Performance modeling of industrial gas turbines with inlet air filtration system

被引:13
|
作者
Effiom, Samuel O. [1 ]
Abam, Fidelis I. [2 ]
Ohunakin, Olayinka S. [3 ]
机构
[1] Cross River Univ Technol, Dept Mech Engn, Calabar, Nigeria
[2] Michael Okpara Univ Agr, Dept Mech Engn, Umudike, Umuhia, Nigeria
[3] Covenant Univ Ota, Dept Mech Engn, Ota, Ogun State, Nigeria
关键词
Filters; Contaminants; Pressure drop; Gas turbine; Turbomatch;
D O I
10.1016/j.csite.2015.03.008
中图分类号
O414.1 [热力学];
学科分类号
摘要
The effect of inlet air filtration on the performance of two industrial gas turbines (GT) is presented. Two GTs were modeled similar to GE LM2500+ and Alstom GT13 E2-2012, using TURBOMATCH and chosen to operate at environmental conditions of Usan offshore oilfield and Maiduguri dessert in Nigeria. The inlet pressure recovered (P-recov) from the selected filters used in Usan offshore, and Maiduguri ranged between 98.36 <= P-recov <= 99.51 % and 98.67 <= P-recov <= 99.56% respectively. At reduced inlet P-recov 98.36% (1.66 kPa) and, at a temperature above 15 degrees C (ISA), a reduction of 16.9%, and 7.3% of power output and efficiency was obtained using GT13 E2-2012, while a decrease of 14.8% arid 4.7% exist for power output and efficiency with GE LM2500+ . In addition, a reduction in mass flow rate of air arid fuel under the same condition was between 4.3 <= m(air) <= 10.6% and 10.4 <= m(fuel) <= 11.5% for GT13 E2-2012 arid GE LM2500+, correspondingly. However, the GE LM2500+ was more predisposed to intake pressure drops since it functioned at a higher overall pressure ratio. The results obtained were found worthwhile arid could be the basis for filter selection arid efficient compressor housing design in the locations concerned. (C) 2015 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:160 / 167
页数:8
相关论文
共 50 条