FOCUSING MONOCHROMATORS FOR HIGH-ENERGY SYNCHROTRON RADIATION

被引:11
|
作者
SUORTTI, P
机构
[1] ESRF, F-38043 Grenoble Cedex
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 1992年 / 63卷 / 01期
关键词
D O I
10.1063/1.1143787
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Bent crystals are introduced as monochromators for high energy synchrotron radiation. The reflectivity of the crystal can be calculated reliably from a model where the bent crystal is approximated by a stack of lamellas, which have a gradually changing angle of reflection. The reflectivity curves of a 4 mm thick, asymmetrically cut (chi = 9.5-degrees) Si(220) crystal are measured using 150 keV radiation and varying the bending radius from 25 to 140 m. The width of the reflectivity curve is up to 50 times the Darwin width of the reflection, and the maximum reflectivity exceeds 80%. The crystal is used as a monochromator in Compton scattering measurements. The source is on the focusing circle, so that the resolution is limited essentially by the detector/analyzer. A wide bandpass, sharply focused beam is attained when the source is outside the focusing circle in the transmission geometry. In a test experiment. 10(12) photons on an area of 2 mm2 was observed. The energy band was about 4 keV centered at 40 keV. A powder diffraction pattern of a few reflections of interest was recorded by an intrinsic Ge detector, and this demonstrated that a structural transition can be followed at intervals of a few milliseconds.
引用
收藏
页码:942 / 945
页数:4
相关论文
共 50 条
  • [11] High-energy microtomography using synchrotron radiation
    Beckmann, F
    Lippmann, T
    Bonse, U
    PENETRATING RADIATION SYSTEMS AND APPLICATIONS II, 2000, 4142 : 225 - 230
  • [12] HIGH-ENERGY SYNCHROTRON-RADIATION SOURCES
    WINICK, H
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1994, 87 (1-4): : 112 - 115
  • [13] SYNCHROTRON RADIATION FROM HIGH-ENERGY ELECTRONS
    PETERSON, AM
    HOWER, GL
    JOURNAL OF GEOPHYSICAL RESEARCH, 1963, 68 (03): : 723 - +
  • [14] High resolution Bragg focusing optics for synchrotron monochromators and analyzers
    Knapp, GS
    Beno, MA
    Gofron, KJ
    HIGH HEAT FLUX AND SYNCHROTRON RADIATION BEAMLINES, 1997, 3151 : 300 - 311
  • [15] Determination of multipeak textures with high-energy synchrotron radiation
    Preusser, A
    Klein, H
    Raue, L
    Bunge, HJ
    ICOTOM 14: TEXTURES OF MATERIALS, PTS 1AND 2, 2005, 495-497 : 143 - 148
  • [16] ELLIPTIC POLARIZATION OF SYNCHROTRON RADIATION OF HIGH-ENERGY ELECTRONS
    BAGROV, VG
    NIKITIN, MM
    SOVIET ATOMIC ENERGY-USSR, 1971, 31 (03): : 1005 - &
  • [17] Application of high-energy synchrotron radiation for texture studies
    Mishin, OV
    Lauridsen, EM
    Lassen, NCK
    Brückner, G
    Tschentscher, T
    Bay, B
    Jensen, DJ
    Poulsen, HF
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2000, 33 : 364 - 371
  • [18] Probing structural chirality with high-energy synchrotron radiation
    Dyadkin, Vadim
    Wright, Jon
    Pattison, Philip
    Chernyshov, Dmitry
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2016, 49 : 918 - 922
  • [19] Texture and microstructure analysis with high-energy synchrotron radiation
    Bunge, HJ
    POWDER DIFFRACTION, 2004, 19 (01) : 60 - 64
  • [20] Nuclear fluorescence using high-energy synchrotron radiation
    Siddons, DP
    Liss, KD
    Hastings, JB
    Grübel, G
    SYNCHROTRON RADIATION INSTRUMENTATION, 2004, 705 : 1178 - 1181