PHASED-ARRAY DETECTORS AND AN AUTOMATED INTENSITY-CORRECTION ALGORITHM FOR HIGH-RESOLUTION MR-IMAGING OF THE HUMAN BRAIN

被引:103
|
作者
WALD, LL [1 ]
CARVAJAL, L [1 ]
MOYHER, SE [1 ]
NELSON, SJ [1 ]
GRANT, PE [1 ]
BARKOVICH, AJ [1 ]
VIGNERON, DB [1 ]
机构
[1] UNIV CALIF SAN FRANCISCO,GRAD GRP BIOENGN,SAN FRANCISCO,CA 94143
关键词
MAGNETIC RESONANCE IMAGING; PHASED ARRAY COILS; IMAGE INTENSITY CORRECTION; BRAIN;
D O I
10.1002/mrm.1910340321
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Two- and four-coil phased array detectors were developed to increase the sensitivity and resolution of MR imaging of the human brain cortex, especially for detecting cortical dysplasias in pediatric epilepsy patients, An automated intensity correction algorithm based on an edge-completed, low-pass filtered image was used to correct the image intensity for the inhomogenous reception profile of the coils, Seven phased array coils were constructed and tested, The sensitivity of these coils was up to 600% higher at the surface of the cortex than that achieved with a conventional head coil and up to 30% greater at the center of the head. The sensitivity obtained was comparable with that of a conventional small surface coil, but extended over the larger dimensions of the array and previously inaccessible areas such as the top of the head, The advantages of the improved sensitivity are demonstrated with high resolution images of the brain.
引用
收藏
页码:433 / 439
页数:7
相关论文
共 50 条
  • [31] Modified four-coil phased array assembly for high-resolution MR imaging of the cerebellopontine angle
    Chan, JHM
    Peh, WCG
    Wong, KPC
    Luk, SH
    Tsui, EYK
    Yuen, MK
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 175 (02) : 447 - 449
  • [32] HIGH-RESOLUTION BREAST MR-IMAGING - CORRELATION WITH BREAST HISTOLOGIC CHARACTERISTICS
    HENDRICK, RE
    HOLLAND, A
    RUSS, PD
    JIN, H
    SISNEY, GA
    RADIOLOGY, 1995, 197 : 288 - 288
  • [33] HIGH-RESOLUTION MR-IMAGING EVALUATION OF VASCULAR COMPLICATIONS OF PANCREATIC TRANSPLANTATION
    KREBS, TL
    DALY, BD
    WONG, JJ
    CHOW, CC
    BARTLETT, ST
    RADIOLOGY, 1995, 197 : 378 - 378
  • [34] FEMALE PELVIS - HIGH-RESOLUTION MR-IMAGING - ANATOMIC PATHOLOGICAL CORRELATION
    STOUPIS, C
    ROS, PR
    PAWLINA, A
    TOMCZAK, RJ
    ROSS, M
    RADIOLOGY, 1995, 197 : 476 - 476
  • [35] HIGH-RESOLUTION MR-IMAGING OF THE BREAST - POTENTIAL CLINICAL-APPLICATIONS
    OREL, SG
    HOCHMAN, MG
    SCHNALL, MD
    POWELL, CM
    RADIOLOGY, 1995, 197 : 458 - 458
  • [36] A NOVEL TRANSVERSE GRADIENT COIL DESIGN FOR HIGH-RESOLUTION MR-IMAGING
    MAIER, CF
    CHU, KC
    CHRONIK, BA
    RUTT, BK
    MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (04) : 604 - 611
  • [37] High resolution phased-array coil MR imaging of pelvic lymph nodes in carcinoma of the uterus: Comparison with standard body coil imaging
    Heuck, AF
    Scheidler, JE
    Kimmig, R
    Steinborn, M
    MuellerLisse, UG
    Reiser, MF
    RADIOLOGY, 1997, 205 : 1209 - 1209
  • [38] Massive edema of the ovary: High resolution MR findings using a phased-array pelvic coil
    Kramer, LA
    Lalani, T
    Kawashima, A
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (04): : 758 - 760
  • [39] SINGLE-BREATH-HOLD VENOUS OR ARTERIAL FLOW SUPPRESSED PULMONARY VASCULAR MR-IMAGING WITH PHASED-ARRAY COILS
    FOO, TKF
    MACFALL, JR
    SOSTMAN, HD
    HAYES, CE
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (04): : 611 - 616
  • [40] Intracardiac phased-array imaging: Methods and initial clinical experience with high resolution, under blood visualization - Initial experience with intracardiac phased-array ultrasound
    Packer, DL
    Stevens, CL
    Curley, MG
    Bruce, CJ
    Miller, FA
    Khandheria, BK
    Oh, JK
    Sinak, LJ
    Seward, JB
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (03) : 509 - 516