High-resolution clustered pinhole 131Iodine SPECT imaging in mice

被引:17
|
作者
van der Have, Frans [1 ,2 ,3 ]
Ivashchenko, Oleksandra [1 ,2 ,3 ]
Goorden, Marlies C. [1 ]
Ramakers, Ruud M. [1 ,2 ,3 ]
Beekman, Freek J. [1 ,2 ,3 ]
机构
[1] Delft Univ Technol, Sect Radiat Detect & Med Imaging, Mekelweg 15, NL-2629 JB Delft, Netherlands
[2] MIlabs BV, Heidelberglaan 100 STR 4-105, NL-3584 CX Utrecht, Netherlands
[3] Univ Med Ctr Utrecht, Brain Ctr Rudolf Magnus, Dept Translat Neurosci, NL-3584 CG Utrecht, Netherlands
关键词
SPECT; Molecular imaging; Radioiodine; Radioimmunotherapy; SODIUM-IODIDE SYMPORTER; EMISSION COMPUTED-TOMOGRAPHY; I-131; TOSITUMOMAB; ANTIBODY THERAPY; HODGKIN-LYMPHOMA; CELL LYMPHOMA; IN-VIVO; RADIOIMMUNOTHERAPY; ISOTOPES; PET;
D O I
10.1016/j.nucmedbio.2016.05.015
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: High-resolution pre-clinical I-131 SPECT can facilitate development of new radioiodine therapies for cancer. To this end, it is important to limit resolution-degrading effects of pinhole edge penetration by the high-energy gamma-photons of iodine. Here we introduce, optimize and validate I-131 SPECT performed with a dedicated high-energy clustered multi-pinhole collimator. Methods: A SPECT-CT system (VECTor/CT) with stationary gamma-detectors was equipped with a tungsten collimator with clustered pinholes. Images were reconstructed with pixel-based OSEM, using a dedicated I-131 system matrix that models the distance- and energy-dependent resolution and sensitivity of each pinhole, as well as the intrinsic detector blurring and variable depth of interaction in the detector. The system performance was characterized with phantoms and in vivo static and dynamic I-131-NaI scans of mice. Results: Reconstructed image resolution reached 0.6 mm, while quantitative accuracy measured with a I-131 filled syringe reaches an accuracy of +3.6 +/- 3.5% of the gold standard value. In vivo mice scans illustrated a clear shape of the thyroid and biodistribution of I-131 within the animal. Pharmacokinetics of I-131 was assessed with 15-s time frames from the sequence of dynamic images and time-activity curves of I-131-NaI. Conclusions: High-resolution quantitative and fast dynamic I-131 SPECT in mice is possible by means of a high-energy collimator and optimized system modeling. This enables analysis of I-131 uptake even within small organs in mice, which can be highly valuable for development and optimization of targeted cancer therapies. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:506 / 511
页数:6
相关论文
共 50 条
  • [31] High-resolution MR imaging in mice
    Frank Wiesmann
    Jan Ruff
    Axel Haase
    Magnetic Resonance Materials in Physics, Biology and Medicine, 1998, 6 : 186 - 188
  • [32] High-resolution MR imaging in mice
    Wiesmann, Frank
    Ruff, Jan
    Haase, Axel
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 1998, 6 (2-3) : 186 - 188
  • [33] Performance evaluation of A-SPECT: A high resolution desktop pinhole SPECT system for imaging small animals
    McElroy, DP
    MacDonald, LR
    Beekman, FJ
    Wang, YC
    Patt, BE
    Iwanczyk, JS
    Tsui, BMW
    Hoffman, EJ
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (05) : 2139 - 2147
  • [34] Evaluation of a pinhole collimator for I-131 SPECT head imaging
    Gilland, DR
    Johnson, EL
    Turkington, TG
    Coleman, RE
    Jaszczak, RJ
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (04) : 2230 - 2238
  • [35] THE USE OF A CONVERGING COLLIMATOR FOR HIGH-RESOLUTION SPECT IMAGING
    WEBB, S
    BRODERICK, M
    FLOWER, MA
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1984, 9 (07): : A83 - A83
  • [36] High-resolution SPECT for small-animal imaging
    QI Yu-Jin (Shanghai Institute of Applied Physics
    NuclearScienceandTechniques, 2006, (03) : 164 - 169
  • [37] HIGH-RESOLUTION SPECT IMAGING OF THE SPINE IN CHILDREN AND ADOLESCENTS
    GELFAND, MJ
    ELGAZZAR, AH
    MARTICH, V
    GOLSCH, G
    JOURNAL OF NUCLEAR MEDICINE, 1993, 34 (05) : P52 - P52
  • [38] Myocardial Perfusion Imaging with Ultra-high Resolution SPECT/CT System in Rats using Multiple Pinhole Collimator: Comparison with High-resolution Autoradiography
    Wakabayashi, Hiroshi
    Taki, Junichi
    Inaki, Anri
    Hiromasa, Tomo
    Kunita, Yuji
    Akatani, Norihito
    Shiba, Kazuhiro
    Kinuya, Seigo
    JOURNAL OF NUCLEAR MEDICINE, 2017, 58
  • [39] HIGH-RESOLUTION 4-HEAD PINHOLE SPECT SYSTEM FOR SMALL ANIMAL STUDIES
    ISHIZU, K
    MUKAI, T
    YONEKURA, Y
    FUJITA, T
    MAGATA, Y
    NISHIZAWA, S
    TAMAKI, N
    SHIBASAKI, H
    KONISHI, J
    JOURNAL OF NUCLEAR MEDICINE, 1994, 35 (05) : P196 - P196
  • [40] Myocardial imaging of mice using pinhole SPECT.
    Wu, MC
    Tang, HR
    Wong, KH
    Gao, DW
    Ido, A
    Hasegawa, BH
    Dae, MW
    JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (05) : 20P - 20P