FAST POINT SPREAD FUNCTION COMPUTATION FROM APERTURE FUNCTIONS IN HIGH-RESOLUTION POSITRON EMISSION TOMOGRAPHY

被引:39
|
作者
SCHMITT, D
KARUTA, B
CARRIER, C
LECOMTE, R
机构
[1] UNIV LAVAL,FAC SCI & ENGN,DEPT ELECT ENGN,QUEBEC CITY G1K 7P4,QUEBEC,CANADA
[2] UNIV SHERBROOKE,FAC MED,DEPT NUCL MED & RADIOBIOL,SHERBROOKE J1H 5N4,QUEBEC,CANADA
关键词
Manuscript received April 10; 1987; revised November 1; 1987. This work was supported by the Medical Research Council of Canada under Grant MA-8549 and by a scholarship from Le Fonds de la Recherche en SantC du QuCbec;
D O I
10.1109/42.3923
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
27
引用
收藏
页码:2 / 12
页数:11
相关论文
共 50 条
  • [31] VISUALIZATION OF DYNAMIC PENUMBRA AFTER MCA OCCLUSION IN CATS BY HIGH-RESOLUTION POSITRON EMISSION TOMOGRAPHY
    HEISS, WD
    GRAF, R
    WIENHARD, K
    LOTTGEN, J
    SAITO, R
    FUJITA, T
    ROSNER, G
    WAGNER, R
    ANNALS OF NEUROLOGY, 1994, 36 (02) : 305 - 305
  • [32] Assessment of a high-resolution candidate detector for prostate time-of-flight positron emission tomography
    Cosentino, Luigi
    Finocchiaro, Paolo
    Pappalardo, Alfio
    Garibaldi, Franco
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (11):
  • [33] HIGH-RESOLUTION POSITRON EMISSION TOMOGRAPHY WITH SOLID-STATE SCINTILLATION DETECTORS - AN INVIVO DEMONSTRATION
    MARRIOTT, C
    CADORETTE, J
    LECOMTE, R
    SCASNAR, V
    ROUSSEAU, J
    VANLIER, JE
    JOURNAL OF NUCLEAR MEDICINE, 1993, 34 (05) : P101 - P101
  • [34] DECREASING MEASUREMENT ERRORS IN POSITRON-EMISSION-TOMOGRAPHY THROUGH THE USE OF A HIGH-RESOLUTION TOMOGRAPH
    HERZOG, H
    ROTA, E
    SCHMID, A
    FEINENDEGEN, LE
    NUKLEARMEDIZIN-NUCLEAR MEDICINE, 1988, 27 (02): : 42 - 42
  • [35] DESIGN STUDIES OF 2 POSSIBLE DETECTOR BLOCKS FOR HIGH-RESOLUTION POSITRON EMISSION TOMOGRAPHY OF THE BRAIN
    ERIKSSON, L
    BOHM, C
    KESSELBERG, M
    HOLTE, S
    BERGSTROM, M
    LITTON, J
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1987, 34 (01) : 344 - 348
  • [36] A SLANTING LIGHT GUIDE ANALOG DECODING HIGH-RESOLUTION DETECTOR FOR POSITRON EMISSION TOMOGRAPHY CAMERA
    WONG, WH
    JING, M
    BENDRIEM, B
    HARTZ, R
    MULLANI, N
    GOULD, KL
    MICHEL, C
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1987, 34 (01) : 280 - 284
  • [37] Evaluation of the quantitative capability of a high-resolution positron emission tomography scanner for small animal imaging
    Fahey, FH
    Gage, HD
    Buchheimer, N
    Smith, HC
    Harkness, BA
    Williams, RC
    Bounds, MC
    Mercier, J
    Robbins, MEC
    Payne, RM
    Morton, KA
    Mach, RH
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2004, 28 (06) : 842 - 848
  • [38] ARBITRARY POINT SPREAD FUNCTIONS FROM A NARROW ANNULAR APERTURE
    COLE, TW
    OPTICA ACTA, 1980, 27 (03): : 353 - 357
  • [39] Evaluation of a high resolution positron emission tomography (PET) scanner for positron emission mammography (PEM)
    White, LL
    Ott, RJ
    Carnochan, P
    Duxbury, DM
    Bruyndonckx, P
    Tavernier, S
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 1236 - 1240
  • [40] Novel high resolution detectors for Positron Emission Tomography (PET)
    Belcari, N
    Camarda, M
    Del Guerra, A
    Herbert, DJ
    Vaiano, A
    Di Domenico, G
    Zavattini, G
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2003, 125 : 48 - 52