ENZYME ELECTRODES WITH GLUCOSE-OXIDASE IMMOBILIZED ON STOBER GLASS-BEADS

被引:14
|
作者
YANG, QL
ATANASOV, P
WILKINS, E
HUGHES, RC
机构
[1] UNIV NEW MEXICO,DEPT CHEM & NUCL ENGN,ALBUQUERQUE,NM 87131
[2] SANDIA NATL LABS,ALBUQUERQUE,NM 87185
关键词
SOL-GEL MATRIX; STOBER GLASS BEADS; GLUCOSE ENZYME ELECTRODE;
D O I
10.1080/00032719508004027
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study we report the development and experimental evaluation of a miniature Stober glass-coated enzyme electrode for glucose biosensor applications. The enzyme - glucose oxidase - is chemically immobilized onto the surface of the Stober glass beads after a silanization procedure. The sensors were fabricated using grass beads of different radii ranging from 20 nm to 100 nm. The overall thickness of the glass coating was about 1.4 mu m in all cases. Initial calibration curves of the electrodes show an increase in the response value with decrease in the bead radius. Life-time evaluation tests, however, demonstrate a different behavior of the electrodes. At the end of a 50 day test, the electrode with bead radius of 70 nm remained most stable. The response of this electrode was stable over this period of time and no apparent decrease in its sensitivity was observed. This study suggests that there may be a relation between the immobilized enzyme stability and the porosity of the glass-bead layer. Preliminary tests in undiluted blood plasma suggest that electrodes can be used for glucose measurements in body fluids.
引用
收藏
页码:2439 / 2457
页数:19
相关论文
共 50 条
  • [31] AMPEROMETRIC ENZYME ELECTRODE FOR AEROBIC GLUCOSE MONITORING PREPARED BY GLUCOSE-OXIDASE IMMOBILIZED IN POLY(VINYLFERROCENIUM)
    GULCE, H
    OZYORUK, H
    CELEBI, SS
    YILDIZ, A
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1995, 394 (1-2): : 63 - 70
  • [32] AN ENZYME ELECTRODE FOR GLUCOSE CONSISTING OF GLUCOSE-OXIDASE IMMOBILIZED AT A BENZOQUINONE-MODIFIED CARBON ELECTRODE
    HU, J
    TURNER, APF
    ANALYTICAL LETTERS, 1991, 24 (01) : 15 - 24
  • [33] PROPERTIES OF GLUCOSE-OXIDASE IMMOBILIZED IN GEL OF POLYVINYLALCOHOL
    KOZHUKHAROVA, A
    KIROVA, N
    POPOVA, Y
    BATSALOVA, K
    KUNCHEV, K
    BIOTECHNOLOGY AND BIOENGINEERING, 1988, 32 (02) : 245 - 248
  • [34] REACTIVITY AND STABILITY IMPROVEMENT OF IMMOBILIZED GLUCOSE-OXIDASE
    LI, LX
    CHEN, CZ
    YU, YT
    BIOMATERIALS ARTIFICIAL CELLS AND ARTIFICIAL ORGANS, 1989, 17 (02): : 183 - 188
  • [35] GLUCOSE-OXIDASE ELECTRODES - EFFECT OF HYDROGEN-PEROXIDE ON ENZYME-ACTIVITY
    VONWOEDTKE, T
    FISCHER, U
    ABEL, P
    BIOSENSORS & BIOELECTRONICS, 1994, 9 (01): : 65 - 71
  • [36] THE CHARACTERIZATION OF LIPOSOMAL GLUCOSE-OXIDASE ELECTRODES FOR THE MEASUREMENT OF GLUCOSE
    TAYLOR, MA
    JONES, MN
    VADGAMA, PM
    HIGSON, SPJ
    BIOSENSORS & BIOELECTRONICS, 1995, 10 (3-4): : 251 - 260
  • [37] BINDING OF LACTOBACILLUS-REUTERI TO FIBRONECTIN IMMOBILIZED ON GLASS-BEADS
    LINDGREN, SE
    SWAISGOOD, HE
    JANOLINO, VG
    AXELSSON, LT
    RICHTER, CS
    MACKENZIE, JM
    DOBROGOSZ, WJ
    ZENTRALBLATT FUR BAKTERIOLOGIE-INTERNATIONAL JOURNAL OF MEDICAL MICROBIOLOGY VIROLOGY PARASITOLOGY AND INFECTIOUS DISEASES, 1992, 277 (04): : 519 - 528
  • [38] COATED GLASS-BEADS IN ENZYME LINKED IMMUNOSORBENT ASSAYS
    POLSON, A
    VANHEERDEN, D
    VANDERMERWE, KJ
    IMMUNOLOGICAL INVESTIGATIONS, 1985, 14 (03) : 223 - 231
  • [39] GLUCOSE SENSITIVITY OF THIOL MODIFIED GOLD ELECTRODES HAVING IMMOBILIZED GLUCOSE-OXIDASE AND 2-AMINOETHYLFERROCENE
    KAJIYA, Y
    OKAMOTO, T
    YONEYAMA, H
    CHEMISTRY LETTERS, 1993, (12) : 2107 - 2110
  • [40] KINETIC-STUDIES ON THE OXIDATION OF GLUCOSE BY IMMOBILIZED GLUCOSE-OXIDASE
    TSUKAMOTO, T
    NOMURA, H
    MORITA, S
    OKADA, J
    CHEMICAL & PHARMACEUTICAL BULLETIN, 1983, 31 (10) : 3377 - 3384