOLTAMMETRY
    CISZEWSKI, A
    CHEMIA ANALITYCZNA, 1977, 22 (03): : 571 - 573
  • [36] Low-Loss, High-Purity (TeO2)0.75(WO3)0.25 Glass
    Moiseev, A. N.
    Dorofeev, V. V.
    Chilyasov, A. V.
    Pimenov, V. G.
    Kotereva, T. V.
    Kraev, I. A.
    Ketkova, L. A.
    Kosolapov, A. F.
    Plotnichenko, V. G.
    Koltashev, V. V.
    INORGANIC MATERIALS, 2011, 47 (06) : 665 - 669
  • [37] Preparation of high-purity antimony oxychloride from high-arsenic refined bismuth dust
    Zheng, Ya-Jie
    Teng, Hao
    Bai, Meng
    Zhongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Central South University (Science and Technology), 2011, 42 (06): : 1549 - 1554
  • [38] Low-loss, high-purity (TeO2)0.75(WO3)0.25 glass
    A. N. Moiseev
    V. V. Dorofeev
    A. V. Chilyasov
    V. G. Pimenov
    T. V. Kotereva
    I. A. Kraev
    L. A. Ketkova
    A. F. Kosolapov
    V. G. Plotnichenko
    V. V. Koltashev
    Inorganic Materials, 2011, 47 : 665 - 669
  • [39] SPECTROPHOTOMETRIC DETERMINATION OF AN ARSENIC IMPURITY IN GALLIUM AND ANTIMONY CHLORIDES OF HIGH-PURITY
    GORYUSHI.VG
    ROMANOVA, EV
    RAZUMOVA, LS
    ZHURNAL ANALITICHESKOI KHIMII, 1973, 28 (03): : 601 - 603
  • [40] DETERMINATION OF TIN, ANTIMONY AND BISMUTH IN COPPER BY METAL FURNACE AAS AFTER COPRECIPITATION WITH MANGANESE-DIOXIDE
    KURATA, N
    HARADA, Y
    FURUNO, G
    BUNSEKI KAGAKU, 1990, 39 (05) : 289 - 294