Filtration Efficiency and Pressure Drop Performance of Ceramic Partial Wall Flow Diesel Particulate Filters

被引:27
|
作者
Basu, Sumit [1 ]
Henrichsen, Matthew [2 ]
Tandon, Pushkar [3 ]
He, Suhao [3 ]
Heibel, Achim [3 ]
机构
[1] Cummins Inc, Columbus, IN 47201 USA
[2] Cummins Emiss Solut, Columbus, IN USA
[3] Corning Inc, Corning, NY 14831 USA
关键词
D O I
10.4271/2013-01-9072
中图分类号
U [交通运输];
学科分类号
08 ; 0823 ;
摘要
A simple 1-dimensional filter model, with symmetric and asymmetric channels, has been developed to investigate the fundamental behavior and performance of ceramic partial diesel particulate filters (PFs). The governing equations of mass and momentum are similar to those of a full DPF [(7) under bar, (15) under bar]. A standard DPF with the plugs at its inlet face removed has been referred to as a 'rear-plugged PF' while, one with the plugs at the outlet face removed has been referred to as a 'frontplugged PF' in the present study. Removal of some of the plugs from a standard ceramic DPF reduces the (i) overall pressure drop (Delta P) across the filter, (ii) filtration efficiency (FE) of the DPF, and (iii) manufacturing cost. Partial filters stand a high chance of being deployed in diesel exhaust after-treatment systems for the emerging markets (Brazil, Russia, India, China) that follow Euro 4 emission regulations. The model has been used for predicting the pressure drop and filtration efficiency of the PF for a variety of situations and practical filter sizes. The effects of filter length, soot load, channel asymmetry, mass flow rate, wall permeability and multi-staging of filters on the pressure drop and filtration efficiency performance of the PF have been studied. An iterative approach to simulating a real-world non-uniform soot layer, instead of the uniform layer commonly assumed in DPF models, has been proposed. A standard DPF, front-plugged PF, and a rear-plugged PF have been modeled and the differences in their fundamental behavior are discussed. The model performance has been demonstrated to be reasonably similar to that of an existing 3-dimensional simulation. The filtration efficiency of and pressure drop across PFs have been predicted at various soot loads for filter sizes typical of light-duty diesel applications. A method to model DPFs with any fraction of the inlet/outlet faces plugged has been proposed.
引用
收藏
页码:877 / 893
页数:17
相关论文
共 50 条
  • [41] Filtration modelling in wall-flow particulate filters of low soot penetration thickness
    Ramon Serrano, Jose
    Climent, Hector
    Piqueras, Pedro
    Angiolini, Emanuele
    ENERGY, 2016, 112 : 883 - 898
  • [42] A mathematical model for the dynamic particulate filtration in diesel foam filters
    Pontikakis, GN
    Koltsakis, GC
    Stamatelos, AM
    PARTICULATE SCIENCE AND TECHNOLOGY, 1999, 17 (03) : 179 - 200
  • [43] Experimental and computational approach to the transient behaviour of wall-flow diesel particulate filters
    Jose Torregrosa, Antonio
    Ramon Serrano, Jose
    Piqueras, Pedro
    Garcia-Afonso, Oscar
    ENERGY, 2017, 119 : 887 - 900
  • [44] Catalytic wall-flow filters for the abatement of diesel particulate: regeneration parameters study
    Cauda, E.
    Fino, D.
    Saracco, G.
    Specchia, V.
    TOPICS IN CATALYSIS, 2007, 45 (1-4) : 125 - 129
  • [45] Catalytic wall-flow filters for the abatement of diesel particulate: regeneration parameters study
    E. Cauda
    D. Fino
    G. Saracco
    V. Specchia
    Topics in Catalysis, 2007, 45 : 125 - 129
  • [46] The effects of soot properties on the regeneration behaviour of wall-flow diesel particulate filters
    Law, MC
    Clarke, A
    Garner, CP
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART D-JOURNAL OF AUTOMOBILE ENGINEERING, 2004, 218 (D12) : 1513 - 1524
  • [47] Composite fibrous filters for nano-aerosol filtration: Pressure drop and efficiency model
    Thomas, D.
    Pacault, S.
    Charvet, A.
    Bardin-Monnier, N.
    Appert-Collin, J. -C.
    SEPARATION AND PURIFICATION TECHNOLOGY, 2019, 215 : 557 - 564
  • [48] Numerical simulation for flow and pressure drop characteristics in asymmetrical channels of diesel particulate filter
    Li Z.-J.
    Wang N.
    Zhang L.-Q.
    Huang Q.-J.
    Wei S.-K.
    Zhang Y.-K.
    1892, Editorial Board of Jilin University (46): : 1892 - 1899
  • [49] Filtration Efficiency of Functionalized Ceramic Foam Filters for Aluminum Melt Filtration
    Voigt, Claudia
    Jaeckel, Eva
    Taina, Fabio
    Zienert, Tilo
    Salomon, Anton
    Wolf, Gotthard
    Aneziris, Christos G.
    Le Brun, Pierre
    METALLURGICAL AND MATERIALS TRANSACTIONS B-PROCESS METALLURGY AND MATERIALS PROCESSING SCIENCE, 2017, 48 (01): : 497 - 505
  • [50] Modeling the filtration performance of ceramic filters over transient cycles of natural gas and diesel engines
    Wang, Yujun
    Ghosh, Rajat Subhra
    Gong, Jian
    Nikodem, Astrid
    Kutschi, Susanne
    Zokoe, James
    Xue, Eric Jian
    Wang, Zhuqi
    Honda, Takahiro
    Wells, Alexander
    Rahman, Shahidur M.
    Cunningham, Michael J.
    APPLIED ENERGY, 2023, 337