Determination of ceftazidime and impurities using high performance liquid chromatography

被引:0
|
作者
Jiang Enzhu [1 ,2 ,3 ]
Hu Changqin [1 ]
机构
[1] Natl Inst Control Pharmaceut & Biol Prod, Beijing 100050, Peoples R China
[2] Chinese Acad Med, Inst Med Biotechnol, Beijing 100050, Peoples R China
[3] Peking Union Med Coll, Beijing 100050, Peoples R China
关键词
high performance liquid chromatography HPLC; gradient elution; ceftazidime impurities;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A high performance liquid chromatographic HPLC method for the determination of ceftazidime and impurities in ceftazidime drug was developed and verified. An Alltima C18 column 250 mm x 4. 6 mm 5 mu m was used as the analysis column. Acetonitrile and phosphate buffer 22. 6 g/L aqueous solution of ammonium dihydrogen phosphate adjusted to pH 3. 9 with 10% v/v phosphoric acid were used as mobile phases with gradient elution at a flow rate of 1. 3 mL/min. The column temperature was kept at 35 degrees C and the detection wavelength was set at 255 nm. Fourteen impurities could be well separated. The assay exhibited a good linearity in the ceftazidime concentration range of 0. 267 - 1 069 mu g/mL with a correlation coefficient of 1. 000 0. The limits of the quantitation and qualification of ceftazidime were 3. 1 ng and 0. 93 ng respectively. The relative standard deviations RSDs of the interday and intraday n = 3 determinations at three concentration levels were 0. 72% and 0. 91% respectively. At 4 degrees C ang under darkness ceftazidime solution was stable for 24 h. The developed method is superior to the counterparts in British and Japanese pharmacopeias in the number of the impurities separated and detected.
引用
收藏
页码:75 / 79
页数:5
相关论文
共 50 条
  • [41] DETERMINATION OF DEGRADATION PRODUCTS AND IMPURITIES OF AMOXICILLIN CAPSULES USING TERNARY GRADIENT ELUTION HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    FONG, GWK
    MARTIN, DT
    JOHNSON, RN
    KHO, BT
    JOURNAL OF CHROMATOGRAPHY, 1984, 298 (03): : 459 - 472
  • [42] Simultaneous determination of rocuronium and its eight impurities in pharmaceutical preparation using high-performance liquid chromatography with amperometric detection
    Blaewicz, Agata
    Fijalek, Zbigniew
    Warowna-Grzeskiewicz, Malgorzata
    Boruta, Magdalena
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1149 (01) : 66 - 72
  • [44] Determination of pravastatin by high performance liquid chromatography
    Siekmeier, R
    Gross, W
    März, W
    INTERNATIONAL JOURNAL OF CLINICAL PHARMACOLOGY AND THERAPEUTICS, 2000, 38 (09) : 419 - 425
  • [45] High performance liquid chromatography determination of formitol
    Foroughifar, N
    Mobinikhaledi, A
    Tajbakhsh, M
    Naeimi, H
    ASIAN JOURNAL OF CHEMISTRY, 2002, 14 (02) : 1101 - 1103
  • [46] Determination of lysinoalamine by high performance liquid chromatography
    Moret, S.
    Cherubin, S.
    Rodriguez-Estrada, M.T.
    Lercker, G.
    HRC Journal of High Resolution Chromatography, 1994, 17 (12):
  • [47] Determination of Kanamycin by High Performance Liquid Chromatography
    Zhang, Xingping
    Wang, Jiujun
    Wu, Qinghua
    Li, Li
    Wang, Yun
    Yang, Hualin
    MOLECULES, 2019, 24 (10)
  • [48] Determination of fluoroquinolone by high performance liquid chromatography
    Du, LM
    Wei, HQ
    Zhang, JY
    Zhang, QP
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2003, 31 (05) : 637 - 637
  • [49] Simultaneous determination of econazole nitrate, main impurities and preservatives in cream formulation by high performance liquid chromatography
    Gaona-Galdos, Angel Arturo
    Garcia, Pedro Lopez
    Aurora-Prado, Maria Segunda
    Rocha Miritello Santoro, Maria Ines
    Maria Kedor-Hackmann, Erika Rosa
    TALANTA, 2008, 77 (02) : 673 - 678
  • [50] DETERMINATION OF IMPURITIES IN DEXTROPROPOXYPHENE HYDROCHLORIDE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY ON DYNAMICALLY MODIFIED SILICA
    KRYGER, S
    HELBOE, P
    JOURNAL OF CHROMATOGRAPHY, 1991, 539 (01): : 186 - 192