COMPARISON OF THE EVAPORATIVE LIGHT-SCATTERING DETECTOR (ELSD) AND REFRACTIVE-INDEX DETECTOR (RID) IN LIPID ANALYSIS

被引:63
|
作者
HOPIA, AI
OLLILAINEN, VM
机构
[1] University of Helsinki, Department of Applied Chemistry and Microbiology, Food Chemistry Division, SF-00710, Helsinki
来源
JOURNAL OF LIQUID CHROMATOGRAPHY | 1993年 / 16卷 / 12期
关键词
D O I
10.1080/10826079308019586
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The properties of an evaporative light scattering detector (ELSD) and a refractive index detector (RID) in isocratic HPLC analysis of lipids are compared. The effect of molecular structure, especially the unsaturation level, on the detector response is studied using eight different lipid standards. Linearity and sensitivity are compared. Quantitation of an unknown sample is also performed. The sensitivity of the ELSD was slightly better than that of the RID, the detector limits of triolein being 30 ng/injection and 50 ng/injection, respectively. The linearity of the ELSD was considered only approximate compared with that of the RID the response factors of the calibration curves being 0.9554 and 0.9999, respectively. The effect of the molecular structure on the detector response was higher with the RID than with the ELSD. The relative standard deviation (SD%) of responses was 23% for the RID and 12% for the ELSD. The unsaturation level had a greater effect on the detector response of the RID than on that of the ELSD. This study indicates that a standard deviation (SD) of at least 13% is to be expected with the ELSD and an even higher SD with the RI detector when quantitating heterogeneous mixtures or unknown compounds.
引用
收藏
页码:2469 / 2482
页数:14
相关论文
共 50 条
  • [41] Fatty acids by high-performance liquid chromatography and evaporative light-scattering detector
    Bravi, Elisabetta
    Perretti, Giuseppe
    Montanari, Luigi
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1134 (1-2) : 210 - 214
  • [42] Adaptation of an evaporative light-scattering detector to micro and capillary liquid chromatography and response assessment
    Gaudin, K
    Baillet, A
    Chaminade, P
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1051 (1-2) : 43 - 51
  • [43] Evaluation of evaporative light-scattering detector for combinatorial library quantitation by reversed phase HPLC
    Fang, LL
    Wan, M
    Pennacchio, M
    Pan, JM
    JOURNAL OF COMBINATORIAL CHEMISTRY, 2000, 2 (03): : 254 - 257
  • [44] LIQUID-CHROMATOGRAPHY DETERMINATION OF LIPOSOME COMPONENTS USING A LIGHT-SCATTERING EVAPORATIVE DETECTOR
    JAASKELAINEN, I
    URTTI, A
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1994, 12 (08) : 977 - 982
  • [45] Effects of Drift Tube and Nebulizing Gas Temperatures on the Response of Evaporative Light-Scattering Detector
    Boulahjar, Rajaa
    Slimani, Rachid
    El Haddad, Mohammadine
    Hmyene, Aziz
    El Antri, Said
    Akssira, Mohamed
    Dreux, Michel
    Lazar, Said
    ANALYTICAL LETTERS, 2009, 42 (09) : 1310 - 1320
  • [46] Determination of bisphenol analogues in food-contact plastics using diode array detector, charged aerosol detector and evaporative light-scattering detector
    Wang, Huiyu
    Song, Shanjun
    Shao, Mingwu
    Gao, Yan
    Yang, Chen
    Li, Ya
    Wang, Weihua
    He, Yajuan
    Li, Penghui
    ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY, 2019, 186
  • [48] Separation of anions on porous graphitized carbon (PGC) phase using evaporative light scattering detector (ELSD).
    Mercier, JP
    Chaimbault, P
    Elfakir, C
    Dreux, M
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1997, 214 : 30 - ANYL
  • [49] HPLC Analysis of Egg Yolk Phosphatidylcholine by Evaporative Light Scattering Detector
    Zhou Jing
    Hu Xianmei
    Wang Tianxin
    Liang Hao
    Yuan Qipeng
    CHINESE JOURNAL OF CHEMICAL ENGINEERING, 2012, 20 (04) : 665 - 672