SUBMICRON BIODEGRADABLE POLYMER MEMBRANE HEMOGLOBIN NANOCAPSULES AS POTENTIAL BLOOD SUBSTITUTES - A PRELIMINARY-REPORT

被引:38
|
作者
YU, WP
CHANG, TMS
机构
[1] Artificial Cells and Organs Research Centre, Faculty of Medicine, McGill University, Montreal,Quebec
来源
ARTIFICIAL CELLS BLOOD SUBSTITUTES AND IMMOBILIZATION BIOTECHNOLOGY | 1994年 / 22卷 / 03期
基金
英国医学研究理事会;
关键词
D O I
10.3109/10731199409117926
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
We used biodegradable polymers like polylactic acid, poly-isobutylcyanoacrylate and others to prepare nanocapsules containing hemoglobin. We prepared the optimal mean diameters of between 0.08 to 0.12 micron (80 - 120 nm). They are spherical and homogeneous. The membrane thickness is 0.005-0.015 micron (5-15nm). With different formulation, the hemoglobin contents in the particles may be varied from 30 - 45 %. Phospholipid is not required in bovine hemoglobin. It is required for human hemoglobin in order to retain cofactors required for optimal P50. The P50 of the biodegradable polymer membrane containing bovine hemoglobin was between 27 - 29 mmHg. This is the same P50 as bovine hemoglobin used in the preparation. Thus the procedure of preparation did not damage hemoglobin.
引用
收藏
页码:889 / 893
页数:5
相关论文
共 50 条
  • [41] BRONCHOPULMONARY ANASTOMIC BLOOD-FLOW IN CONSCIOUS HUMANS - A PRELIMINARY-REPORT
    PINSKY, MR
    KORMOS, RL
    GRIFFITH, BP
    BOROVETZ, HS
    FEDERATION PROCEEDINGS, 1987, 46 (03) : 515 - 515
  • [42] EFFECT OF CHRONIC SMOKING ON DIGITAL BLOOD-FLOW - A PRELIMINARY-REPORT
    SANTOSH, V
    BHATNAGAR, BNS
    GAUTAM, A
    REDDY, LP
    RAI, UC
    VASCULAR SURGERY, 1994, 28 (02): : 123 - 127
  • [43] DISRUPTION OF BLOOD-RETINAL BARRIER IN OCULAR HYPOTONY - PRELIMINARY-REPORT
    TSO, MOM
    SHIH, CY
    EXPERIMENTAL EYE RESEARCH, 1976, 23 (02) : 209 - 216
  • [44] RELATIONSHIP BETWEEN BLOOD MEPERIDINE CONCENTRATIONS AND ANALGESIC RESPONSE - A PRELIMINARY-REPORT
    AUSTIN, KL
    STAPLETON, JV
    MATHER, LE
    ANESTHESIOLOGY, 1980, 53 (06) : 460 - 466
  • [45] REGIONAL CEREBRAL BLOOD-FLOW IN PATIENTS WITH SCHIZOPHRENIA - A PRELIMINARY-REPORT
    KAWASAKI, Y
    SUZUKI, M
    MAEDA, Y
    URATA, K
    YAMAGUCHI, N
    MATSUDA, H
    HISADA, K
    SUZUKI, M
    TAKASHIMA, T
    EUROPEAN ARCHIVES OF PSYCHIATRY AND CLINICAL NEUROSCIENCE, 1992, 241 (04) : 195 - 200
  • [46] THE BLOOD-CIRCULATION IN THE NORMAL SAPHENOUS SYSTEM IN MAN - (PRELIMINARY-REPORT)
    BJORDAL, RI
    VASA-JOURNAL OF VASCULAR DISEASES, 1983, 12 (03): : 302 - 302
  • [47] SPLENIC BLOOD-FLOW MEASUREMENTS BY DOPPLER ULTRASOUND - A PRELIMINARY-REPORT
    MANOHARAN, A
    GILL, RW
    GRIFFITHS, KA
    CARDIOVASCULAR RESEARCH, 1987, 21 (10) : 779 - 782
  • [48] ABNORMAL-BLOOD RHEOLOGY IN RETINAL VEIN OCCLUSION - A PRELIMINARY-REPORT
    PEDUZZI, M
    DEBBIA, A
    GUERRIERI, F
    BOLZANI, R
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1986, 224 (01) : 83 - 85
  • [49] ELEVATED PENILE BLOOD PRESSURES IN PATIENTS WITH PREMATURE EJACULATION - PRELIMINARY-REPORT
    ZORGNIOTTI, AW
    UROLOGY, 1979, 13 (02) : 185 - 185
  • [50] PRELIMINARY-REPORT ON INVESTIGATION OF TESTOSTERONE ENANTHATE (TE) AS A POTENTIAL MALE CONTRACEPTIVE
    STEINBERGER, E
    CERVANTES, A
    SMITH, KD
    FERTILITY AND STERILITY, 1976, 27 (02) : 216 - 216