Intelligent implants. Joint replacement implants with integrated electronic sensors

被引:0
|
作者
Bergmann, G. [1 ]
Graichen, F. [1 ]
Rohlmann, A. [1 ]
Heinlein, B. [1 ]
Bender, A. [1 ]
Gabel, U. [1 ]
Westerhoff, P. [1 ]
机构
[1] Charite Univ Med Berlin, Biomech Lab, Klin Orthopadie, Campus Benjamin Franklin, Hindenburgdamm 30, D-12203 Berlin, Germany
关键词
Joint implant; Load; Measurement; In vivo; Telemetry;
D O I
10.1007/s10039-007-1229-0
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
With instrumented implants it is possible to measure joint loads directly in the body, which is important if we are to improve the stability, wear properties and fixation technology. The data can also indicate what activities lead to particularly high loads and should be avoided in the immediate postoperative period, which can also be helpful to physiotherapists. The article explains the technical principles of the measurements and gives examples of designs of instrumented implants. Measurements so far recorded with the aid of such implants in hip, knee and shoulder joints, of internal fixation devices in the spinal column and of vertebral body prostheses are presented and the practical conclusions these results allow are discussed. In view of the huge body of data recorded in hip joints, most of the advice that can be given here relate to the hip.
引用
收藏
页码:77 / 83
页数:7
相关论文
共 50 条
  • [21] Clinical reliability of transdental implants.
    Niedermeier, W
    Mayer, B
    JOURNAL OF DENTAL RESEARCH, 2000, 79 : 168 - 168
  • [22] A radiographic study of iti implants.
    Kullman, L
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : 452 - 452
  • [23] Annealing behavior of ClusterCarbon™ implants.
    Sekar, Karuppanan
    Krull, Wade
    Chan, Jason
    McCoy, Steve
    Gelpey, Jeff
    16TH IEEE INTERNATIONAL CONFERENCE ON ADVANCED THERMAL PROCESSING OF SEMICONDUCTORS - RTP 2008, 2008, : 107 - +
  • [24] Retrospective review of fractured implants.
    Eckert, SE
    Cal, E
    JOURNAL OF DENTAL RESEARCH, 1998, 77 : 708 - 708
  • [25] Hydroxyapatite coating on titanium for dental implants.
    Andrade, MC
    Ogasawara, T
    JOURNAL OF DENTAL RESEARCH, 1998, 77 (05) : 1180 - 1180
  • [26] NANOTECHNOLOGY IN DENTAL IMPLANTS. A NARRATIVE REVIEW
    Harris, J. Johnisha
    Rajasekar, Arvina
    INTERNATIONAL JOURNAL OF MEDICAL DENTISTRY, 2022, 26 (03) : 393 - 397
  • [27] Comparative evaluation of dense hydroxyapatite implants and hydroxyapatite-coated implants.
    Ogiso, M
    Yamamura, M
    Kuo, PT
    Lee, RR
    Borgese, D
    Matsumoto, T
    JOURNAL OF DENTAL RESEARCH, 1996, 75 : 2808 - 2808
  • [28] Systems test environment for retina implants.
    Hornig, R
    Ritter, A
    Eckmiller, R
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S859 - S859
  • [29] Axial and nonaxial loading of oral implants.
    Barbier, L
    Schepers, E
    JOURNAL OF DENTAL RESEARCH, 1998, 77 (05) : 1211 - 1211
  • [30] A microbiological study of subjects with failing implants.
    Salonen, MAM
    Tervonen, T
    Asikainen, S
    Raustia, AM
    JOURNAL OF DENTAL RESEARCH, 1998, 77 : 661 - 661