Corrosion protection of tank product side bottoms

被引:2
|
作者
Lyublinski, E. Ya. [1 ]
Kuznetsov, Yu. I. [2 ]
Schultz, Marcelo [3 ]
Vaks, Yefim [1 ]
机构
[1] Northern Technol Int Corp, 23205 Mercantile Rd, Beachwood, OH 44122 USA
[2] Russian Acad Sci, AN Frumkin Inst Phys Chem & Electrochem, Moscow 119071, Russia
[3] Petrobras SA, BR-20031170 Rio De Janeiro, RJ, Brazil
关键词
corrosion; inhibitor; cathodic protection; storage tanks; efficiency; service life;
D O I
10.17675/2305-6894-2013-2-2-150-161
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Corrosion of storage tank product side bottoms and tanks of tankers is one of the most critical problems worldwide in oil and gas industry. The protection methods currently in use include cathodic protection systems (CPS) and soluble corrosion inhibitors (SCI). Crude oils contain water and various soluble inorganic and organic compounds. During the storage and transportation of crude oil, the sediment aqueous solutions (SAS) contains high concentrations of H2S, Cl-, SO42-, etc. The corrosion rates of storage tanks and tanks of tanker bottoms can vary from 0.05 to 3.0 mm per year. The service life of tank bottoms is unpredictable and can range from 2 to 20 years. In many cases, traditional corrosion protection systems (cathodic protection, coatings, and inhibitors) are not efficient enough, have short service life, or cannot be applied. This paper describes a new multistage corrosion protection system that combines different types of soluble corrosion inhibitors and cathodic protection systems. Together they achieve synergistic effects that can decrease the inhibitor protection concentration 3- to 6-fold and the current density 2-to 5-fold. This results in an increased service life of the corrosion protection method.
引用
收藏
页码:150 / 161
页数:12
相关论文
共 50 条
  • [41] CORROSION DETECTION IN STORAGE TANK BOTTOMS VIA OMNI-DIRECTIONAL MAGNETOSTRICTIVE GUIDED WAVE INSPECTION SYSTEM
    Chen, Xin
    Cobb, Adam
    Vinogradov, Sergey
    PROCEEDINGS OF 2022 49TH ANNUAL REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, QNDE2022, 2022,
  • [42] Environmental protection through automated remote monitoring of fuel storage tank bottoms using electric a resistance probes
    Welsh, RA
    Benefield, J
    MATERIALS PERFORMANCE, 2006, 45 (03) : 38 - 40
  • [43] GLASS-MELTING TANK BOTTOMS .2.
    BOGGUM, PP
    SCHULTE, K
    GLASS INDUSTRY, 1979, 60 (03): : 18 - 20
  • [44] Electrochemical properties and corrosion protection of stainless steel for hot water tank
    Seong-Jong Kim
    Seok-Ki Jang
    Jeong-Il Kim
    Korean Journal of Chemical Engineering, 2004, 21 : 739 - 745
  • [45] FUEL STORAGE - INFORMATION ON TANK MATERIALS AND POSSIBILITIES OF PROTECTION AGAINST CORROSION
    HORMANN, R
    CHEMISCHE TECHNIK, 1971, 23 (4-5): : 267 - &
  • [47] Electrochemical properties and corrosion protection of stainless steel for hot water tank
    Kim, SJ
    Jang, SK
    Kim, JI
    KOREAN JOURNAL OF CHEMICAL ENGINEERING, 2004, 21 (03) : 739 - 745
  • [48] FILTER PRESS EFFECTIVE, ECONOMICAL IN RECYCLING TANK BOTTOMS
    OBERG, BD
    OIL & GAS JOURNAL, 1986, 84 (26) : 75 - 78
  • [49] Effect of ZnO as corrosion product on corrosion behavior of zinc-iron corrosion protection systems
    Feng, Yixuan
    Wang, Lida
    Yang, Zhengqing
    Ma, Qian
    He, Dandan
    Xu, Kaixin
    Zhang, Han
    Zhang, Piji
    Sun, Wen
    Liu, Guichang
    CORROSION SCIENCE, 2024, 227
  • [50] CONSIDER FRP LININGS INSTEAD OF REPLACING STORAGE TANK BOTTOMS
    LEBLEU, JB
    HUMMEL, B
    HYDROCARBON PROCESSING, 1995, 74 (03): : 83 - +