摘要
The successful development of the Plasma Opening Switch (POS) for inductive storage applications has been largely confined to negative polarity operation. Some models of POS behavior suggest that this is because in a positive polarity coaxial configuration, the weaker magnetic field at the cathode position retards the switch opening process. This article describes experiments in which both conductor radii in the POS region were significantly reduced. Anode- and cathode-side current monitors indicate that voltages greater than open-circuit are generated at the POS position, but there is a significant amount of electron flow out of the POS, depending upon load impedance. Flow impedance analysis indicates that a relatively small gap appears in the POS plasma after switch opening. Switch performance is also compared between flashboard and carbon gun plasma sources, with the latter operated both in positive and negative polarity. © 1995 American Institute of Physics.
引用
收藏
页码:2244 / 2253
页数:10
相关论文
共 50 条
  • [21] Laser oscillation using an inductive energy storage pulsed-power generator with plasma opening switch
    Kamatani, M
    Ihara, S
    Satoh, S
    Yamabe, C
    VACUUM, 2000, 59 (01) : 349 - 357
  • [22] Influence of a Circuit Parameter for Plasma Water Treatment by an Inductive Energy Storage Circuit Using Semiconductor Opening Switch
    Sugai, Taichi
    Liu, Wei
    Tokuchi, Akira
    Jiang, Weihua
    Minamitani, Yasushi
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2013, 41 (04) : 967 - 974
  • [23] DISCHARGE PUMPING OF NE-XE-HCL AND N-2 LASERS USING A PLASMA EROSION OPENING SWITCH
    MESIATS, GA
    PANCHENKO, AN
    TARASENKO, VF
    DOKLADY AKADEMII NAUK SSSR, 1989, 307 (04): : 869 - 872
  • [24] Comparative study of bacteria sterilization by cold plasma produced by DC generator with positive and negative polarity using atmospheric pressure
    Djemaa, Benzerga
    Benmimoun, Youcef
    Bekkara, Mohammed Fethi
    Kellal, Sid-Ahmed
    Fellah, Benzerga
    PRZEGLAD ELEKTROTECHNICZNY, 2020, 96 (12): : 58 - 62
  • [25] COMPUTER SIMULATION OF HIGH-POWER ION BEAM GENERATION USING THE PLASMA EROSION OPENING SWITCH AND MICROSECOND STORE SYSTEMS.
    Bystritskii, V.M.
    Krasik, Ya E.
    Sinebryukhov, A.A.
    IEEE Transactions on Plasma Science, 1987, PS-15 (06) : 678 - 685
  • [26] Improvement of Plasma Gun Performance using Comprehensive Fluid Element Modeling: Part I
    Felix A. Muggli
    Ronald J. Molz
    Richard McCullough
    Dave Hawley
    Journal of Thermal Spray Technology, 2007, 16 : 677 - 683
  • [27] Improvement of plasma gun performance using comprehensive fluid element modeling: Part I
    Muggli, Felix A.
    Molz, Ronald J.
    McCullough, Richard
    Hawley, Dave
    JOURNAL OF THERMAL SPRAY TECHNOLOGY, 2007, 16 (5-6) : 677 - 683
  • [28] COMPUTER-SIMULATION OF HIGH-POWER ION-BEAM GENERATION USING THE PLASMA EROSION OPENING SWITCH AND MICROSECOND STORE SYSTEMS
    BYSTRITSKII, VM
    KRASIK, YE
    SINEBRYUKHOV, AA
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 1987, 15 (06) : 678 - 685
  • [29] Simultaneous determination of carisoprodol and aspirin in human plasma using liquid chromatography-tandem mass spectrometry in polarity switch mode: application to a human pharmacokinetic study
    Sreenivasulu, Vudagandla
    Ramesh, Mullangi
    Kumar, Inamadugu Jaswanth
    Babu, Ravi Vasu
    Pilli, Nageswara Rao
    Krishnaiah, Abburi
    BIOMEDICAL CHROMATOGRAPHY, 2013, 27 (02) : 179 - 185
  • [30] Self-matching plasma sources using 2.45 GHz solid-state generators: microwave design and operating performance
    Latrasse, Louis
    Radoiu, Marilena
    Nelis, Thomas
    Antonin, Olivier
    JOURNAL OF MICROWAVE POWER AND ELECTROMAGNETIC ENERGY, 2017, 51 (04) : 237 - 258