摘要
The authors identify eight areas of potential safety concern during clinical magnetic resonance (MR) imaging. These include (a) biologic effects of the static magnetic field; (b) ferromagnetic attractive 'projectile' effects of the static magnetic field; (c) potential effects of the relatively slowly time-varying magnetic field gradients; (d) effects of the rapidly varying radio-frequency (RF) magnetic fields, including RF power deposition concerns; (e) auditory considerations from noise caused by the rapidly pulsed magnetic field gradients; (f) safety considerations concerning superconductive systems, including quenches, use of cryogens, and cryogen storage and handling; (g) psychological effects, such as claustrophobia and anxiety induced because of the examination; and (h) possible effects of the intravenous use of the MR contrast agent gadopentetate dimeglumine. The concerns in each of these categories are elaborated upon, and the available data are presented to clarify their status.
引用
收藏
页码:593 / 606
页数:14
相关论文
共 50 条
  • [21] MR Imaging Safety Considerations of Gadolinium-Based Contrast Agents Gadolinium Retention and Nephrogenic Systemic Fibrosis
    McDonald, Jennifer S.
    McDonald, Robert J.
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2020, 28 (04) : 497 - +
  • [22] Metallic stents: Evaluation of MR imaging safety
    Shellock, FG
    Shellock, VJ
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 173 (03) : 543 - 547
  • [23] FIREARM SAFETY IN THE MR-IMAGING ENVIRONMENT
    KANAL, E
    SHAIBANI, A
    RADIOLOGY, 1994, 193 (03) : 875 - 876
  • [24] Sedation in MR imaging: What price safety?
    Finn, JP
    RADIOLOGY, 2000, 216 (03) : 633 - 634
  • [25] Safety Resources and Processes in MR Imaging Departments
    Beam, Asher Street
    Celestine, Ikia
    Ketchum, James M.
    Phillips, Layna
    Wilson, Audrey
    Patrick, Tyler
    Scoles, Chris
    Gray, Zack
    RADIOLOGIC TECHNOLOGY, 2019, 90 (03) : 225 - 236
  • [26] MR Imaging Safety Events Analysis and Improvement
    Watson, Robert E., Jr.
    Tesfaldet, Mussie
    Warren, Julee
    Hoff, Michael N.
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2020, 28 (04) : 593 - +
  • [27] RADIATION SAFETY CONSIDERATIONS FOR PEDIATRIC LUNG IMAGING
    Guillerman, R. Paul
    PEDIATRIC PULMONOLOGY, 2016, 51 : S17 - S18
  • [28] Use of Neurophysiological Monitoring during MR Imaging-Guided Ablation Procedures at 1.5 T: Workflow and Safety Considerations
    Treb, Kevin
    Favazza, Christopher
    Woodrum, David
    Thompson, Scott
    Hoffman, Ernest M.
    Oishi, Tatsuya
    Adamo, Daniel
    In, Myung-Ho
    Stinson, Eric
    Gorny, Krzysztof
    Lu, Aiming
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2024, 35 (11)
  • [29] Diffusion tensor MR imaging and fiber tractography: Technical considerations
    Mukherjee, P.
    Chung, S. W.
    Berman, J. I.
    Hess, C. P.
    Henry, R. G.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2008, 29 (05) : 843 - 852
  • [30] Methods and Considerations for Dynamic Analysis of Functional MR Imaging Data
    Chen, Jingyuan E.
    Rubinov, Mikail
    Chang, Catie
    NEUROIMAGING CLINICS OF NORTH AMERICA, 2017, 27 (04) : 547 - +