CAPILLARY FILTRATION COEFFICIENTS USING LASER DENSITOMETRY AND GRAVIMETRY IN ISOLATED DOG LUNGS

被引:14
|
作者
PARKER, JC
PRASAD, R
ALLISON, RA
WOJCHIECHOWSKI, WV
MARTIN, SL
机构
[1] Dept. of Physiology, College of Medicine, University of South Alabama, Mobile
关键词
PULMONARY EDEMA; VASCULAR PERMEABILITY; STARLING FORCES;
D O I
10.1152/jappl.1993.74.4.1981
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
We compared pulmonary capillary filtration coefficients (K(f,c)) using measurements of transcapillary filtration rates based on laser densitometry of perfusate hematocrit changes (J(v,l)) and gravimetric measurement of the rate of lobe weight gain (DELTAWt/DELTAt) after an increase in capillary pressure (Pc) in isolated autologous blood-perfused dog lungs. Although the lobe weight increased at a rate that decreased with time, the densitometric filtration rate was relatively constant over time. K(f,c) values were calculated in milliliters per minute per centimeter water per 100 g from filtration rates obtained by 1) extrapolation of the DELTAWt/DELTAt from 3 to 10 min back to time 0 [K(f,c(0))]; 2) use of the slope of the line fitted to the DELTAWt/DELTAt and J(v,l) values obtained after three stepwise increases in Pc [K(f,c(slope))], and 3) use of DELTAWt/DELTAt and J(v,l) values obtained 10, 20, and 30 min after either a constant 30-min or three 10-min stepwise increases in Pc [K(f,c(t))]. The mean K(f,c(0)) values ranged from 0.171 +/- 0.024 to 0.188 +/- 0.070 and were not significantly different between vascular pressure states. These K(f,c(0)) values were significantly higher than all gravimetric or densitometric K(f,c(t)) or K(f,c(slope)) values that ranged from 0.037 to 0.100. K(f,c(t)) values were not statistically different from each other by use of either method, but the gravimetric K(f,c(slope)) was significantly higher than the densitometric value. Therefore, extrapolated K(f,c(0)) probably overestimates endothelial barrier K(f,c) because of persistent vascular stress relaxation after a vascular pressure increase. Adjustment of tissue Starling forces may occur rapidly after an increase in filtration pressure.
引用
收藏
页码:1981 / 1987
页数:7
相关论文
共 38 条
  • [31] ENDOGENOUS NITRIC-OXIDE ATTENUATES PHORBOL ESTER-INDUCED INCREASES IN FILTRATION COEFFICIENT IN ISOLATED BLOOD-PERFUSED DOG LUNGS
    SPRAGUE, RS
    INOUE, KH
    STEPHENSON, AH
    WEINTRAUB, NL
    MCMURDO, L
    LONIGRO, AJ
    FASEB JOURNAL, 1995, 9 (03): : A130 - A130
  • [32] Effects of partial liquid ventilation with perfluorocarbons on pressure-flow relationships, vascular compliance, and filtration coefficients of isolated blood-perfused rabbit lungs
    Loer, SA
    Tarnow, J
    CRITICAL CARE MEDICINE, 1998, 26 (12) : 2037 - 2041
  • [33] THE EFFECTS OF GRADED ADMINISTRATION OF POSITIVE END EXPIRATORY PRESSURE ON THE FLUID FILTRATION-RATE IN ISOLATED RABBIT LUNGS, USING NORMAL LUNGS, HYDROSTATIC EDEMA LUNGS AND OLEIC-ACID INDUCED EDEMA
    ZABNER, J
    ANGELI, LS
    MARTINEZ, RR
    DELEON, RS
    INTENSIVE CARE MEDICINE, 1990, 16 (02) : 89 - 94
  • [34] PULMONARY CAPILLARY FILTRATION COEFFICIENTS (KF,C) ESTIMATED USING ZERO-TIME AND LATER RATES OF LUNG WEIGHT-GAIN
    PARKER, JC
    FASEB JOURNAL, 1993, 7 (04): : A898 - A898
  • [35] VARIATIONS IN CELLULAR ATTENUATION AND VESICLE NUMERICAL DENSITIES IN CAPILLARY ENDOTHELIUM AND TYPE-I EPITHELIUM OF ISOLATED, PERFUSED DOG LUNGS AFTER ACUTE SEVERE EDEMA FORMATION
    DEFOUW, DO
    CHINARD, FP
    MICROVASCULAR RESEARCH, 1983, 26 (01) : 15 - 26
  • [36] INCREASE IN CAPILLARY TRANSPORT OF C-14 UREA CAUSED BY INCREASING FLOW IN ISOLATED DOG LUNGS CORRELATES WITH VOLUMES FROM LUNG CO DIFFUSING-CAPACITY
    MAURER, CR
    LEVY, M
    POU, NA
    HARRIS, TR
    FEDERATION PROCEEDINGS, 1986, 45 (03) : 551 - 551
  • [37] MEASUREMENT OF LUNG WATER (VW) IN NORMAL AND EDEMATOUS ISOLATED DOG LUNGS USING INHALED (CO2)-O-15 AND INJECTED (H2O)-O-15
    SWINBURNE, AJ
    MACARTHUR, CGC
    RHODES, CG
    HEATHER, JD
    HUGHES, JMB
    HYDE, RW
    FEDERATION PROCEEDINGS, 1979, 38 (03) : 1264 - 1264
  • [38] Evaluation of Capillary Blood Gases in Medical Personnel Caring for Patients Isolated Due to SARS-CoV-2 in Intensive Care Units before and after Using Enhanced Filtration Masks: A Prospective Cohort Study
    Medrzycka-Dabrowska, Wioletta
    Slezak, Daniel
    Robakowska, Marlena
    Zuratynski, Przemyslaw
    Krzyzanowski, Kamil
    Malecka-Dubiela, Anna
    Dabrowski, Sebastian
    Zorena, Katarzyna
    Lewandowska, Katarzyna
    Ozga, Dorota
    Chmielarz, Karina
    Buca, Paulina
    Tomaszek, Lucyna
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (18)