SUSTAINED EFFECTIVENESS OF AN ATRIAL ANTITACHYCARDIA PACEMAKER DURING FOLLOW-UP

被引:4
|
作者
SHANDLING, AH
LI, CK
THOMAS, L
机构
[1] UNIV CALIF IRVINE,DEPT CARDIOL,IRVINE,CA 92717
[2] LONG BEACH MEM MED CTR,DEPT CARDIOL,LONG BEACH,CA
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1990年 / 13卷 / 07期
关键词
antifachycardia pacemaker; atrial arrhythmias; nonpharmacological treatment;
D O I
10.1111/j.1540-8159.1990.tb02118.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Atrial antitachycardia pacemakers are indicated for medically refractory atrial rachyarrhyth‐mias. To confirm long‐term device effectiveness, we studied diagnostic data obtained in 17 patients with atrially‐placed Intermedic “Iniertach” pacemakers. The unit has programmable primary (P mod) and secondary (S mod) antitachycardia response protocols. Success of the P mod was defined as a P mod response first with no subsequent S mod response. Follow‐up was for 595 days (±302 days). The P mod was utilized first 88.2 ± 102 times per patient interrogation with subsequent S mod use 21.1 ± 53 times (P < 0.0001). Results were also significant when P mod was compared to S mod in the first versus the last half of follow‐up (both P < 0.0001). These results suggest that the programmed P mod of the atrial “Intertach” tachycardia reversion pacemaker has sustained effectiveness in the treatment of medically refractory atrial tachyarrhythmias. Copyright © 1990, Wiley Blackwell. All rights reserved
引用
收藏
页码:833 / 838
页数:6
相关论文
共 50 条
  • [41] Follow-up of Patients with Sustained Virologic Response
    Semmler G.
    Mandorfer M.
    Journal für Gastroenterologische und Hepatologische Erkrankungen, 2020, 18 (4) : 110 - 117
  • [42] FOLLOW-UP OF A COHORT OF PACEMAKER PATIENTS 9 YEARS ON
    RIDDELL, F
    WHITLOCK, RML
    SMITH, W
    NEW ZEALAND MEDICAL JOURNAL, 1991, 104 (914) : 265 - 265
  • [43] Reassessment of Risk for Stroke During Follow-up of Patients With Atrial Fibrillation
    Chao, Tze-Fan
    Chiang, Chern-En
    Chen, Tzeng-Ji
    Lip, Gregory Y. H.
    Chen, Shih-Ann
    ANNALS OF INTERNAL MEDICINE, 2019, 170 (09) : 663 - +
  • [44] Feasibility of a telemedicine framework for collaborative pacemaker follow-up
    Kollmann, Alexander
    Hayn, Dieter
    Garcia, Jose
    Trigo, Jesus Daniel
    Kastner, Peter
    Rotman, Brigitte
    Tscheliessnigg, Karlheinz
    Schreier, Guenter
    JOURNAL OF TELEMEDICINE AND TELECARE, 2007, 13 (07) : 341 - 347
  • [45] ACCURACY AND CLINICAL UTILITY OF TRANSTELEPHONIC PACEMAKER FOLLOW-UP
    GESSMAN, LJ
    VIELBIG, RE
    WASPE, LE
    MOSS, L
    DAMM, D
    SUNDEEN, F
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1995, 18 (05): : 1032 - 1036
  • [46] IMPROVED PACEMAKER FOLLOW-UP MANAGEMENT WITH COMPUTERIZED SYSTEMS
    MOREIRA, LFP
    VELLOSO, VWB
    OLIVEIRA, Z
    COSTA, R
    STOLF, NAG
    JATENE, AD
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1987, 10 (03): : 720 - 720
  • [47] Holter EKG for follow-up of pacemaker patients - a necessity?
    Nagel, B.
    Gamillscheg, A.
    Anelli-Monti, M.
    Beitzke, A.
    CLINICAL RESEARCH IN CARDIOLOGY, 2007, 96 (09) : 664 - 664
  • [48] HEMODYNAMIC MONITORING, CARDIAC OUTPUT, ON PACEMAKER FOLLOW-UP
    Gorini, D.
    Spitali, G.
    Tampieri, E.
    Placci, A.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2009, 20 : S61 - S61
  • [49] DEMAND TYPE PACEMAKER AND TELETRANSMITTER FOLLOW-UP SYSTEM
    STARR, A
    DABOLT, L
    DOBBS, JL
    PIERIE, W
    CIRCULATION, 1972, 46 (04) : 109 - &
  • [50] A SIMPLIFIED PROGRAM FOR COMPUTER FOLLOW-UP OF PACEMAKER PATIENTS
    BOSCH, R
    ANTUNEZ, F
    BELAZA, J
    DEHEBRON, RSV
    CORAZON, HS
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1985, 8 (03): : A20 - A20