PHASED-ARRAY DETECTORS AND AN AUTOMATED INTENSITY-CORRECTION ALGORITHM FOR HIGH-RESOLUTION MR-IMAGING OF THE HUMAN BRAIN

被引:103
|
作者
WALD, LL [1 ]
CARVAJAL, L [1 ]
MOYHER, SE [1 ]
NELSON, SJ [1 ]
GRANT, PE [1 ]
BARKOVICH, AJ [1 ]
VIGNERON, DB [1 ]
机构
[1] UNIV CALIF SAN FRANCISCO,GRAD GRP BIOENGN,SAN FRANCISCO,CA 94143
关键词
MAGNETIC RESONANCE IMAGING; PHASED ARRAY COILS; IMAGE INTENSITY CORRECTION; BRAIN;
D O I
10.1002/mrm.1910340321
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Two- and four-coil phased array detectors were developed to increase the sensitivity and resolution of MR imaging of the human brain cortex, especially for detecting cortical dysplasias in pediatric epilepsy patients, An automated intensity correction algorithm based on an edge-completed, low-pass filtered image was used to correct the image intensity for the inhomogenous reception profile of the coils, Seven phased array coils were constructed and tested, The sensitivity of these coils was up to 600% higher at the surface of the cortex than that achieved with a conventional head coil and up to 30% greater at the center of the head. The sensitivity obtained was comparable with that of a conventional small surface coil, but extended over the larger dimensions of the array and previously inaccessible areas such as the top of the head, The advantages of the improved sensitivity are demonstrated with high resolution images of the brain.
引用
收藏
页码:433 / 439
页数:7
相关论文
共 50 条
  • [1] HIGH-RESOLUTION DYNAMIC CONTRAST-ENHANCED MR-IMAGING OF THE UTERUS WITH A NEW PHASED-ARRAY MULTICOIL
    ITO, K
    HONJO, K
    FUJITA, T
    AWAYA, H
    MATSUNAGA, N
    MATTREY, RF
    RADIOLOGY, 1995, 197 : 474 - 474
  • [2] HIGH-RESOLUTION DYNAMIC CONTRAST-ENHANCED MR-IMAGING OF THE ENTIRE LIVER WITH A NEW BODY PHASED-ARRAY MULTICOIL
    ITO, K
    HONJO, K
    FUJITA, T
    AWAYA, H
    MATSUNAGA, N
    MATTREY, RF
    RADIOLOGY, 1995, 197 : 509 - 509
  • [3] Signal intensity correction of phased-array MR images
    Rettman, D
    Felmlee, JP
    Hangiandreou, NJ
    RADIOLOGY, 1996, 201 : 778 - 778
  • [4] PROTON SPECTROSCOPIC IMAGING OF THE HUMAN BRAIN USING PHASED-ARRAY DETECTORS
    WALD, LL
    MOYHER, SE
    DAY, MR
    NELSON, SJ
    VIGNERON, DB
    MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (03) : 440 - 445
  • [5] HIGH-RESOLUTION MR-IMAGING OF HUMAN ARTERIES
    MARTIN, AJ
    GOTLIEB, AI
    HENKELMAN, RM
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (01): : 93 - 100
  • [6] High resolution MR imaging of the bilateral hips with dual phased-array
    Niitsu, M
    Mishima, H
    Miyakawa, S
    Itai, Y
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (06): : 950 - 953
  • [7] NORMAL ANATOMY OF THE MEDIASTINUM AND HILUS OF THE LUNG AND TUMOR-DETECTION - FINDINGS FROM HIGH-RESOLUTION MR-IMAGING WITH A PHASED-ARRAY SURFACE COIL
    FUJITA, T
    HONJO, K
    ITO, K
    MATSUMOTO, T
    AWAYA, H
    MATSUNAGA, N
    RADIOLOGY, 1995, 197 : 527 - 527
  • [8] GADOLINIUM-ENHANCED MR-IMAGING OF UNRESECTED KIDNEY AFTER PARTIAL OR COMPLETE NEPHRECTOMY - HIGH-RESOLUTION IMAGES WITH A BODY PHASED-ARRAY COIL
    ROFSKY, NM
    WEINREB, JC
    BOSNIAK, MA
    KRINSKY, GA
    FLYER, MA
    RADIOLOGY, 1995, 197 : 147 - 147
  • [9] HIGH-RESOLUTION MR-IMAGING OF THE HIP
    BARNESS, BL
    WALKER, CW
    JONES, RW
    MOORE, TE
    MCCLELLAN, J
    GARVIN, KL
    RADIOLOGY, 1995, 197 : 469 - 469
  • [10] MR-IMAGING OF THE ABDOMEN WITH A PHASED-ARRAY MULTICOIL - PROSPECTIVE CLINICAL-EVALUATION
    CAMPEAU, NG
    JOHNSON, CD
    FELMLEE, JP
    RYDBERG, JN
    BUTTS, RK
    EHMAN, RL
    RIEDERER, SJ
    RADIOLOGY, 1995, 195 (03) : 769 - 776