JOINT MOBILITY MEASUREMENTS - RELIABILITY OF A STANDARDIZED METHOD

被引:19
|
作者
DIJKSTRA, PU
DEBONT, LGM
VANDERWEELE, LT
BOERING, G
机构
[1] Department of Oral and Maxillofacial Surgery, University Hospital, Groningen
来源
CRANIO-THE JOURNAL OF CRANIOMANDIBULAR & SLEEP PRACTICE | 1994年 / 12卷 / 01期
关键词
D O I
10.1080/08869634.1994.11677994
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Assessment of hypermobility and hypomobility is frequently performed visually with all its limitations. In this study, a standardized joint mobility measurement method is suggested, and its reliability is tested. The maximal range of motion of passive digit five hyperextension, passive thumb apposition to the wrist, active elbow and knee hyperextension, active ankle dorsal flexion and trunk flexion was measured in 30 healthy subjects. All measurements were performed bilaterally, except for trunk flexion. Three experienced observers performed the measurements according to a rigidly standardized protocol, using appropriate goniometers and rulers. During one measurement session each observer measured each subject. Two consecutive measurement sessions were organized. Analysis of variance, with subject and time as explaining variables, was performed on the data obtained. The inter-observer variability ranged from 1.42 degrees (left knee hyperextension) to 4.05 mm (right thumb apposition) in the first measurement session and from 1.35 degrees (left knee hyperextension) to 4.58 degrees (right digit five hyperextension) in the second measurement session. The intra-observer variability ranged for observer A from 0.75 degrees (left knee hyperextension) to 3.67 mm (left thumb apposition), and from 0.93 degrees (left knee hyperextension) to 3.88 degrees (left digit five hyperextension) for observer B. Observer C ranged from 0.71 degrees (left knee hyperextension) to 4.01 mm (right thumb apposition). Based on the results of this study, the authors conclude that joint mobility can be measured reliably and accurately with the presented simple tools. The joint mobility measurement method reveals the mobility for each separate joint and provides a basis for comparison between individuals and between groups of individuals, both in the case of single and generalized joint mobility assessment.
引用
收藏
页码:52 / 57
页数:6
相关论文
共 50 条
  • [21] Reliability of metatarsophalangeal and ankle joint torque measurements by an innovative device
    Man, Hok-Sum
    Leung, Aaron Kam-Lun
    Cheung, Jason Tak-Man
    Sterzing, Thorsten
    GAIT & POSTURE, 2016, 48 : 189 - 193
  • [22] GONIOMETRIC RELIABILITY IN A CLINICAL SETTING - SUBTALAR AND ANKLE JOINT MEASUREMENTS
    ELVERU, RA
    ROTHSTEIN, JM
    LAMB, RL
    PHYSICAL THERAPY, 1988, 68 (05): : 672 - 677
  • [23] RELIABILITY OF MEASUREMENTS OF LUMBAR SPINE SAGITTAL MOBILITY OBTAINED WITH THE FLEXIBLE CURVE
    YOUDAS, JW
    SUMAN, VJ
    GARRETT, TR
    JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 1995, 21 (01): : 13 - 20
  • [24] Reliability and minimal detectable change of thoracoabdominal mobility measurements using photogrammetry
    Sarro, Karine J.
    Mombrini, Camila L.
    Tonole, Thais B.
    PHYSIOTHERAPY THEORY AND PRACTICE, 2018, 34 (09) : 730 - 739
  • [25] Reliability of first ray position and mobility measurements in experienced and inexperienced examiners
    Shirk, C
    Sandrey, MA
    Erickson, M
    JOURNAL OF ATHLETIC TRAINING, 2006, 41 (01) : 93 - 99
  • [26] Reliability and Validity of Optoelectronic Method for Biophotonical Measurements
    Karpienko, Katarzyna
    Wrobel, Maciej S.
    Urniaz, Rafal
    BIOPHOTONICS - RIGA 2013, 2013, 9032
  • [27] RELIABILITY OF METABOLISM MEASUREMENTS BY THE CLOSED CIRCUIT METHOD
    HARMON, FL
    JOURNAL OF APPLIED PHYSIOLOGY, 1953, 5 (12) : 773 - 778
  • [28] Three-dimensional Motion Analysis of Sacroiliac Joint Mobility: A Reliability Study
    Parchekouhi, Ahmad Bahramian
    Karimi, Noureddin
    Yousefi, Mohammad
    Ghomsheh, Farhad Tabatabai
    Rahnama, Leila
    IRANIAN RED CRESCENT MEDICAL JOURNAL, 2023, 25 (01)
  • [29] Reliability design method for interference joint in mechanical engineering
    Xiu, S. C.
    Feng, Q.
    Gao, S. Q.
    MATERIALS AND PRODUCT TECHNOLOGIES, 2008, 44-46 : 773 - 778
  • [30] Intra- and inter-observer reliability of a new standardized diagnostic method using SPECT/CT in patients with osteochondral lesions of the ankle joint
    Hassink, Genevieve
    Testa, Enrique A.
    Leumann, Andre
    Huegle, Thomas
    Rasch, Helmut
    Hirschmann, Michael T.
    BMC MEDICAL IMAGING, 2016, 16