PLOIDY PATTERN AND CELL-CYCLE IN BREAST-CANCER AS DETECTED BY IMAGE-ANALYSIS AND FLOW-CYTOMETRY

被引:16
|
作者
LUZI, P [1 ]
BRUNI, A [1 ]
MANGIAVACCHI, P [1 ]
CEVENINI, G [1 ]
MARINI, D [1 ]
TOSI, P [1 ]
机构
[1] UNIV SIENA,INST PATHOL ANAT & HISTOL,I-53100 SIENA,ITALY
来源
CYTOMETRY | 1994年 / 18卷 / 02期
关键词
DNA CONTENT; CELL CYCLE; IMAGE ANALYSIS; FLOW CYTOMETRY; BREAST CANCER;
D O I
10.1002/cyto.990180205
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Both image analysis (IA) and flow cytometry (FCM) may be applied to detect ploidy pattern and cell cycle fractions. However, they have different performance characteristics and may yield different results. The two approaches are applied in this study to 66 breast cancers: IA on imprints and FCM on fresh tissue. The percent coefficient of variation (CV) ranged from 2.0 to 7.0 (mean 5.5; SD 1.1) in IA and from 2.0 to 7.0 (mean 4.4; SD 1.1) in FCM. The values were well correlated. With regard to ploidy pattern, the agreement between the two methods was 92.4%; disagreements were due to four cases being aneuploid by IA but not detected by FCM and one case being aneuploid by IA but tetraploid by FCM. This suggests that IA is capable of detecting aneuploidy with more sensitivity than FCM. In diploid cases, the percent values of cells in G0/G1, S-phase (SPF), and G2M phase were concordant and well correlated. In aneuploid cases, IA was more sensitive than FCM in detecting aneuploid fraction as well as G2M phase, whereas FCM was more sensitive than IA in detecting SPF. A good correlation was found between the DNA indexes (Dls) obtained with the two methods. (C) 1994 Wiley-Liss, Inc.
引用
收藏
页码:79 / 87
页数:9
相关论文
共 50 条
  • [31] A FLOW-CYTOMETRY STUDY OF THE CELL-CYCLE AND OF PLOIDY LEVELS IN PHYSARUM-POLYCEPHALUM MYXAMOEBAE AND PLASMODIA
    TURNER, HM
    MOHBERG, J
    GOODMAN, EM
    MICROBIOS, 1981, 32 (127) : 29 - 36
  • [32] AN INVESTIGATION OF DIFFERENT METHODS OF CELL-CYCLE ANALYSIS BY FLOW-CYTOMETRY IN RECTAL-CANCER
    SCOTT, N
    CROSS, D
    PLUMB, MI
    DIXON, MF
    QUIRKE, P
    BRITISH JOURNAL OF CANCER, 1992, 65 (01) : 8 - 10
  • [33] RELATIONSHIP OF DNA-PLOIDY TO HISTOLOGY AND PROGNOSIS IN RHABDOMYOSARCOMA - COMPARISON OF FLOW-CYTOMETRY AND IMAGE-ANALYSIS
    KILPATRICK, SE
    TEOT, LA
    GEISINGER, KR
    MARTIN, PL
    SHUMATE, DK
    ZBIERANSKI, N
    RUSSELL, GB
    FLETCHER, CDM
    CANCER, 1994, 74 (12) : 3227 - 3233
  • [34] RELATIONSHIP OF DNA-PLOIDY TO HISTOLOGY AND PROGNOSIS IN RHABDOMYOSARCOMA - COMPARISON OF FLOW-CYTOMETRY AND IMAGE-ANALYSIS
    KILPATRICK, SE
    TEOT, LA
    GEISINGER, KR
    MARTIN, PL
    SHUMATE, DK
    ZBIERANSKI, N
    FLETCHER, CDM
    LABORATORY INVESTIGATION, 1994, 70 (01) : A8 - A8
  • [35] COMPARISON OF PLOIDY ANALYSIS BY FLOW-CYTOMETRY AND IMAGE-ANALYSIS IN HYDATIDIFORM MOLE AND NON-MOLAR ABORTION
    JEFFERS, MD
    MICHIE, BA
    OAKES, SJ
    GILLAN, JE
    HISTOPATHOLOGY, 1995, 27 (05) : 415 - 421
  • [36] PREPARATION OF HUMAN CORNEAL EPITHELIUM FOR CELL-CYCLE ANALYSIS BY FLOW-CYTOMETRY
    BURNS, ER
    SHOCK, JP
    ROBERSON, M
    HINSON, WG
    PIPKIN, JL
    ANSON, JF
    ANATOMICAL RECORD, 1985, 211 (03): : A29 - A30
  • [37] UPDATE ON THE CONCEPT OF THE CELL-CYCLE - THE CONTRIBUTION OF FLOW-CYTOMETRY
    RONOT, X
    ADOLPHE, M
    BIOLOGY OF THE CELL, 1986, 58 (02) : 113 - 119
  • [38] DNA-PLOIDY OF TRANSITIONAL-CELL CARCINOMA FROM ARCHIVAL TISSUE - COMPARISION OF FLOW-CYTOMETRY AND IMAGE-ANALYSIS
    TETU, B
    ALLARD, P
    FRADET, Y
    COTE, C
    ROBERGE, N
    ROY, G
    BERNIER, G
    GUILLAUD, P
    LABORATORY INVESTIGATION, 1994, 70 (01) : A84 - A84
  • [39] AUTOMATED RETICULOCYTE COUNTING BY IMAGE-ANALYSIS AND FLOW-CYTOMETRY
    HACKNEY, JR
    CEMBROWSKI, GS
    PRYSTOWSKY, MB
    KANT, JA
    LABORATORY MEDICINE, 1989, 20 (08) : 551 - 555
  • [40] DNA-PLOIDY MEASUREMENTS IN PROSTATE-CANCER - DIFFERENCES BETWEEN IMAGE-ANALYSIS AND FLOW-CYTOMETRY AND CLINICAL IMPLICATIONS
    PINDUR, A
    CHAKRABORTY, S
    WELCH, DG
    WHEELER, TM
    PROSTATE, 1994, 25 (04): : 189 - 198