Carrier fluid temperature data in vertical ground heat exchangers with a varying pipe separation

被引:3
|
作者
Makasis, Nikolas [1 ]
Narsilio, Guillermo A. [1 ]
Bidarmaghz, Asal [1 ,2 ]
Johnston, Ian W. [1 ]
机构
[1] Univ Melbourne, Dept Infrastruct Engn, Parkville, Vic, Australia
[2] Univ Cambridge, Dept Engn, Cambridge CB2 1PZ, England
来源
DATA IN BRIEF | 2018年 / 18卷
基金
澳大利亚研究理事会;
关键词
D O I
10.1016/j.dib.2018.04.005
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The dataset in this article is related to shallow geothermal energy systems, which efficiently provide renewable heating and cooling to buildings, and specifically to the performance of the vertical ground heat exchangers (GHE) embedded in the ground. GHEs incorporate pipes with a circulating (carrier) fluid, exchanging heat between the ground and the building. The data show the average and inlet temperatures of the carrier fluid circulating in the pipes embedded in the GHEs (which directly relate to the performance of these systems). These temperatures were generated using detailed finite element modelling and comprise part of the daily output of various one-year simulations, accounting for numerous design parameters (including different pipe geometries) and ground conditions. An expanded explanation of the data as well as comprehensive analyses on how they were used can be found in the article titled "Ground-source heat pump systems: the effect of variable pipe separation in ground heat exchangers" (Makasis N, Narsilio GA, Bidarmaghz A, Johnston IW 2018) [1]. (C) 2018 The Authors. Published by Elsevier Inc.
引用
收藏
页码:1466 / 1470
页数:5
相关论文
共 50 条
  • [41] VERTICAL CONCENTRIC TUBE GROUND-COUPLED HEAT-EXCHANGERS
    MEI, V
    FISCHER, S
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1983, 25 (05): : 59 - 59
  • [42] Analysis of vertical ground loop heat exchangers applied to buildings in the UK
    Underwood, C. P.
    Spitler, J. D.
    BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2007, 28 (02): : 133 - 159
  • [43] Modifications to ASHRAE's sizing method for vertical ground heat exchangers
    Ahmadfard, Mohammadamin
    Bernier, Michel
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2018, 24 (07) : 803 - 817
  • [44] The influence of outer weather conditions on the modelling of vertical ground heat exchangers
    Alvarez Gomez, Pascual
    Rodriguez Maestre, Ismael
    Gonzalez Gallero, F. Javier
    Mena Balades, J. Daniel
    SUSTAINABLE CITIES DEVELOPMENT AND ENVIRONMENT PROTECTION, PTS 1-3, 2013, 361-363 : 276 - 280
  • [45] Validation of heat transfer data for fibre suspensions in coaxial pipe heat exchangers
    Kazi, S. N.
    Duffy, G. G.
    Chen, X. D.
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2012, 38 : 210 - 222
  • [46] Performance of heat pumps with direct expansion in vertical ground heat exchangers in heating mode
    De Carli, Michele
    Fiorenzato, Stefano
    Zarrella, Angelo
    ENERGY CONVERSION AND MANAGEMENT, 2015, 95 : 120 - 130
  • [47] Numerical simulation of soil freezing and associated pipe deformation in ground heat exchangers
    Wang, Youtang
    Liu, Yongqi
    Cui, Yu
    Guo, Wenchao
    Lv, Jinsheng
    GEOTHERMICS, 2018, 74 : 112 - 120
  • [48] ELECTROSTATIC HEAT PIPE DROPS FLUID TEMPERATURE
    不详
    DESIGN NEWS, 1976, 31 (05) : 22 - 23
  • [49] A simple heat and moisture transfer model to predict ground temperature for shallow ground heat exchangers
    Chalhoub, Maha
    Bernier, Michel
    Coquet, Yves
    Philippe, Mikael
    RENEWABLE ENERGY, 2017, 103 : 295 - 307
  • [50] Experimental Study of a Ground Source Heat Pump System Using Vertical Concentric Tube Ground Heat Exchangers
    Chen, Jianping
    Li, Zhongjian
    Lian, Zhiwei
    Tan, Lizheng
    ADVANCED SCIENCE LETTERS, 2011, 4 (4-5) : 1658 - 1662