FALSE-POSITIVE DIAGNOSIS OF A PHEOCHROMOCYTOMA WITH I-123 METAIODOBENZYLGUANIDINE

被引:15
|
作者
BATHMANN, J
NEUMANN, HPH
SIGMUND, G
MOSER, E
机构
[1] UNIV HOSP FREIBURG,DEPT NUCL MED,FREIBURG,GERMANY
[2] UNIV HOSP FREIBURG,DEPT RADIOL,FREIBURG,GERMANY
[3] UNIV HOSP FREIBURG,DEPT NEPHROL,FREIBURG,GERMANY
关键词
D O I
10.1097/00003072-199403000-00012
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The rare case of a false-positive scintiscan with I-123 labelled metaiodobenzylguanidine (MIBG) in a patient with suspected pheochromocytoma is reported. Focal accumulation of the tracer in the upper right abdomen, primarily thought to represent a right-sided pheochromocytoma, was subsequently proven to be caused by an ampullary renal pelvis. In cases of unexplained MIBG accumulation the possibility of prolonged retention of the tracer, because of an abnormality of the renal pelvis, should be considered and excluded by ultrasound.
引用
收藏
页码:221 / 223
页数:3
相关论文
共 50 条
  • [31] Diagnosis of pheochromocytoma using [123I]-compared with [131I]-metaiodobenzylguanidine scintigraphy
    Furuta, N
    Kiyota, H
    Yoshigoe, F
    Hasegawa, N
    Ohishi, Y
    INTERNATIONAL JOURNAL OF UROLOGY, 1999, 6 (03) : 119 - 124
  • [32] I-123 METAIODOBENZYLGUANIDINE SCINTIGRAPHY OF ECTOPIC INTRACRANIAL RETINOBLASTOMA
    BOMANJI, J
    KINGSTON, JE
    HUNGERFORD, JL
    BRITTON, KE
    MEDICAL AND PEDIATRIC ONCOLOGY, 1989, 17 (01): : 66 - 68
  • [33] IMAGING OF CARCINOID-TUMORS WITH I-123 METAIODOBENZYLGUANIDINE
    BOMANJI, J
    LEVISON, DA
    ZUZARTE, J
    BRITTON, KE
    JOURNAL OF NUCLEAR MEDICINE, 1987, 28 (12) : 1907 - 1910
  • [34] Infected sebaceous cyst - A cause for false-positive total-body I-123 metastatic survey for thyroid cancer
    Turoglu, HT
    Naddaf, S
    Young, I
    AbdelDayem, HM
    CLINICAL NUCLEAR MEDICINE, 1996, 21 (11) : 887 - 887
  • [35] UPTAKE MECHANISMS OF I-123 METAIODOBENZYLGUANIDINE (METAIODOBENZYLGUANIDINE) IN ISOLATED RAT-HEART
    DEGRADO, TR
    ZALUTSKY, MR
    AFFLECK, DJ
    VAIDYANATHAN, G
    CIRCULATION, 1993, 88 (04) : 355 - 355
  • [36] QUANTITATIVE-ANALYSIS OF I-123 METAIODOBENZYLGUANIDINE (METAIODOBENZYLGUANIDINE) UPTAKE IN HYPERTROPHIC CARDIOMYOPATHY
    NAKAJIMA, K
    BUNKO, H
    TAKI, J
    SHIMIZU, M
    MURAMORI, A
    HISADA, K
    AMERICAN HEART JOURNAL, 1990, 119 (06) : 1329 - 1337
  • [37] FALSE-POSITIVE TEST FOR PHEOCHROMOCYTOMA WITH AN ADRENOLYTIC COMPOUND
    MEILMAN, E
    NEW ENGLAND JOURNAL OF MEDICINE, 1951, 245 (05): : 177 - 179
  • [38] BASIS OF FALSE-POSITIVE GLUCAGON TESTS FOR PHEOCHROMOCYTOMA
    KUCHEL, O
    HAMET, P
    BUU, NT
    LAROCHELLE, P
    CLINICAL PHARMACOLOGY & THERAPEUTICS, 1981, 29 (05) : 687 - 694
  • [39] I-123 METAIODOBENZYLGUANIDINE OR I-131 METAIODOBENZYLGUANIDINE FOR IMAGING OF NEUROBLASTOMA - A COMPARATIVE-STUDY
    SINON, B
    HOEFNAGEL, CA
    DEKRAKER, J
    VANSTEEG, G
    OLMOS, RAV
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1992, 19 (08): : 589 - 589
  • [40] PYRIDOSTIGMINE BROMIDE - A NEW FALSE-POSITIVE CAUSE IN THE BIOCHEMICAL-DIAGNOSIS OF PHEOCHROMOCYTOMA
    PASCUAL, CH
    SIMO, R
    MESA, J
    REVISTA CLINICA ESPANOLA, 1993, 192 (07): : 357 - 357