摘要
Pulse transit time (PTT) measured as the time delay between invasive proximal and distal blood pressure (BP) or flow waveforms (invasive PTT [I-PTT]) tightly correlates with BP. PTT estimated as the time delay between non-invasive proximal and distal arterial waveforms could therefore permit cuff-less BP monitoring. A popular noninvasive PTT estimate for this application is the time delay between ECG and photoplethysmography (PPG) waveforms (pulse arrival time [PAT]). Another estimate is the time delay between proximal and distal PPG waveforms (PPG-PTT). PAT and PPG-PTT were assessed as markers of BP over a wide physiologic range using I-PTT as a reference. Waveforms for determining I-PTT, PAT, and PPG-PTT through central arteries were measured from swine during baseline conditions and infusions of various hemodynamic drugs. Diastolic, mean, and systolic BP varied widely in each subject (group average (mean +/- SE) standard deviation between 25 +/- 2 and 36 +/- 2 mmHg). I-PTT correlated well with all BP levels (group average R-2 values between 0.86 +/- 0.03 and 0.91 +/- 0.03). PPG-PTT also correlated well with all BP levels (group average R-2 values between 0.81 +/- 0.03 and 0.85 +/- 0.02), and its R-2 values were not significantly different from those of I-PTT. PAT correlated best with systolic BP (group average R-2 value of 0.70 +/- 0.04), but its R-2 values for all BP levels were significantly lower than those of I-PTT (P < 0.005) and PPG-PTT (P < 0.02). The pre-ejection period component of PAT was responsible for its inferior correlation with BP. In sum, PPG-PTT was not different from I-PTT and superior to the popular PAT as a marker of BP.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Continuous blood pressure measurement using the pulse transit time: Comparison to intra-arterial measurement
    Patzak, Andreas
    Mendoza, Yuri
    Gesche, Heiko
    Konermann, Martin
    BLOOD PRESSURE, 2015, 24 (04) : 217 - 221
  • [42] Continuous blood pressure measurement by using the pulse transit time: comparison to a cuff-based method
    Heiko Gesche
    Detlef Grosskurth
    Gert Küchler
    Andreas Patzak
    European Journal of Applied Physiology, 2012, 112 : 309 - 315
  • [43] Continuous blood pressure measurement by using the pulse transit time: comparison to a cuff-based method
    Gesche, Heiko
    Grosskurth, Detlef
    Kuechler, Gert
    Patzak, Andreas
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2012, 112 (01) : 309 - 315
  • [44] Continuous non-invasive blood pressure during continuous repositioning by pulse transit time
    Jeong, Hieyong
    Yoshimoto, Kayo
    Wang, Tianyi
    Ohno, Takafumi
    Yamada, Kenji
    Kido, Michiko
    Ohno, Yuko
    COGENT ENGINEERING, 2016, 3 (01):
  • [45] Estimation of systolic and diastolic pressure using the pulse transit time
    Ye, Soo-Young
    Kim, Gi-Ryon
    Jung, Dong-Keun
    Baik, Seong-Wan
    Jeon, Gye-Rok
    World Academy of Science, Engineering and Technology, 2010, 43 : 726 - 731
  • [46] Methods for Continuous Non-invasive Measurement of Blood Pressure: Pulse Transit Time a Review
    Kaur, Harleen
    Bhutto, Javed Khan
    Choudhary, Bhawani Shankar
    ASIAN JOURNAL OF PHARMACEUTICS, 2018, 12 (03) : S863 - S872
  • [47] Non-invasive blood pressure data acquisition employing pulse transit time detection
    Kerola, J
    Kontra, V
    Sepponen, R
    PROCEEDINGS OF THE 18TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 18, PTS 1-5, 1997, 18 : 1308 - 1309
  • [48] Pulse Wave Transit Time and Its Relationship with Systolic Blood Pressure
    Zakaria, N. A.
    Sharifmuddin, N. B.
    Ridzwan, W. M. F. Wan Mohd.
    Mahmood, N. H.
    6TH WORLD CONGRESS OF BIOMECHANICS (WCB 2010), PTS 1-3, 2010, 31 : 1354 - +
  • [49] An implantable optical blood pressure sensor based on pulse transit time
    Fiala, Jens
    Bingger, Philipp
    Ruh, Dominic
    Foerster, Katharina
    Heilmann, Claudia
    Beyersdorf, Friedhelm
    Zappe, Hans
    Seifert, Andreas
    BIOMEDICAL MICRODEVICES, 2013, 15 (01) : 73 - 81
  • [50] Photoplethysmography Derivatives and Pulse Transit Time in Overnight Blood Pressure Monitoring
    Shahrbabaki, Sobhan Salari
    Ahmed, Beena
    Penzel, Thomas
    Cvetkovic, Dean
    2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 2855 - 2858