WALL-CORRECTION AND ABSORBED-DOSE CONVERSION FACTORS FOR FRICKE DOSIMETRY - MONTE-CARLO CALCULATIONS AND MEASUREMENTS

被引:31
|
作者
MA, CM
ROGERS, DWO
SHORTT, KR
ROSS, CK
NAHUM, AE
BIELAJEW, AF
机构
[1] ROYAL MARSDEN HOSP,SUTTON,SURREY,ENGLAND
[2] NATL RES COUNCIL CANADA,INST NATL MEASUREMENT STAND,OTTAWA K1A 0R6,ONTARIO,CANADA
关键词
D O I
10.1118/1.597128
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
For megavoltage radiotherapy photon beams, EGS4 Monte Carlo calculations show, and experimental measurements confirm with an accuracy of 0.2%, that glass or quartz-walled vials used in Fricke dosimetry increase the dose in the Fricke solution. This is mainly caused by increased electron scattering from the glass which increases the dose to the Fricke solution. The dose perturbation is shown to vary from nothing in a Co-60 beam up to 2% in a 24-MV beam. For plastic vials of similar shapes, calculations demonstrate that the effect is in the opposite direction and even at high energies it is much less (0.2% to 0.5%).
引用
收藏
页码:283 / 292
页数:10
相关论文
共 41 条
  • [21] Monte Carlo calculations of radiation quality correction factors for radiochromic film dosimetry in surface and ophthalmic brachytherapy
    Aragno, D.
    Pacilio, M.
    Rauco, R.
    Pressello, M. C.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S266 - S267
  • [22] Monte Carlo calculations of correction factors for plane-parallel ionization chambers in clinical electron dosimetry
    Araki, Fujio
    MEDICAL PHYSICS, 2008, 35 (09) : 4033 - 4040
  • [24] A Thorough Validation of Electron Monte-Carlo Dose Calculation Algorithm and Generation of Correction Factors for Independent Monitor Units Hand Calculations in Clinic
    Skinner, A.
    Souri, S.
    Baker, J.
    Sudentas, E.
    Gill, G.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [25] Investigation of correction factors for non-reference conditions in ion chamber photon dosimetry with Monte-Carlo simulations
    Wulff, Joerg
    Heverhagen, Johannes T.
    Karle, Heiko
    Zink, Klemens
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2010, 20 (01): : 25 - 33
  • [26] Monte Carlo simulated correction factors for high dose rate brachytherapy postal dosimetry audit methodology
    Chelminski, Krzysztof
    Dimitriadis, Alexis
    Abdulrahim, Roua
    Kazantsev, Pavel
    Granizo-Roman, Evelyn
    Kalinowski, Jonathan
    Enger, Shirin Abbasi
    Azangwe, Godfrey
    Carrara, Mauro
    Swamidas, Jamema
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2024, 32
  • [27] Monte Carlo and experimental determination of correction factors for gamma knife perfexion small field dosimetry measurements
    Zoros, E.
    Moutsatsos, A.
    Pappas, E. P.
    Georgiou, E.
    Kollias, G.
    Karaiskos, P.
    Pantelis, E.
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (18): : 7532 - 7555
  • [28] Fluence to local skin absorbed dose and dose equivalent conversion coefficients for monoenergetic positrons using Monte-Carlo code MCNP6
    Bourgois, L.
    Antoni, R.
    APPLIED RADIATION AND ISOTOPES, 2016, 107 : 372 - 376
  • [29] Cherenkov dosimetry via directional Cherenkov-to-dose conversion factors: Monte Carlo protocol and experimental feasibility
    Zlateva, Yana
    Seuntjens, Jan
    El Naqa, Issam
    MEDICAL PHYSICS, 2017, 44 (08) : 4369 - 4370
  • [30] Absorbed dose conversion factors for therapeutic kilovoltage and megavoltage x-ray beams calculated by the Monte Carlo method
    Knight, RT
    MEDICAL PHYSICS, 1997, 24 (02) : 336 - 336