Partial Discharge Detection of High Voltage Switchgear Using a Ultra High Frequency Sensor

被引:5
|
作者
Shin, Jong-Yeol [1 ]
Lee, Young-Sang [2 ]
Hong, Jin-Woong [2 ]
机构
[1] Sahmyook Univ, Dept Car Mechatron, Seoul 139742, South Korea
[2] Kwangwoon Univ, Dept Elect Engn, Seoul 139701, South Korea
关键词
Ultra high frequency; High voltage switchgear; Gas insulated switchgear; Partial discharge; Insulation; Diagnosis techniques;
D O I
10.4313/TEEM.2013.14.4.211
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Partial discharge diagnosis techniques using ultra high frequencies do not affect load movement, because there is no interruption of power. Consequently, these techniques are popular among the prevention diagnosis methods. For the first time, this measurement technique has been applied to the GIS, and has been tested by applying an extra high voltage switchboard. This particular technique makes it easy to measure in the live state, and is not affected by the noise generated by analyzing the causes of faults ? thereby making risk analysis possible. It is reported that the analysis data and the evaluation of the risk level are improved, especially for poor location, and that the measurement of Ultra high frequency (UHF) partial discharge of the real live wire in industrial switchgear is spectacular. Partial discharge diagnosis techniques by using the Ultra High Frequency sensor have been recently highlighted, and it is verified by applying them to the GIS. This has become one of the new and various power equipment techniques. Diagnosis using a UHF sensor is easy to measure, and waveform analysis is already standardized, due to numerous past case experiments. This technique is currently active in research and development, and commercialization is becoming a reality. Another aspect of this technique is that it can determine the occurrences and types of partial discharge, by the application diagnosis for live wire of ultra high voltage switchgear. Measured data by using the UHF partial discharge techniques for ultra high voltage switchgear was obtained from 200 places in Gumi, Yeosu, Taiwan and China's semiconductor plants, and also the partial discharge signals at 15 other places were found. It was confirmed that the partial discharge signal was destroyed by improving the work of junction bolt tightening check, and the cable head reinforcement insulation at 8 places with a possibility for preventing the interruption of service. Also, it was confirmed that the UHF partial discharge measurement techniques are also a prevention diagnosis method in actual industrial sites. The measured field data and the usage of the research for risk assessment techniques of the live wire status of power equipment make a valuable database for future improvements.
引用
收藏
页码:211 / 215
页数:5
相关论文
共 50 条
  • [41] Design of UHF Antenna Sensor for Partial Discharge Detection in High Voltage S ubstation
    Mukhtar, Sharulnizam Mohd
    Isa, Muzamir
    Al-Hadi, Azremi Abdullah
    MALAYSIAN TECHNICAL UNIVERSITIES CONFERENCE ON ENGINEERING AND TECHNOLOGY 2017 (MUCET 2017), 2018, 318
  • [42] A fiber optic sensor for the detection of Partial Discharge within the High Voltage power transformer
    Sarkar, B.
    Koley, C.
    Roy, N. K.
    Kumbhakar, P.
    FOUNDATIONS AND FRONTIERS IN COMPUTER, COMMUNICATION AND ELECTRICAL ENGINEERING, 2016, : 177 - 181
  • [43] A Communication Interference Suppression Method for Ultra High-Frequency Partial Discharge Detection
    Wang Caixiong
    Zhang Liangen
    Hua Zhenghao
    Tang Zhiguo
    Chang Wenzhi
    Li Chengrong
    PROCEEDINGS OF 2012 IEEE INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (IEEE CMD 2012), 2012, : 740 - 743
  • [44] Comprehensive detection of partial discharge in switchgear using TEV
    Ren, Ming
    Peng, Hua-Dong
    Chen, Xiao-Qing
    Dong, Ming
    Gaodianya Jishu/High Voltage Engineering, 2010, 36 (10): : 2460 - 2466
  • [45] Best Antenna Arrangements for Partial Discharge Detection in Medium Voltage Switchgear
    Permal, Navinesshani
    Amir, Mohd Dzaki Mohd
    Chakrabarty, Chandan Kumar
    Ramasamy, Agileswari K.
    PROCEEDINGS OF THE 2017 IEEE 15TH STUDENT CONFERENCE ON RESEARCH AND DEVELOPMENT (SCORED), 2017, : 434 - 439
  • [46] Bioinspired Ultrahigh Frequency Antenna for Partial Discharge Detection in High-Voltage Equipment
    Ardila-Rey, Jorge Alfredo
    Figueroa Karmelic, Daniel
    Pizarro, Francisco
    Govindarajan, Suganya
    Albuquerque de Castro, Bruno
    Schurch, Roger
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73
  • [47] An Intelligent Sensor for the Ultra-High-Frequency Partial Discharge Online Monitoring of Power Transformers
    Li, Jian
    Li, Xudong
    Du, Lin
    Cao, Min
    Qian, Guochao
    ENERGIES, 2016, 9 (05)
  • [48] Research on Partial Discharge Detection and Evaluation Method for High Voltage Switchgear Based on AHP-Fuzzy Comprehensive Evaluation
    Li, Linze
    Wang, Caibao
    Yang, Man
    2024 7TH ASIA CONFERENCE ON ENERGY AND ELECTRICAL ENGINEERING, ACEEE 2024, 2024, : 144 - 149
  • [49] Partial Discharge Measurement in the Ultra High Frequency (UHF) Range
    Tenbohlen, S.
    Denissov, D.
    Hoek, S. M.
    Markalous, S. M.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2008, 15 (06) : 1544 - 1552
  • [50] Partial Discharge Measurement to Predict the Lifetime of High Frequency High Voltage Transformers
    Guastavino, F.
    Della Giovanna, L.
    Galbiati, S.
    Massa, B.
    Torello, E.
    2023 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, CEIDP, 2023,